Smarter Dell Technologies PowerEdge Operate 2023 Exam Preparation Starts Here: Read D-PE-OE-23 Free Dumps (Part 2, Q41-Q80) of V9.02 First

Your smarter Dell Technologies PowerEdge Operate 2023 D-PE-OE-23 exam preparation starts with DumpsBase. The D-PE-OE-23 dumps (V9.02) have been proven as a reliable resource to ensure your success. You can check the D-PE-OE-23 free dumps (Part 1, Q1-Q40) first to verify the quality. DumpsBase guarantees that your preparation is in accordance with the most recent exam objectives, regardless of whether you are a novice test taker or a certified professional seeking to enhance your Dell Technologies PowerEdge Operate 2023 certification. DumpsBase assists in bridging this gap by providing D-PE-OE-23 dumps (V9.02) that are realistic and emulate the manner and intensity of the actual exam. By utilizing these questions to practice, you can improve your test-taking strategy by directing your time, prioritizing high-yield principles, and avoiding common pitfalls. Today, we will continue to share free dumps to help you check the quality of V9.02.

Continue to read D-PE-OE-23 free dumps (Part 2, Q41-Q80) of V9.02 below:

1. Which application reduces the manual effort to update 500 Dell EMC PowerEdge R750 servers?

2. An error occurs during data transmission between the CPU and DIMM.

Which feature in a Dell PowerEdge 16G server is responsible for fixing correctable memory errors?

3. What is the minimum version of ESXi that should be used to avoid potential issues writing to the SD cards when running ESXi 7 from an IDSDM?

4. A technician needs to connect a server to a network but the network switch has only two available network ports so only two network cables can be connected. The user needs as much bandwidth as possible for their workload so the two network cables need to connect to LOM1 and LOM2.

At some point in the future a new network switch will enable additional cables to be used. The technician wants to satisfy the user requirements yet still be able to access the iDRAC without having to reconfigure the iDRAC once new cables are installed in the iDRAC Dedicated NIC.

What is the best way to configure the iDRAC?

5. Which two iDRAC license editions support enabling the Lockdown Mode feature? (Select 2)

6. In which Dell EMC PowerEdge server generation was the BOSS card introduced?

7. What image does the iDRAC9 BIOS/UEFI Recovery feature use to flash a corrupt BIOS?

8. What operation should a technician perform to ensure configuration recovery if a server must be physically replaced?

9. A Dell PowerEdge R740 server with two CPUs has six memory modules that are attached to each CPU. Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space.

What should be installed or configured?

10. When does a customer require the Service Tag of the Dell EMC PowerEdge server?

11. A technician needs to install a server with a PERC RAID controller and 24, 2.5" SAS SED drives.

The installation requires the following items to be created:

- Three equal-sized virtual disks

- Encrypted virtual disks

- A global hot spare

In addition to selecting the physical drive to be the hot spare disk, what tasks should the technician perform to set up the RAID controller?

12. Refer to the exhibit.

Match each callout to the Dell EMC PowerEdge server model shown.

13. A technician deletes the iDRAC Enterprise license on a R640 server.

Which license type is then enabled?

14. Where is the Asset Tag located on the Dell EMC PowerEdge server?

15. A server has the following configuration:

- 5x 1 TB drives configured in a RAID 5 array

- 1x 1 TB as a global hot spare

- Persistent Hot Spare Slot enabled

A user adds one additional 2 TB drive to the existing array using RAID migration.

How much disk space is available to the operating system?

16. What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?

17. What is a valid password option available from the iDRAC9 Unique ID feature?

18. An administrator is troubleshooting a no power issue on his PowerEdge server. They have confirmed the cable is "known good," and the LED on the PSU is green.

What is the next step in troubleshooting this issue?

19. A technician needs to improve overall server performance. All servers run a Dell-supported version of RedHat Linux. Turbo boost has been highly beneficial. CPU performance should be maximized, but not at the expense of power usage.

What is the most efficient way to implement these profile options?

20. What are key characteristics of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?

21. A technician creates two virtual disks and assigns a dedicated hot spare to each virtual disk. The technician also creates a global hot spare. A drive fails on the second virtual disk.

What is the result?

22. What category of error is indicated by HWC8011?

23. What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?

24. One of the servers in a datacenter is set to use the 1+1 power redundancy option with a hot spare. The server uses 1100W PSUs. An SNMP trap has been sent alerting the technician to a PSU failure.

Since this is the "hot spare" PSU, the technician chooses an available, higher capacity Titanium PSU. After replacing the PSU and connecting the power cable, the PSU indicator/handle flashes green, then turns off.

The technician has taken the following actions:

- Reseated the PSU

- Checked the firmware version

- Checked the cable connections

The PSU continues to flash green then turn off.

What should the technician do?

25. A technician needs to troubleshoot a server. The OS was operational. After an untrained person accesses the System Setup utility on the server, the OS now fails to load.

The technician reboots the server, selects F2, accesses the System Setup utility, and selects System BIOS. The technician needs to verify items in the System BIOS settings before reloading the OS.

Which two items should the technician verify? (Choose two.)

26. A technician must use the iDRAC UI to roll back a diagnostics firmware revision on a server that was updated four weeks previously. However, the replaced version cannot be found in the Firmware Rollback section on the iDRAC UI.

What is the cause of this issue?

27. A technician has a server in production. The iDRAC SEL log indicates a possible issue with DIMMs A1 and A2. Firmware is up to date.

What is the most efficient way to troubleshoot this issue?

28. A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.

What action should a technician take to help accomplish this goal?

29. What is a custom form factor mezzanine card that contains a complete NIC subsystem?

30. A technician builds a bootable ISO with Repository Manager, and then mounts the ISO via the iDRAC virtual console. After the updates have completed, the technician reboots the server to apply the updates. When reviewing the updates, the technician determines NOT all updates were applied.

What is causing this issue?

31. A technician is changing the iDRAC IP address from the static IP address 10.37.125.88 to DHCP on the technician's PowerEdge R640 that does not have a front LCD. After completing this task, they are unable to determine which IP address was given to the iDRAC and they cannot reboot the server.

What method could the technician use to determine what IP address is assigned to the iDRAC?

32. What are two ways to check on the health status of a server? (Select 2)

33. What is the result when iDRAC is in Lockdown Mode?

34. Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?

35. While working on a Dell EMC PowerEdge R640 server, a technician accidently removes two fans at the same time.

What should happen to the server?

36. An existing server is transferred to a new location. When the iDRAC port is plugged into the network, it causes an IP conflict. The technician is directed to change iDRAC settings via the LCD Front Panel Display. There is NO option to make changes.

What is the most probable cause of this issue?

37. A technician receives a repurposed PowerEdge server. After racking and cabling the server, they attempt to log into the iDRAC but cannot do so. The default login account has been disabled.

What method can be used to enable the default login account?

38. What is the maximum number of local iDRAC users that can be created?

39. A technician needs to replace a server component with orange tabs/releases.

Which two steps should the technician take to complete this task? (Choose two.)

40. A technician installs a PCIe Host Bus Adapter in a server, powers on the server, then starts the Lifecycle Controller to update the adapter's firmware. Before starting the firmware update, they examine the Current Hardware Inventory. The Host Bus Adapter is not visible so it cannot be selected for a firmware update.

How should the technician address this issue?


 