New HPE1-H05 Dumps (V8.02) for Your HPE Certifications: Read HPE1-H05 Free Dumps (Part 1, Q1-Q40) First

The Advanced HPE Compute and HPE Storage Practical Exam (HPE1-H05) is available for your HPE certifications:

  • HPE Master ASE – Compute Architect (HPE7-S01 & HPE1-H05)
  • HPE Master ASE – Storage Architect (HPE3-CL07 & HPE3-CL08 & HPE3-CL09 & HPE7-J01 & HPE1-H05)
  • HPE Master ASE – Storage Integrator Solutions (HPE3-CL07 & HPE3-CL08 & HPE3-CL09 & HPE7-J02 & HPE1-H05)
  • HPE Master ASE – Compute Integrator Solutions (HPE7-S02 & HPE1-H05)

As a generalist practical exam that covers a broad range of computing and storage skills at the intermediate level, the HPE1-H05 exam validates that you have the generalist skills and knowledge across portfolios to act as a trusted advisor for customers. Visit DumpsBase and download the newest HPE1-H05 dumps (V8.02) to prepare well. You can undoubtedly finish your Advanced HPE Compute and HPE Storage Practical Exam with impressive achievement with the help of the most recent HPE1-H05 exam questions from DumpsBase. From today, we start sharing the HPE1-H05 free dumps online to help you check the quality first.

Below are our HPE1-H05 free dumps (Part 1, Q1-Q40) of V8.02, helping you check the quality:

1. You are configuring a solution to align with security best practices. You need to secure the iLO 6 management interface on all Gen11 servers. The policy requires that the iLO does not use the default self-signed certificate.

What is the first step in the workflow to implement a CA-signed certificate?

2. During a disaster recovery simulation task, you are configuring HPE Peer Persistence for an HPE Alletra 9000 solution. You have successfully configured the Remote Copy groups and synchronous replication. However, the automatic failover test fails when you simulate a primary site storage outage.

Which critical external component is likely missing or misconfigured, preventing the system from arbitrating the split-brain scenario?

3. You are integrating HPE OneView with Microsoft Active Directory (AD). You want to map an AD Group named "HPE-Admins" to the "Infrastructure Administrator" role in OneView. You enter the group name in the directory settings, but OneView fails to authenticate users in that group. You suspect a nested group issue.

What is the constraint regarding nested groups in OneView AD integration?

4. You have configured an HPE Alletra 6000 (Nimble) array. You need to enable "Encryption" for a specific volume containing sensitive HR data. You go to the Volume Edit settings, but the option to enable encryption is greyed out.

What is the fundamental constraint of encryption on this platform?

5. You are defining an "Uplink Set" in HPE OneView for a new Synergy deployment. The uplink connects to a core switch stack that uses LACP (802.3ad). You have selected "LACP" as the requested mode in the Uplink Set. However, the status remains "Linking" or "Failed".

What is a common configuration mismatch on the upstream switch side?

6. You are designing a liquid-cooled solution using HPE ProLiant Gen11 servers with the Direct Liquid Cooling (DLC) option. The customer facilities manager asks about the maintenance requirements for the coolant. Specifically, they want to know how to top up the coolant if the levels drop in the loop within the server.

What is the correct response?

7. A customer wants to set a strict budget for their Compute usage in HPE GreenLake to prevent unexpected bills. They configure a "Budget" rule in GreenLake Central.

What happens when the actual monthly usage exceeds the defined budget threshold?

8. You run a "Firmware Compliance" report in HPE OneView for a group of servers assigned to the "Production-2023" baseline. One server shows a status of "Unknown" for its firmware compliance.

What is the most likely technical reason for this missing data?

9. An HPE Alletra 9000 controller node has failed. You replace the node. During the boot process, the new node stays in a "Safe Mode" or "Service State" and does not join the cluster. You check the console and see a message about "Cluster ID Mismatch".

What command must you run to force the new node to adopt the existing cluster's identity?

10. You are attempting to add a new HPE ProLiant Gen10 server to HPE OneView for management. The task fails with the error: "Unable to add server: The server is already managed by another management system." You know this server was previously managed by a now-decommissioned OneView appliance.

How do you resolve this "Lock" issue without physical access to the server?

11. You are auditing a SAN configuration for an HPE Alletra 9000 deployment. You notice that the administrator has configured "Single Initiator to Single Target" zoning (1:1 zoning) for all hosts.

Why is this considered a "Best Practice" over "Single Initiator to Multiple Targets" (1:Many) zoning?

12. You are planning to use HPE Online Import to migrate data from a legacy EMC VNX array to a new HPE Alletra 9000. You have configured the iSCSI connectivity between the two arrays for the data path. However, when you attempt to add the EMC VNX as a "Migration Source" in the Data Ops Manager, the connection fails. You verify the IP address is correct.

What additional connectivity is required for the "Control Path"?

13. You are configuring an "App-aware" snapshot protection policy for a set of SQL Server volumes on an HPE Alletra array using the Data Services Cloud Console. You want to ensure that the database is in a consistent state before the snapshot is taken.

What component must be installed and configured on the SQL Server host to enable this coordination?

14. A customer is using HPE iLO 6 "Automatic Recovery" feature for the System ROM (BIOS).

If the primary ROM image becomes corrupted and the server fails to post, what is the sequence of events that the "Silicon Root of Trust" initiates to recover the system?

15. You are reviewing a customer's HPE Alletra 9000 Peer Persistence configuration. The customer wants to ensure that if the primary array fails completely, the failover to the secondary array happens automatically and transparently to the hosts.

Beyond configuring the Remote Copy groups and the Quorum Witness, what specific host-side configuration is mandatory to support this transparent failover?

16. You are configuring an iSCSI connection between a Windows Server 2022 host and an HPE Alletra 6000 array. The security policy requires "Mutual CHAP" authentication. You have configured the Initiator Secret on the host.

What corresponding configuration must you perform on the Alletra 6000 to complete the bidirectional trust?

17. A customer is ordering an HPE Cray XD system for High Performance Computing. They need to manage the "Slingshot" interconnect fabric.

Which specific management tool is required to configure, monitor, and manage the Slingshot fabric controller and switches?

18. A customer wants to identify which specific "Workload" on their HPE Alletra 9000 is consuming the most power. You explain that storage arrays typically measure power at the chassis level, not the volume level.

However, using the HPE GreenLake Sustainability Dashboard, what proxy metric is used to estimate the "Power Cost" of a specific volume or application?

19. You are onsite to install a new HPE Synergy 12000 Frame. During the "Hardware Setup" phase, you connect the power cables. You notice that the "Front Panel Display" (Hood) does not power on, and the FLM link lights remain dark. You verify that the PDU is providing power.

What is the most likely installation error regarding the Frame Link Modules?

20. You are analyzing a solution for a high-density data center. The customer wants to deploy 40 HPE ProLiant DL380 Gen11 servers in a single rack. Each server has dual 350W CPUs. Using HPE Power Advisor, you calculate the total power load is 28kW. The data center only provides 20kW per rack.

What design modification allows you to fit as many servers as possible without tripping the breaker?

21. In a Hands-On practical task, you are asked to provision a new Volume on an HPE Alletra 9000 using the Data Services Cloud Console. You need to ensure the volume is exported to a specific host. You navigate to the "Block Storage" service.

What is the correct order of operations?

22. A customer needs a consolidated inventory report of all HPE ProLiant servers, Synergy frames, and Alletra storage arrays across five geographically separated data centers. Each data center has its own local HPE OneView appliance.

Which tool provides this unified, multi-site inventory view and reporting capability?

23. You are designing a storage solution for a large-scale Persistent Virtual Desktop Infrastructure (VDI) environment using VMware Horizon. The customer anticipates significant "Boot Storms" and "Login Storms" at 8:00 AM.

Which specific feature of the HPE Alletra storage architecture should you highlight as the primary mechanism for handling these random read bursts without latency spikes?

24. You are tasked with securing a new HPE ProLiant Gen11 server. The security policy requires that the server configuration (BIOS settings, iLO settings, and boot order) must be locked down to prevent any unauthorized changes by the operating system or remote administrators.

Which iLO 6 feature should you enable to apply this digital lock?

25. A customer has a 3-frame HPE Synergy ring. Frame 1 contains two Virtual Connect SE 100Gb F32 Modules (Masters). Frames 2 and 3 contain Synergy 50Gb Interconnect Link Modules (Satellites). You receive an alert that the "Logical Interconnect" is in a "Degraded" state. You investigate and find that the "Interconnect Link" cable connecting Frame 2 to Frame 1 has been accidentally severed.

What is the impact on the compute nodes in Frame 2?

26. You are designing a "Secure Boot" policy for a fleet of HPE ProLiant Gen11 servers. The customer wants to ensure that if a bootloader is signed by a Microsoft key that has been publicly revoked due to a vulnerability (like the "BlackLotus" UEFI bootkit), the server will refuse to boot it.

Which database in the Secure Boot architecture is responsible for holding these revoked signatures?

27. You are designing a solution for a customer who is highly focused on "Zero Trust" security architecture. They ask how the HPE Alletra 9000 ensures that data is secure even if a physical drive is stolen from the data center.

Which feature should you demonstrate to address this specific physical security concern?

28. You are auditing the actions performed in your HPE GreenLake cloud tenant. You specifically want to know which user deleted a critical volume named "Vol-Finance-01" last Tuesday. Where should you navigate in the Data Services Cloud Console to find this specific historical record?

29. You need to create a script to programmatically extract audit logs from HPE GreenLake Central into an external SIEM tool. You cannot use a user's email/password because the script runs as a background service.

What type of credential should you generate in the GreenLake "API Access" menu to authorize this machine-to-machine communication?

30. You are preparing to upgrade the OS version of an HPE Alletra 9000 storage array. The upgrade is designed to be online and non-disruptive. However, the pre-upgrade check warns that one of the connected ESXi hosts does not have the correct Multipathing configuration.

Why is this critical for the online upgrade process?

31. You are installing a new HPE Alletra Storage MP B10000 system consisting of 2 Controller Nodes and 2 NVMe Drive Enclosures (JBOFs).

Unlike legacy SAS-based arrays that use daisy-chaining, how must the Controller Nodes be connected to the Drive Enclosures to establish the backend storage fabric?

32. You are configuring a BOM for a customer who requires an HPE Alletra Storage MP solution. The customer's "Business Objective" is to have a completely separate, air-gapped recovery environment for Ransomware protection.

How do you translate this into a technical requirement for the "Solution Design" phase?

33. You are designing a solution for an AI inference workload that requires high-density GPU compute. You have selected the HPE ProLiant DL380a Gen11 server. The customer's data center has a strict per-rack power limit of 12kW. Using HPE Power Advisor, you determine that a fully populated rack of 10 servers would draw 16kW at peak load.

What is the most appropriate design adjustment to meet the power constraint while maximizing node count?

34. A customer is troubleshooting a Gen10 Plus server that shows "Not Connected" in the Compute Ops Management dashboard. You log into the server's iLO 5 interface locally.

Which specific iLO feature must be configured to allow the server to talk to the GreenLake Cloud?

35. A customer asks about the "Deduplication Scope" of an HPE Alletra 9000 array. They want to know if data is deduplicated only within a single volume, or across the entire array.

What is the correct architectural description?

36. You need to replace a failed Image Streamer module in a redundant pair (Ring). You insert the new physical module.

What is the correct procedure to restore redundancy and synchronize the artifacts?

37. You receive a "Wellness Alert" email from HPE InfoSight regarding an HPE ProLiant Gen10 server. The alert is titled "Driver/Firmware Compatibility Mismatch".

Unlike a standard hardware fault alert, what is the unique nature of this InfoSight wellness finding?

38. You are configuring a "Protection Policy" in the Data Services Cloud Console (DSCC) for a set of volumes. The requirement is to take a local snapshot every 15 minutes and replicate it asynchronously to a secondary array every 1 hour.

When defining the "Replication Partner" in the policy, what pre-requisite must be met for the secondary array to appear in the selection list?

39. A customer is deploying a Peer Persistence solution across two data centers (Site A and Site B). They have created the "Remote Copy Group" and replicated the volumes. However, they are confused about how to zone the hosts.

To ensure "Transparent Failover" works correctly, how must the Fibre Channel zoning be configured for a host located at Site A?

40. A customer is managing 200 Gen11 servers via HPE GreenLake for Compute Ops Management (COM). They want to ensure that all servers strictly adhere to the "Service Pack for ProLiant (SPP) 2024.03.00". If a server drifts from this version (e.g., someone manually updates a driver), they want the system to automatically flag it as "Non-Compliant" but NOT automatically reboot it.

Which policy setting in COM achieves this?


 