Since February 6, 2026, Dell upgraded the Dell PowerEdge Operate certification to V2, which validates your ability to keep PowerEdge servers performing at their best in real-world environments. Now, you need to register for the D-PE-OE-01 exam to complete this certification. DumpsBase is proud to announce the release of the latest D-PE-OE-01 dumps (V8.02) for 2026, specifically designed to help you pass the Dell PowerEdge Operate v2 exam with confidence. Our latest dumps reflect the most current exam objectives and incorporate recent changes to the PowerStore Operate certification requirements. With comprehensive coverage of all exam topics, realistic practice questions, and multiple study formats, including PDF and software, you’ll have everything you need to succeed on your first attempt.

Start reading our Dell D-PE-OE-01 free dumps (Part 1, Q1-Q40) of V8.02 below:

1. What is the maximum number of CPU cores that can be configured in a Dell EMC PowerEdge R6525 server?

2. How can a system administrator compare the currently installed hardware to the original system configuration?

3. A system admin needs to create a new iDRAC use that should NOT have privileges to change any iDRAC features or ability to configure additional users.

Which user configuration options will meet these criteria?

4. Case Study 3

A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance.

However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features.

The compute and storage environment consists of the following:

- 200 TB of Fibre Channel drives on NetApp ONTAP 7

- Environment is expected to grow 200 TB over the next three years

Which combined solution addresses the company's requirement for D@RE and U.S.SEC 17a-4(f)?

5. What does OBPAR allow on a PowerEdge MX750c?

6. A technician has a 13G system that is giving NO video to a crash cart connected to the front VGA port. The LCD is NOT reporting any errors.

The system reports ‘CPU Resetting’ messages sporadically in the lifecycle log. The iDRAC runs an Express license. The technician needs to most efficiently determine if the system is completing POST despite the video issue.

Which two steps should the technician take to perform this task? (Choose two.)

7. Which export type in iDRAC restores a Server Configuration Profile to a known baseline?

8. What is the minimum version of ESXi that should be used to avoid potential issues writing to the SD cards when running ESXi 7 from an IDSDM?

9. A user has a number of PowerEdge servers and installs OME on a remote system to monitor the servers. When attempting to discover one of the servers, the discovery process is unsuccessful. The user accesses the Troubleshooting tool to establish that the communication pathway is correct.

After entering the server iDRAC IP address, which network protocol should be selected to communicate with the iDRAC?

10. SPECIAL INSTRUCTIONS

The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the 'Review Case Study' icon shown below:

Case Study 5 - Refer to the Exhibit.

Backing up data from a Dell EMC Isilon cluster exceeds the company's backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.

Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.

The company's IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.

What advice should be provided to the team to eliminate lock contention and allow full access to users?

11. An administrator is troubleshooting a no power issue on his PowerEdge server. They have confirmed the cable is "known good," and the LED on the PSU is green.

What is the next step in troubleshooting this issue?

12. A technician needs to analyze a server that is using more power than expected. The server is part of a cluster that runs jobs between 8 AM and 5 PM. The cluster is not used at other times of the day. The server runs an unsupported OS. Performance while jobs are running is a key consideration.

Which option should the technician choose from within System Profile Settings within System Setup to address this issue?

13. A technician needs to connect a server to a network but the network switch has only two available network ports so only two network cables can be connected. The user needs as much bandwidth as possible for their workload so the two network cables need to connect to LOM1 and LOM2.

At some point in the future a new network switch will enable additional cables to be used. The technician wants to satisfy the user requirements yet still be able to access the iDRAC without having to reconfigure the iDRAC once new cables are installed in the iDRAC Dedicated NIC.

What is the best way to configure the iDRAC?

14. A technician must create a RAID array that uses striping with double parity.

Which RAID level must be used?

15. Which application reduces the manual effort to update 500 Dell EMC PowerEdge R750 servers?

16. What operation should a technician perform to ensure configuration recovery if a server must be physically replaced?

17. A server has the following configuration:

- 5x 1 TB drives configured in a RAID 5 array

- 1x 1 TB as a global hot spare

- Persistent Hot Spare Slot enabled

A user adds one additional 2 TB drive to the existing array using RAID migration.

How much disk space is available to the operating system?

18. An error occurs during data transmission between the CPU and DIMM.

Which feature in a Dell PowerEdge 16G server is responsible for fixing correctable memory errors?

19. A technician needs to initially configure a server from a bare metal condition in the following areas:

- Processor settings

- Disk configuration

- iDRAC network settings

The technician can only reboot once to achieve these tasks.

Where should the technician configure these settings? (Choose three.)

20. A technician needs to install a server with a PERC RAID controller and 24, 2.5" SAS SED drives.

The installation requires the following items to be created:

- Three equal-sized virtual disks

- Encrypted virtual disks

- A global hot spare

In addition to selecting the physical drive to be the hot spare disk, what tasks should the technician perform to set up the RAID controller?

21. Refer to the exhibit.

A system administrator wants to monitor information about the system using their smartphone and a Bluetooth connection. LED labeled 3 on the control panel is solid white.

What does the LED indicate?

22. Which three steps must a technician take prior to replacing a server component with blue tabs/release? (Choose three.)

23. Eight new servers have arrived at a datacenter. All use static IP addresses for iDRAC. The technician needs to enable these servers to contact the DHCP server on the network to obtain new IP addresses.

What method can the technician use to quickly switch to DHCP?

24. A technician is deploying a server.

What should they do once the server is fully configured and deployed?

25. Where is the Asset Tag located on the Dell EMC PowerEdge server?

26. A technician receives a new server with five drives.

They need to configure the drives based on the following requirements received from the administrator:

- Drive 0 as a single disk with no RAID

- Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5

The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.

How should the technician configure the drives?

27. 1.A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system.

What Is the cause of this Issue? Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

28. When does a customer require the Service Tag of the Dell EMC PowerEdge server?

29. A server is configured in a 1+1 power configuration with both PSUs connected to a single PDU.

Which redundancy options does this configuration supply?

30. A Dell EMC PowerEdge server logs the following CPU Machine Check error: CPU1 IERR.

What action might be required to solve the alert?

31. A technician needs to install the OS on a server remotely using iDRAC.

What is the minimum iDRAC license required to perform this task?

32. An existing server is transferred to a new location. When the iDRAC port is plugged into the network, it causes an IP conflict. The technician is directed to change iDRAC settings via the LCD Front Panel Display. There is NO option to make changes.

What is the most probable cause of this issue?

33. Which tool allows an administrator to remotely back up a PowerEdge server configuration to streamline server deployments?

34. What are two ways to check on the health status of a server? (Select 2)

35. A system administrator plans to use a remote desktop that has the DRAC tools installed to run RACADM commands.

Which two CLI options must be in the RACADM command? (Select 2)

36. A technician needs to configure the Lifecycle Controller network settings with a static IP address. A limited number of static IP addresses are available for use.

Which previously assigned IP address can also be used for the Lifecycle Controller?

37. A technician has a server in production. The iDRAC SEL log indicates a possible issue with DIMMs A1 and A2. Firmware is up to date.

What is the most efficient way to troubleshoot this issue?

38. On a PowerEdge R640 server, the System Lockdown mode has been enabled. Certain features are no longer available in the System BIOS utility or IDRAC GUI.

Which other feature is no longer available?

39. A Dell PowerEdge R740 server with two CPUs has six memory modules that are attached to each CPU. Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space.

What should be installed or configured?

40. A technician is trying to troubleshoot a server that constantly keeps raising and lowering the RPMs of the fans.

The technician investigates and finds the following:

- No errors are displayed

- No obvious log entries exist concerning temperatures

- Server cover is installed and secured

- No expansion cards are installed

What would be the quickest action plan that the technician could attempt to try to fix the issue with the fans?


 

Continue to Read D-MSS-DS-23 Free Dumps (Part 2, Q41-Q80) 2026 - Verify the Dell D-MSS-DS-23 Dumps (V12.03) Today