H19-134_V1.0-ENU Exam Dumps (V8.02): Prepare for Your Huawei HCSP-Presales-Data Center Facility (Power) V1.0 Exam Thoroughly

Earning the Huawei HCSP-Presales-Data Center Facility (Power) V1.0 certification gives you a foundational understanding of Huawei Data Center Facility products and solutions, key technologies, industry trends and challenges, and sales strategy. If you are planning to complete the certification, you can come to DumpsBase and get the latest H19-134_V1.0-ENU exam dumps (V8.02) as a preparation resource. We offer expertly verified Huawei HCSP-Presales-Data Center Facility (Power) V1.0 H19-134_V1.0-ENU exam questions in PDF and practice test software formats, allowing you to study efficiently and confidently. Today, we’re sharing free H19-134_V1.0-ENU demo questions online for you to review. After checking these questions, you’ll see why DumpsBase is trusted—whether you’re aiming to strengthen your technical knowledge or achieve certification success on the first attempt, our reliable, accurate, and user-friendly H19-134_V1.0-ENU dumps (V8.02) simplify your preparation and boost your chances of passing with excellence.

Below are the Huawei H19-134_V1.0-ENU free dumps for checking first:

1. The door types in Huawei Fusionmodule2000V3.0 include ().

2. Which of the following product models is similar in characteristics to the UPS5000 series modular UPS?

3. For a UPS5000-E 100kVA, which of the following input switches is most suitable?

4. Traditional UPS systems have fixed battery cell counts, resulting in high battery maintenance costs; the failure of a single battery may necessitate replacing the entire battery pack. The UPS5000-A features adjustable battery cell counts. What is the adjustable range?

5. When using a single RH5885 server, what is the maximum number of tens of thousands of test points that the NetEco management system can support for centralized management of multiple data centers?

6. Which of the following descriptions of the eLight feature, the smart module status indicator in FusionModule2000 v3.0, is correct?

7. What are the maximum number of cabinets within the FusionModule500 and FusionModule800 modules respectively?

8. Assume a battery specification states a discharge power of [email protected]@15min. If the system requirement is 1400W, then the number of battery packs selected is ().

9. What configuration methods does the FusionModule800 UPS support?

10. What is the static load (in kg) of the FusionModule200 cabinet?

11. Huawei Technologies Co., Ltd. is a ( ) of the GB50174-2008 standard and a () of the GB50174-2017 standard.

12. 1. What is the channel width of Huawei FusionModule2000?

13. The output power factor of UPS2000-A-(1K-3K) is ().

14. Which features are optional in the typical configuration of FusionModule500?

15. The energy-saving effect of Huawei's iCooling is ()%.

16. What is the seismic resistance rating of the Huawei Fusionmodule2000 IT cabinet?

17. When the NetEco management system intervenes in third-party devices surrounding the micro-module, what monitoring hardware is typically used for access?

18. The NetEco management system adopts a high-capacity design architecture, supporting massive device access. It supports up to ( ) tens of thousands of measurement points using a single x86 server, while maintaining smooth system operation and CPU utilization not exceeding ().

19. Which of the following descriptions about the reliability of the NetCol5000-C row-level air conditioner is incorrect?

20. The battery type supported by UPS2000-G is ().

21. Regarding the adjustable battery of the UPS5000-E, when one battery fails, at least () batteries need to be removed. Then, set the corresponding number of batteries on the monitoring panel.

22. Considering low UPS system load conditions, the UPS5000-E is designed with an intelligent sleep function. This function can improve the system load rate and maintain efficient system operation. When the UPS5000E is in intelligent sleep mode, how many power modules are redundant?

23. The UPS system is equipped with 32 12V batteries. The UPS's set float charge voltage is ().

24. Firefighting measures that can be adopted for Class A computer rooms include ().

25. FusionModule1000A V2R3 version 40 - foot IT solution with N+X redundancy, featuring IBATTWERY configuration; how many IT racks can it provide?

26. In which of the following regions does the AHU solution perform the worst?

27. Which of the following features is a standard feature of the NETCOL8000-C air conditioner?

28. UPS5000-A/E models above 400KVA are available in standard and enhanced versions. The standard version comes standard with a () disconnect switch.

29. The UPS5000-E can easily realize a 2N power supply system by simply selecting (), and the operation is simple and convenient.

30. What is the maximum power consumption of the IT cabinets for FusionModule500 and FusionModule800?

31. When selecting both the expansion dry contact card and the backflow protection card for the UPS5000-E, which of the following options should also be selected?

32. The operating interface of the UPS2000-G 6-20k main unit is (), which can display the system status in real time.

33. The UPS5000-E features a wide voltage and frequency input range, making it suitable for harsh power grid environments and extending battery life. What is the full-load input voltage range of the UPS5000-E?

under full load?

34. Which of the following descriptions of the iMiManager feature in FusionModule2000 v3.0 is incorrect?

35. What are the supported incoming line methods for the UPS5000-A-400/500K?

36. A project requires the management system to connect to one generator set, two smart meters (of the same model), and two precision air conditioners (of the same model) from a third party. How many third-party device access fees should the management system report?

37. What sensor does the FusionModule2000 use to detect if the air conditioner is leaking water?

38. Which of the following UPS systems does not have a neutral line?

39. The UPS500-A-400/500K can support a maximum of () parallel operation, and has good scalability.

40. The power supply architecture adopted by the new row-level half-cabinet chilled water system is ().

41. What pole circuit breaker is typically selected for the external maintenance bypass of a UPS system?

42. What is the lowest outdoor ambient temperature that the FusionModule800 air conditioner can support?

43. What power input methods does the FusionModule800 support?

44. Protection level of PDU8000 precision distribution cabinet ().

45. Which of the following humidification methods has the lowest energy consumption?

46. The humidifier type used in the NetCol5000-C032H intelligent temperature control product for chilled water is ().

47. When configuring temperature control products, if the project site temperature is between -10 and 30 degrees Celsius, which of the following operating conditions should be preferred?

48. When the length of a rack () arranged in a row exceeds the length of two channels, additional channels should be added () between the two channels. Channels should be provided at both ends. When the distance between two channels exceeds the length of two channels, additional channels should be added directly between the two channels.

49. The rated voltage of a single cell in a VRLA battery is not ().

50. The NetCoL5000-A042H full-cabinet row-level air-cooled inverter precision air conditioner's light-load dehumidification function supports stable dehumidification under the lowest () load, which can solve the problem of frequent start-stop and failure to dehumidify in low-load, high-humidity environments, reducing the risk of condensation in the computer room.


 