{"id":82702,"date":"2024-06-21T07:38:58","date_gmt":"2024-06-21T07:38:58","guid":{"rendered":"https:\/\/www.dumpsbase.com\/freedumps\/?p=82702"},"modified":"2024-06-21T07:39:04","modified_gmt":"2024-06-21T07:39:04","slug":"updated-ns0-520-dumps-v13-02-boost-your-netapp-certified-implementation-engineer-san-ontap-exam-preparation","status":"publish","type":"post","link":"https:\/\/www.dumpsbase.com\/freedumps\/updated-ns0-520-dumps-v13-02-boost-your-netapp-certified-implementation-engineer-san-ontap-exam-preparation.html","title":{"rendered":"Updated NS0-520 Dumps (V13.02) &#8211; Boost Your NetApp Certified Implementation Engineer &#8211; SAN, ONTAP Exam Preparation"},"content":{"rendered":"\n<p>The NS0-520 dumps (V13.02) are available on DumpsBase, ensuring you get the most updated exam questions and answers that cover the NetApp NS0-520 exam topics effectively. These NS0-520 updated dumps not only make your preparation more authentic but also get you acquainted with the best solutions provided by experts. This can help you prepare for the NetApp Certified Implementation Engineer &#8211; SAN, ONTAP certification exam with the NS0-520 updated exam questions and complete your tasks on time while gaining extensive knowledge from the NS0-520 preparation dumps. DumpsBase offers you numerous opportunities to coordinate your Network Appliance NS0-520 exam preparation with the most updated NS0-520 exam dumps (V13.02). All you need to do is visit DumpsBase, prepare appropriately with the NetApp NS0-520 exam dumps, and seize the opportunity to progress at the first appearance.<\/p>\n<h2>NetApp NCIE &#8211; SAN, ONTAP Certification Exam <em><span style=\"background-color: #00ffff;\">NS0-520 Free Dumps<\/span><\/em><\/h2>\n<script>\n\t  window.fbAsyncInit = function() {\n\t    FB.init({\n\t      appId            : '622169541470367',\n\t      autoLogAppEvents : true,\n\t      xfbml            : true,\n\t      version          : 'v3.1'\n\t    });\n\t  };\n\t\n\t  (function(d, s, id){\n\t     var js, fjs = d.getElementsByTagName(s)[0];\n\t     if (d.getElementById(id)) {return;}\n\t     js = d.createElement(s); js.id = id;\n\t     js.src = \"https:\/\/connect.facebook.net\/en_US\/sdk.js\";\n\t     fjs.parentNode.insertBefore(js, fjs);\n\t   }(document, 'script', 'facebook-jssdk'));\n\t<\/script><script type=\"text\/javascript\" >\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \nif(!window.jQuery) alert(\"The important jQuery library is not properly loaded in your site. Your WordPress theme is probably missing the essential wp_head() call. You can switch to another theme and you will see that the plugin works fine and this notice disappears. If you are still not sure what to do you can contact us for help.\");\n});\n<\/script>  \n  \n<div  id=\"watupro_quiz\" class=\"quiz-area single-page-quiz\">\n<p id=\"submittingExam8763\" style=\"display:none;text-align:center;\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\"><\/p>\n\n<div class=\"watupro-exam-description\" id=\"description-quiz-8763\"><\/div>\n\n<form action=\"\" method=\"post\" class=\"quiz-form\" id=\"quiz-8763\"  enctype=\"multipart\/form-data\" >\n<div class='watu-question ' id='question-1' style=';'><div id='questionWrap-1'  class='   watupro-question-id-341273'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>1. <\/span>You are asked to serve iSCSI LUNs in an existing SVM on your AFF A220 using ONTAP 9.5. You verified that the iSCSI license is configured on your cluster and that the iSCSI protocol is enabled. <br \/>\r<br><br><img decoding=\"async\" width=531 height=127 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image001-41.jpg\"><br><br \/>\r<br>Referring to the exhibit, what is needed to allow hosts to log into the iSCSI target?<\/div><input type='hidden' name='question_id[]' id='qID_1' value='341273' \/><input type='hidden' id='answerType341273' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341273[]' id='answer-id-1334939' class='answer   answerof-341273 ' value='1334939'   \/><label for='answer-id-1334939' id='answer-label-1334939' class=' answer'><span>Create new LIFs with the iSCSI data protocol.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341273[]' id='answer-id-1334940' class='answer   answerof-341273 ' value='1334940'   \/><label for='answer-id-1334940' id='answer-label-1334940' class=' answer'><span>Create new igroups with the host IQNs.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341273[]' id='answer-id-1334941' class='answer   answerof-341273 ' value='1334941'   \/><label for='answer-id-1334941' id='answer-label-1334941' class=' answer'><span>Add iSCSI to the data protocol of the existing LIFs.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341273[]' id='answer-id-1334942' class='answer   answerof-341273 ' value='1334942'   \/><label for='answer-id-1334942' id='answer-label-1334942' class=' answer'><span>Map LUNs to the igroups.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-2' style=';'><div id='questionWrap-2'  class='   watupro-question-id-341274'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>2. <\/span>You are testing iSCSI LUN failover across a 4-node FAS9000 fabric-attached MetroCluster configuration. <br \/>\r<br>In this scenario, which front end configuration is required for non-disruptive host LUN failover between sites?<\/div><input type='hidden' name='question_id[]' id='qID_2' value='341274' \/><input type='hidden' id='answerType341274' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341274[]' id='answer-id-1334943' class='answer   answerof-341274 ' value='1334943'   \/><label for='answer-id-1334943' id='answer-label-1334943' class=' answer'><span>an interclassed LIF<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341274[]' id='answer-id-1334944' class='answer   answerof-341274 ' value='1334944'   \/><label for='answer-id-1334944' id='answer-label-1334944' class=' answer'><span>a stretched Layer 2 network<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341274[]' id='answer-id-1334945' class='answer   answerof-341274 ' value='1334945'   \/><label for='answer-id-1334945' id='answer-label-1334945' class=' answer'><span>Ipv6<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341274[]' id='answer-id-1334946' class='answer   answerof-341274 ' value='1334946'   \/><label for='answer-id-1334946' id='answer-label-1334946' class=' answer'><span>a stretched VSAN<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-3' style=';'><div id='questionWrap-3'  class='   watupro-question-id-341275'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>3. <\/span>Referring to the exhibit, which two pairs of ports are currently configurable as FC SAN LIFs? (Choose two.) <br \/>\r<br><br><img decoding=\"async\" width=649 height=236 id=\"\u56fe\u7247 25\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image002-44.jpg\"><br><\/div><input type='hidden' name='question_id[]' id='qID_3' value='341275' \/><input type='hidden' id='answerType341275' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341275[]' id='answer-id-1334947' class='answer   answerof-341275 ' value='1334947'   \/><label for='answer-id-1334947' id='answer-label-1334947' class=' answer'><span>01b, 0h<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341275[]' id='answer-id-1334948' class='answer   answerof-341275 ' value='1334948'   \/><label for='answer-id-1334948' id='answer-label-1334948' class=' answer'><span>01a, 0g<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341275[]' id='answer-id-1334949' class='answer   answerof-341275 ' value='1334949'   \/><label for='answer-id-1334949' id='answer-label-1334949' class=' answer'><span>01a, 0h<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341275[]' id='answer-id-1334950' class='answer   answerof-341275 ' value='1334950'   \/><label for='answer-id-1334950' id='answer-label-1334950' class=' answer'><span>01b, 0g<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-4' style=';'><div id='questionWrap-4'  class='   watupro-question-id-341276'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>4. <\/span>You have a 4-node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that you can save 6% of storage space. AFF A300 volumes that use under 5000 IOPS are moved to a FAS8200 using the volume move command. <br \/>\r<br>In this scenario, what happens to the data after the volume is moved? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_4' value='341276' \/><input type='hidden' id='answerType341276' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341276[]' id='answer-id-1334951' class='answer   answerof-341276 ' value='1334951'   \/><label for='answer-id-1334951' id='answer-label-1334951' class=' answer'><span>The new written data is not compacted.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341276[]' id='answer-id-1334952' class='answer   answerof-341276 ' value='1334952'   \/><label for='answer-id-1334952' id='answer-label-1334952' class=' answer'><span>The existing data is compacted.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341276[]' id='answer-id-1334953' class='answer   answerof-341276 ' value='1334953'   \/><label for='answer-id-1334953' id='answer-label-1334953' class=' answer'><span>The new written data is compacted.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341276[]' id='answer-id-1334954' class='answer   answerof-341276 ' value='1334954'   \/><label for='answer-id-1334954' id='answer-label-1334954' class=' answer'><span>The existing data is not compacted.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-5' style=';'><div id='questionWrap-5'  class='   watupro-question-id-341277'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>5. <\/span>You have a requirement to serve LUNs with under 200 microsecond latency using local server lass memory. You also are required to use a shared SAN. <br \/>\r<br><br><img decoding=\"async\" width=649 height=401 id=\"\u56fe\u7247 21\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image003-41.jpg\"><br><br \/>\r<br>Using MAX Data as shown in the exhibit, which two LUN access protocols are supported with this solution? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_5' value='341277' \/><input type='hidden' id='answerType341277' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341277[]' id='answer-id-1334955' class='answer   answerof-341277 ' value='1334955'   \/><label for='answer-id-1334955' id='answer-label-1334955' class=' answer'><span>iSCSI<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341277[]' id='answer-id-1334956' class='answer   answerof-341277 ' value='1334956'   \/><label for='answer-id-1334956' id='answer-label-1334956' class=' answer'><span>FCoE<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341277[]' id='answer-id-1334957' class='answer   answerof-341277 ' value='1334957'   \/><label for='answer-id-1334957' id='answer-label-1334957' class=' answer'><span>FC<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341277[]' id='answer-id-1334958' class='answer   answerof-341277 ' value='1334958'   \/><label for='answer-id-1334958' id='answer-label-1334958' class=' answer'><span>NVMe<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-6' style=';'><div id='questionWrap-6'  class='   watupro-question-id-341278'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>6. <\/span>A company has 20 ESX hosts. Ten of the hosts are connected using FC, and the rest are connected over iSCSI. The FC host HBA queue depth is set to 32, and the iSCSI LUN queue depth is set to 64. The FC hosts are random connectivity issues. <br \/>\r<br>In this scenario, what would be the reason for the disconnects?<\/div><input type='hidden' name='question_id[]' id='qID_6' value='341278' \/><input type='hidden' id='answerType341278' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341278[]' id='answer-id-1334959' class='answer   answerof-341278 ' value='1334959'   \/><label for='answer-id-1334959' id='answer-label-1334959' class=' answer'><span>The FC host has a lower queue depth.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341278[]' id='answer-id-1334960' class='answer   answerof-341278 ' value='1334960'   \/><label for='answer-id-1334960' id='answer-label-1334960' class=' answer'><span>According to the IMT, unsupported HBA firmware is in use.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341278[]' id='answer-id-1334961' class='answer   answerof-341278 ' value='1334961'   \/><label for='answer-id-1334961' id='answer-label-1334961' class=' answer'><span>All of the hosts are part of the same cluster.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341278[]' id='answer-id-1334962' class='answer   answerof-341278 ' value='1334962'   \/><label for='answer-id-1334962' id='answer-label-1334962' class=' answer'><span>The queue depth is not consistent across the cluster.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-7' style=';'><div id='questionWrap-7'  class='   watupro-question-id-341279'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>7. <\/span>You want to ensure maximum performance of iSCSI LUNs on an AFF A220. <br \/>\r<br>In this scenario, which two actions will accomplish this task? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_7' value='341279' \/><input type='hidden' id='answerType341279' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341279[]' id='answer-id-1334963' class='answer   answerof-341279 ' value='1334963'   \/><label for='answer-id-1334963' id='answer-label-1334963' class=' answer'><span>Disable flow control.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341279[]' id='answer-id-1334964' class='answer   answerof-341279 ' value='1334964'   \/><label for='answer-id-1334964' id='answer-label-1334964' class=' answer'><span>Configure virtual LAN (VLAN).<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341279[]' id='answer-id-1334965' class='answer   answerof-341279 ' value='1334965'   \/><label for='answer-id-1334965' id='answer-label-1334965' class=' answer'><span>Enable flow control.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341279[]' id='answer-id-1334966' class='answer   answerof-341279 ' value='1334966'   \/><label for='answer-id-1334966' id='answer-label-1334966' class=' answer'><span>Enable jumbo frames.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-8' style=';'><div id='questionWrap-8'  class='   watupro-question-id-341280'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>8. <\/span>You are provisioning storage to an ESX host that uses iSCSI. <br \/>\r<br>According to NetApp best practice, which three actions accomplish this task? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_8' value='341280' \/><input type='hidden' id='answerType341280' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341280[]' id='answer-id-1334967' class='answer   answerof-341280 ' value='1334967'   \/><label for='answer-id-1334967' id='answer-label-1334967' class=' answer'><span>Enable the iSCSI service.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341280[]' id='answer-id-1334968' class='answer   answerof-341280 ' value='1334968'   \/><label for='answer-id-1334968' id='answer-label-1334968' class=' answer'><span>Bind the iSCSI ports to the software iSCSI adapter.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341280[]' id='answer-id-1334969' class='answer   answerof-341280 ' value='1334969'   \/><label for='answer-id-1334969' id='answer-label-1334969' class=' answer'><span>Install Virtual Storage Console (VSC) for VMware.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341280[]' id='answer-id-1334970' class='answer   answerof-341280 ' value='1334970'   \/><label for='answer-id-1334970' id='answer-label-1334970' class=' answer'><span>Enable BGP on the switch.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341280[]' id='answer-id-1334971' class='answer   answerof-341280 ' value='1334971'   \/><label for='answer-id-1334971' id='answer-label-1334971' class=' answer'><span>Configure MTU 1500 on the switch.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-9' style=';'><div id='questionWrap-9'  class='   watupro-question-id-341281'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>9. <\/span>A customer has an AFF A700 connected to a Cisco switch and has verified connectivity but cannot see any LUNs. The customer issued the run -node scaling-01 -command fop topology show command to verify the connection. <br \/>\r<br><br><img decoding=\"async\" width=649 height=304 id=\"\u56fe\u7247 36\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image004-37.jpg\"><br><br \/>\r<br>Referring to the exhibit, what needs to be enabled on the Cisco switch?<\/div><input type='hidden' name='question_id[]' id='qID_9' value='341281' \/><input type='hidden' id='answerType341281' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341281[]' id='answer-id-1334972' class='answer   answerof-341281 ' value='1334972'   \/><label for='answer-id-1334972' id='answer-label-1334972' class=' answer'><span>Trunking needs to be enabled.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341281[]' id='answer-id-1334973' class='answer   answerof-341281 ' value='1334973'   \/><label for='answer-id-1334973' id='answer-label-1334973' class=' answer'><span>VSAN needs to be enabled.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341281[]' id='answer-id-1334974' class='answer   answerof-341281 ' value='1334974'   \/><label for='answer-id-1334974' id='answer-label-1334974' class=' answer'><span>NPIV needs to be enabled.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341281[]' id='answer-id-1334975' class='answer   answerof-341281 ' value='1334975'   \/><label for='answer-id-1334975' id='answer-label-1334975' class=' answer'><span>VFC needs to be enabled.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-10' style=';'><div id='questionWrap-10'  class='   watupro-question-id-341282'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>10. <\/span>A customer is using both FC and NVMe in a cluster. The customer needs to do some work on AFF_1. <br \/>\r<br><br><img decoding=\"async\" width=651 height=210 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image005-33.jpg\"><br><br \/>\r<br>Referring to the exhibit, what will happen?<\/div><input type='hidden' name='question_id[]' id='qID_10' value='341282' \/><input type='hidden' id='answerType341282' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341282[]' id='answer-id-1334976' class='answer   answerof-341282 ' value='1334976'   \/><label for='answer-id-1334976' id='answer-label-1334976' class=' answer'><span>The NVMe namespaces on AFF_2 will be available after takeover of AFF_1.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341282[]' id='answer-id-1334977' class='answer   answerof-341282 ' value='1334977'   \/><label for='answer-id-1334977' id='answer-label-1334977' class=' answer'><span>The FC LUNs that use cluster interconnect to access the LUNs on AFF_1 will be unavailable after failover.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341282[]' id='answer-id-1334978' class='answer   answerof-341282 ' value='1334978'   \/><label for='answer-id-1334978' id='answer-label-1334978' class=' answer'><span>The FC LUNs on node AFF_2 will be unavailable after failover of AFF_1.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341282[]' id='answer-id-1334979' class='answer   answerof-341282 ' value='1334979'   \/><label for='answer-id-1334979' id='answer-label-1334979' class=' answer'><span>The NVMe namespaces on AFF_1 will be unavailable after takeover by AFF_2.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-11' style=';'><div id='questionWrap-11'  class='   watupro-question-id-341283'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>11. <\/span>You have an existing 2-node AFF A300 cluster with premium bundle licensing applied. You need to have consistently low front end latency, and have determined that NVMe satisfies this requirement. <br \/>\r<br><br><img decoding=\"async\" width=649 height=204 id=\"\u56fe\u7247 58\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image006-28.jpg\"><br><br \/>\r<br>Referring to the exhibit, which two actions would accomplish this task? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_11' value='341283' \/><input type='hidden' id='answerType341283' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341283[]' id='answer-id-1334980' class='answer   answerof-341283 ' value='1334980'   \/><label for='answer-id-1334980' id='answer-label-1334980' class=' answer'><span>Add a UTA2 adapter to each of the two AFF A300 nodes.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341283[]' id='answer-id-1334981' class='answer   answerof-341283 ' value='1334981'   \/><label for='answer-id-1334981' id='answer-label-1334981' class=' answer'><span>Add a 32 GB FC HBA to each of the two AFF A300 nodes.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341283[]' id='answer-id-1334982' class='answer   answerof-341283 ' value='1334982'   \/><label for='answer-id-1334982' id='answer-label-1334982' class=' answer'><span>Apply the license for FC<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341283[]' id='answer-id-1334983' class='answer   answerof-341283 ' value='1334983'   \/><label for='answer-id-1334983' id='answer-label-1334983' class=' answer'><span>Apply the license for NVMe.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-12' style=';'><div id='questionWrap-12'  class='   watupro-question-id-341284'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>12. <\/span>You have a thin-provisioned LUN that was created by using the lun create -vserver vs1 C path \/vol\/vol1\/lun1 -size 500G -ostype windows 2008 -space-reserve disabled -space-allocation disabled command. You verify that your Windows 2016 host reports 200 GB free on lun1. However, lun1 shows 0 bytes free on the storage cluster. <br \/>\r<br>What should you do to solve this problem?<\/div><input type='hidden' name='question_id[]' id='qID_12' value='341284' \/><input type='hidden' id='answerType341284' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341284[]' id='answer-id-1334984' class='answer   answerof-341284 ' value='1334984'   \/><label for='answer-id-1334984' id='answer-label-1334984' class=' answer'><span>Change the LUN -space-allocation parameter to enabled.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341284[]' id='answer-id-1334985' class='answer   answerof-341284 ' value='1334985'   \/><label for='answer-id-1334985' id='answer-label-1334985' class=' answer'><span>Change the LUN -ostype parameter to windows_gpt.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341284[]' id='answer-id-1334986' class='answer   answerof-341284 ' value='1334986'   \/><label for='answer-id-1334986' id='answer-label-1334986' class=' answer'><span>Change the LUN -space-reserve parameter to enabled.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341284[]' id='answer-id-1334987' class='answer   answerof-341284 ' value='1334987'   \/><label for='answer-id-1334987' id='answer-label-1334987' class=' answer'><span>Rescan the LUN disk in your Windows host so that it will notify NetApp about the free space.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-13' style=';'><div id='questionWrap-13'  class='   watupro-question-id-341285'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>13. <\/span>Referring to the exhibit, what happens when you change the type for port 1a from target to initiator? <br \/>\r<br><br><img decoding=\"async\" width=651 height=198 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image007-29.jpg\"><br><\/div><input type='hidden' name='question_id[]' id='qID_13' value='341285' \/><input type='hidden' id='answerType341285' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341285[]' id='answer-id-1334988' class='answer   answerof-341285 ' value='1334988'   \/><label for='answer-id-1334988' id='answer-label-1334988' class=' answer'><span>The port type for 1a changes to initiator, and you must reboot the controller for the changes to take effect.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341285[]' id='answer-id-1334989' class='answer   answerof-341285 ' value='1334989'   \/><label for='answer-id-1334989' id='answer-label-1334989' class=' answer'><span>You receive an error message that you must take ports 1a and 1b offline before you can change the type.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341285[]' id='answer-id-1334990' class='answer   answerof-341285 ' value='1334990'   \/><label for='answer-id-1334990' id='answer-label-1334990' class=' answer'><span>The port type for 1a and 1b changes to initiator, and you must reboot the controller for the changes to take effect.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341285[]' id='answer-id-1334991' class='answer   answerof-341285 ' value='1334991'   \/><label for='answer-id-1334991' id='answer-label-1334991' class=' answer'><span>You receive an error message that you must take the port 1a offline before you can change the type.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-14' style=';'><div id='questionWrap-14'  class='   watupro-question-id-341286'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>14. <\/span>Which two features does Assymmetric Namespase Access (ANA) support? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_14' value='341286' \/><input type='hidden' id='answerType341286' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341286[]' id='answer-id-1334992' class='answer   answerof-341286 ' value='1334992'   \/><label for='answer-id-1334992' id='answer-label-1334992' class=' answer'><span>multipathing<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341286[]' id='answer-id-1334993' class='answer   answerof-341286 ' value='1334993'   \/><label for='answer-id-1334993' id='answer-label-1334993' class=' answer'><span>LUN masking<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341286[]' id='answer-id-1334994' class='answer   answerof-341286 ' value='1334994'   \/><label for='answer-id-1334994' id='answer-label-1334994' class=' answer'><span>LUN hosting<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341286[]' id='answer-id-1334995' class='answer   answerof-341286 ' value='1334995'   \/><label for='answer-id-1334995' id='answer-label-1334995' class=' answer'><span>path management<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-15' style=';'><div id='questionWrap-15'  class='   watupro-question-id-341287'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>15. <\/span>A customer that is using an AFF A220 has a problem with a host for a new FC LUN. Other LUNs on the same SVM are working properly. This LUN is not visible on the host. <br \/>\r<br>Which configuration does the customer need to verify in their solution?<\/div><input type='hidden' name='question_id[]' id='qID_15' value='341287' \/><input type='hidden' id='answerType341287' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341287[]' id='answer-id-1334996' class='answer   answerof-341287 ' value='1334996'   \/><label for='answer-id-1334996' id='answer-label-1334996' class=' answer'><span>LUN mapping with igroup<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341287[]' id='answer-id-1334997' class='answer   answerof-341287 ' value='1334997'   \/><label for='answer-id-1334997' id='answer-label-1334997' class=' answer'><span>host HBA speed settings<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341287[]' id='answer-id-1334998' class='answer   answerof-341287 ' value='1334998'   \/><label for='answer-id-1334998' id='answer-label-1334998' class=' answer'><span>FC target port setting on NetApp node<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341287[]' id='answer-id-1334999' class='answer   answerof-341287 ' value='1334999'   \/><label for='answer-id-1334999' id='answer-label-1334999' class=' answer'><span>FC switch zoning<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-16' style=';'><div id='questionWrap-16'  class='   watupro-question-id-341288'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>16. <\/span>A customer has an existing 8-node cluster that consists of six FAS2650 nodes and two FAS2554 nodes. The customer wants to expand the cluster by adding two AFF A220 nodes. <br \/>\r<br>Which resource would be used to determine whether this configuration is supported?<\/div><input type='hidden' name='question_id[]' id='qID_16' value='341288' \/><input type='hidden' id='answerType341288' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341288[]' id='answer-id-1335000' class='answer   answerof-341288 ' value='1335000'   \/><label for='answer-id-1335000' id='answer-label-1335000' class=' answer'><span>Interoperability Matrix Tool (IMT)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341288[]' id='answer-id-1335001' class='answer   answerof-341288 ' value='1335001'   \/><label for='answer-id-1335001' id='answer-label-1335001' class=' answer'><span>Config Advisor<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341288[]' id='answer-id-1335002' class='answer   answerof-341288 ' value='1335002'   \/><label for='answer-id-1335002' id='answer-label-1335002' class=' answer'><span>OneCollect<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341288[]' id='answer-id-1335003' class='answer   answerof-341288 ' value='1335003'   \/><label for='answer-id-1335003' id='answer-label-1335003' class=' answer'><span>Hardware Universe (HWU)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-17' style=';'><div id='questionWrap-17'  class='   watupro-question-id-341289'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>17. <\/span>You deployed a new SVM for FC access, and you used the vserver fcr, create -vserver svm1 - status-admin up command to enable FC service on the SVM. You then created the LIFs for the FC protocol. <br \/>\r<br>When you review the status of the LIFs, they show that the admin status is up, but the operational status is down. You have already verified that the ports are physically connected. <br \/>\r<br>In this scenario, what is the next step to bring the LIFs up?<\/div><input type='hidden' name='question_id[]' id='qID_17' value='341289' \/><input type='hidden' id='answerType341289' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341289[]' id='answer-id-1335004' class='answer   answerof-341289 ' value='1335004'   \/><label for='answer-id-1335004' id='answer-label-1335004' class=' answer'><span>Use the network interface modify command to change the operational status of the LIFs.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341289[]' id='answer-id-1335005' class='answer   answerof-341289 ' value='1335005'   \/><label for='answer-id-1335005' id='answer-label-1335005' class=' answer'><span>Create at least one zone that contains your SVM LIF WWPNs and an initiator.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341289[]' id='answer-id-1335006' class='answer   answerof-341289 ' value='1335006'   \/><label for='answer-id-1335006' id='answer-label-1335006' class=' answer'><span>Verify that an FC license is applied on your system.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341289[]' id='answer-id-1335007' class='answer   answerof-341289 ' value='1335007'   \/><label for='answer-id-1335007' id='answer-label-1335007' class=' answer'><span>Disable the SAN switch port where your NetApp storage is connected.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-18' style=';'><div id='questionWrap-18'  class='   watupro-question-id-341290'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>18. <\/span>A customer wants to add a 2-port, 32 Gb FC card to support NVMe in an AFF A700 2-node cluster. Currently, there are cards in slots 1, 2, 4, 6, 8, and 9. <br \/>\r<br><br><img decoding=\"async\" width=651 height=248 id=\"\u56fe\u7247 55\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image008-27.jpg\"><br><br \/>\r<br>Referring to the exhibit, what is the number of the slot that should be used?<\/div><input type='hidden' name='question_id[]' id='qID_18' value='341290' \/><input type='hidden' id='answerType341290' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341290[]' id='answer-id-1335008' class='answer   answerof-341290 ' value='1335008'   \/><label for='answer-id-1335008' id='answer-label-1335008' class=' answer'><span>10<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341290[]' id='answer-id-1335009' class='answer   answerof-341290 ' value='1335009'   \/><label for='answer-id-1335009' id='answer-label-1335009' class=' answer'><span>3<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341290[]' id='answer-id-1335010' class='answer   answerof-341290 ' value='1335010'   \/><label for='answer-id-1335010' id='answer-label-1335010' class=' answer'><span>5<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341290[]' id='answer-id-1335011' class='answer   answerof-341290 ' value='1335011'   \/><label for='answer-id-1335011' id='answer-label-1335011' class=' answer'><span>7<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-19' style=';'><div id='questionWrap-19'  class='   watupro-question-id-341291'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>19. <\/span>Referring to the exhibit, which two elements are required for NVMe host access with ONTAP 9.5 and using supported AFF nodes? (Choose two.) <br \/>\r<br><br><img decoding=\"async\" width=616 height=441 id=\"\u56fe\u7247 38\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image009-25.jpg\"><br><\/div><input type='hidden' name='question_id[]' id='qID_19' value='341291' \/><input type='hidden' id='answerType341291' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341291[]' id='answer-id-1335012' class='answer   answerof-341291 ' value='1335012'   \/><label for='answer-id-1335012' id='answer-label-1335012' class=' answer'><span>You need 16 Gb FC HBAs installed in the AFF nodes.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341291[]' id='answer-id-1335013' class='answer   answerof-341291 ' value='1335013'   \/><label for='answer-id-1335013' id='answer-label-1335013' class=' answer'><span>You must have the license installed for NVMe support in the cluster.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341291[]' id='answer-id-1335014' class='answer   answerof-341291 ' value='1335014'   \/><label for='answer-id-1335014' id='answer-label-1335014' class=' answer'><span>You must have the license installed for FC support in the cluster.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341291[]' id='answer-id-1335015' class='answer   answerof-341291 ' value='1335015'   \/><label for='answer-id-1335015' id='answer-label-1335015' class=' answer'><span>You need 32 Gb FC HBAs installed in the AFF nodes.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-20' style=';'><div id='questionWrap-20'  class='   watupro-question-id-341292'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>20. <\/span>A customer is required to encrypt iSCSI traffic across their public network. <br \/>\r<br>In this scenario, which method will accomplish this task?<\/div><input type='hidden' name='question_id[]' id='qID_20' value='341292' \/><input type='hidden' id='answerType341292' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341292[]' id='answer-id-1335016' class='answer   answerof-341292 ' value='1335016'   \/><label for='answer-id-1335016' id='answer-label-1335016' class=' answer'><span>dot1q<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341292[]' id='answer-id-1335017' class='answer   answerof-341292 ' value='1335017'   \/><label for='answer-id-1335017' id='answer-label-1335017' class=' answer'><span>IPsec<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341292[]' id='answer-id-1335018' class='answer   answerof-341292 ' value='1335018'   \/><label for='answer-id-1335018' id='answer-label-1335018' class=' answer'><span>NVMe<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341292[]' id='answer-id-1335019' class='answer   answerof-341292 ' value='1335019'   \/><label for='answer-id-1335019' id='answer-label-1335019' class=' answer'><span>CHAP<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-21' style=';'><div id='questionWrap-21'  class='   watupro-question-id-341293'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>21. <\/span>You use iSCSI to present a LUN to a newly installed Windows 2016 Server. You have created the volume and LUN on the NetApp cluster. When you perform a hardware rescan on the Windows host, you cannot see the newly presented storage. <br \/>\r<br>What are three reasons for this problem? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_21' value='341293' \/><input type='hidden' id='answerType341293' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341293[]' id='answer-id-1335020' class='answer   answerof-341293 ' value='1335020'   \/><label for='answer-id-1335020' id='answer-label-1335020' class=' answer'><span>The protocol has not been enabled on the NetApp cluster.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341293[]' id='answer-id-1335021' class='answer   answerof-341293 ' value='1335021'   \/><label for='answer-id-1335021' id='answer-label-1335021' class=' answer'><span>You need to add the IQN of the Windows host to the newly created LU<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341293[]' id='answer-id-1335022' class='answer   answerof-341293 ' value='1335022'   \/><label for='answer-id-1335022' id='answer-label-1335022' class=' answer'><span>The IQN of the Windows host is not included in the igroup for the new LU<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341293[]' id='answer-id-1335023' class='answer   answerof-341293 ' value='1335023'   \/><label for='answer-id-1335023' id='answer-label-1335023' class=' answer'><span>The wrong igroup has been associated with the new LU<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341293[]' id='answer-id-1335024' class='answer   answerof-341293 ' value='1335024'   \/><label for='answer-id-1335024' id='answer-label-1335024' class=' answer'><span>The volume has not been enabled for iSCSI access.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-22' style=';'><div id='questionWrap-22'  class='   watupro-question-id-341294'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>22. <\/span>As a system administrator, you perform a routine check of available storage space on your FAS2750. You notice that the vol_1 volume is approaching 100% capacity. The volume is configured with the space guarantee set to volume and the LUN reservation is disabled. You want to free up space in the volume without increasing its size. <br \/>\r<br>Which action would accomplish this task?<\/div><input type='hidden' name='question_id[]' id='qID_22' value='341294' \/><input type='hidden' id='answerType341294' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341294[]' id='answer-id-1335025' class='answer   answerof-341294 ' value='1335025'   \/><label for='answer-id-1335025' id='answer-label-1335025' class=' answer'><span>Increase the size of the LU<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341294[]' id='answer-id-1335026' class='answer   answerof-341294 ' value='1335026'   \/><label for='answer-id-1335026' id='answer-label-1335026' class=' answer'><span>Increase the Snapshot Reserve.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341294[]' id='answer-id-1335027' class='answer   answerof-341294 ' value='1335027'   \/><label for='answer-id-1335027' id='answer-label-1335027' class=' answer'><span>Increase the aggregate size.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341294[]' id='answer-id-1335028' class='answer   answerof-341294 ' value='1335028'   \/><label for='answer-id-1335028' id='answer-label-1335028' class=' answer'><span>Use deduplication.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-23' style=';'><div id='questionWrap-23'  class='   watupro-question-id-341295'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>23. <\/span>An administrator reviews the Upgrade Advisor before performing an upgrade of their ONTAP cluster. <br \/>\r<br>What information is detailed in the report? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_23' value='341295' \/><input type='hidden' id='answerType341295' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341295[]' id='answer-id-1335029' class='answer   answerof-341295 ' value='1335029'   \/><label for='answer-id-1335029' id='answer-label-1335029' class=' answer'><span>pre-upgrade checks<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341295[]' id='answer-id-1335030' class='answer   answerof-341295 ' value='1335030'   \/><label for='answer-id-1335030' id='answer-label-1335030' class=' answer'><span>performance metrics<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341295[]' id='answer-id-1335031' class='answer   answerof-341295 ' value='1335031'   \/><label for='answer-id-1335031' id='answer-label-1335031' class=' answer'><span>risk exposures<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341295[]' id='answer-id-1335032' class='answer   answerof-341295 ' value='1335032'   \/><label for='answer-id-1335032' id='answer-label-1335032' class=' answer'><span>cluster interconnect checks<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-24' style=';'><div id='questionWrap-24'  class='   watupro-question-id-341296'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>24. <\/span>You want to create an additional SVM from the System Manager GUI to serve data only using block-based protocols. You know the SVM name, the aggregate containing the root volume, and the required protocols. <br \/>\r<br>What other information is required to successfully create this SVM?<\/div><input type='hidden' name='question_id[]' id='qID_24' value='341296' \/><input type='hidden' id='answerType341296' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341296[]' id='answer-id-1335033' class='answer   answerof-341296 ' value='1335033'   \/><label for='answer-id-1335033' id='answer-label-1335033' class=' answer'><span>name servers<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341296[]' id='answer-id-1335034' class='answer   answerof-341296 ' value='1335034'   \/><label for='answer-id-1335034' id='answer-label-1335034' class=' answer'><span>SVM Management LIF network details<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341296[]' id='answer-id-1335035' class='answer   answerof-341296 ' value='1335035'   \/><label for='answer-id-1335035' id='answer-label-1335035' class=' answer'><span>search domains<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341296[]' id='answer-id-1335036' class='answer   answerof-341296 ' value='1335036'   \/><label for='answer-id-1335036' id='answer-label-1335036' class=' answer'><span>root volume security style<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-25' style=';'><div id='questionWrap-25'  class='   watupro-question-id-341297'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>25. <\/span>An administrator is configuring their Ethernet switches to support an AFF A300 cluster that will be providing iSCSI LUNs to servers. The switches are also used for other traffic from various hosts. <br \/>\r<br>In this scenario, which statement about the switch configuration is correct?<\/div><input type='hidden' name='question_id[]' id='qID_25' value='341297' \/><input type='hidden' id='answerType341297' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341297[]' id='answer-id-1335037' class='answer   answerof-341297 ' value='1335037'   \/><label for='answer-id-1335037' id='answer-label-1335037' class=' answer'><span>Use a larger MTU size at the SAN connection rather than the host connections to allow for greater SAN bandwidth.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341297[]' id='answer-id-1335038' class='answer   answerof-341297 ' value='1335038'   \/><label for='answer-id-1335038' id='answer-label-1335038' class=' answer'><span>Use network ports as access ports only.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341297[]' id='answer-id-1335039' class='answer   answerof-341297 ' value='1335039'   \/><label for='answer-id-1335039' id='answer-label-1335039' class=' answer'><span>Use multiple VLANs to segregate iSCSI traffic from other traffic types<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341297[]' id='answer-id-1335040' class='answer   answerof-341297 ' value='1335040'   \/><label for='answer-id-1335040' id='answer-label-1335040' class=' answer'><span>Use a single VLAN to consolidate all data traffic on the switches.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-26' style=';'><div id='questionWrap-26'  class='   watupro-question-id-341298'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>26. <\/span>You are implementing a new AFF A800 HA pair and are required to migrate NetApp E-Series E2624 data to the AFF A800 controllers. You do not have a host server that is available for the migration. <br \/>\r<br>In this scenario, which NetApp migration method is supported?<\/div><input type='hidden' name='question_id[]' id='qID_26' value='341298' \/><input type='hidden' id='answerType341298' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341298[]' id='answer-id-1335041' class='answer   answerof-341298 ' value='1335041'   \/><label for='answer-id-1335041' id='answer-label-1335041' class=' answer'><span>OnCommand Unified Manager (OCUM)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341298[]' id='answer-id-1335042' class='answer   answerof-341298 ' value='1335042'   \/><label for='answer-id-1335042' id='answer-label-1335042' class=' answer'><span>NetApp Data Availability Services (NDAS)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341298[]' id='answer-id-1335043' class='answer   answerof-341298 ' value='1335043'   \/><label for='answer-id-1335043' id='answer-label-1335043' class=' answer'><span>SnapMirror Synchronous (SM-S)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341298[]' id='answer-id-1335044' class='answer   answerof-341298 ' value='1335044'   \/><label for='answer-id-1335044' id='answer-label-1335044' class=' answer'><span>Foreign LUN Import (FLI)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-27' style=';'><div id='questionWrap-27'  class='   watupro-question-id-341299'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>27. <\/span>You have three Windows servers and one Linux server, each with dual-ported HBAs that are connected into a dual fabric. <br \/>\r<br>In this scenario, what is the minimum number of zones that you need to create within each fabric switch?<\/div><input type='hidden' name='question_id[]' id='qID_27' value='341299' \/><input type='hidden' id='answerType341299' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341299[]' id='answer-id-1335045' class='answer   answerof-341299 ' value='1335045'   \/><label for='answer-id-1335045' id='answer-label-1335045' class=' answer'><span>8<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341299[]' id='answer-id-1335046' class='answer   answerof-341299 ' value='1335046'   \/><label for='answer-id-1335046' id='answer-label-1335046' class=' answer'><span>1<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341299[]' id='answer-id-1335047' class='answer   answerof-341299 ' value='1335047'   \/><label for='answer-id-1335047' id='answer-label-1335047' class=' answer'><span>4<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341299[]' id='answer-id-1335048' class='answer   answerof-341299 ' value='1335048'   \/><label for='answer-id-1335048' id='answer-label-1335048' class=' answer'><span>2<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-28' style=';'><div id='questionWrap-28'  class='   watupro-question-id-341300'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>28. <\/span>An administrator has an ONTAP cluster with SVMs and LUNs as shown in the exhibit. Hosts attempting to connect to LUNs mapped from SVM \u201cC\u201d are unable to see their LUNs. The hosts are not configured to connect to any other SVM. <br \/>\r<br><br><img decoding=\"async\" width=649 height=422 id=\"\u56fe\u7247 51\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image010-21.jpg\"><br><br \/>\r<br>Which action should be performed to restore multi-path connectivity to the LUNs in this scenario?<\/div><input type='hidden' name='question_id[]' id='qID_28' value='341300' \/><input type='hidden' id='answerType341300' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341300[]' id='answer-id-1335049' class='answer   answerof-341300 ' value='1335049'   \/><label for='answer-id-1335049' id='answer-label-1335049' class=' answer'><span>Create LIFs on SVM \u201cC\u201d for host connectivity.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341300[]' id='answer-id-1335050' class='answer   answerof-341300 ' value='1335050'   \/><label for='answer-id-1335050' id='answer-label-1335050' class=' answer'><span>Move the LUN to a different volume within SVM \u201cC\u201d.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341300[]' id='answer-id-1335051' class='answer   answerof-341300 ' value='1335051'   \/><label for='answer-id-1335051' id='answer-label-1335051' class=' answer'><span>Move the LUN to SVM \u201cE\u201d to restore connectivity.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341300[]' id='answer-id-1335052' class='answer   answerof-341300 ' value='1335052'   \/><label for='answer-id-1335052' id='answer-label-1335052' class=' answer'><span>Move the LUN to SVM \u201cA\u201d to restore connectivity.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-29' style=';'><div id='questionWrap-29'  class='   watupro-question-id-341301'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>29. <\/span>Referring to the exhibit, which two LIFs would be optimized paths to LUN \/vol\/OraDev_Vol\/OraDev? (Choose two.) <br \/>\r<br><br><img decoding=\"async\" width=649 height=369 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image011-20.jpg\"><br><\/div><input type='hidden' name='question_id[]' id='qID_29' value='341301' \/><input type='hidden' id='answerType341301' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341301[]' id='answer-id-1335053' class='answer   answerof-341301 ' value='1335053'   \/><label for='answer-id-1335053' id='answer-label-1335053' class=' answer'><span>aff_node-01_0g_A<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341301[]' id='answer-id-1335054' class='answer   answerof-341301 ' value='1335054'   \/><label for='answer-id-1335054' id='answer-label-1335054' class=' answer'><span>aff_node-02_0e_A<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341301[]' id='answer-id-1335055' class='answer   answerof-341301 ' value='1335055'   \/><label for='answer-id-1335055' id='answer-label-1335055' class=' answer'><span>aff_node-02_0g_A<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341301[]' id='answer-id-1335056' class='answer   answerof-341301 ' value='1335056'   \/><label for='answer-id-1335056' id='answer-label-1335056' class=' answer'><span>aff_node-01_0e_A<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-30' style=';'><div id='questionWrap-30'  class='   watupro-question-id-341302'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>30. <\/span>Automatic host-side space management with SCSI T10 thin-provisioned LUNs is achieved by which feature of ONTAP?<\/div><input type='hidden' name='question_id[]' id='qID_30' value='341302' \/><input type='hidden' id='answerType341302' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341302[]' id='answer-id-1335057' class='answer   answerof-341302 ' value='1335057'   \/><label for='answer-id-1335057' id='answer-label-1335057' class=' answer'><span>fractional reserve<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341302[]' id='answer-id-1335058' class='answer   answerof-341302 ' value='1335058'   \/><label for='answer-id-1335058' id='answer-label-1335058' class=' answer'><span>space allocation<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341302[]' id='answer-id-1335059' class='answer   answerof-341302 ' value='1335059'   \/><label for='answer-id-1335059' id='answer-label-1335059' class=' answer'><span>space reservation<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341302[]' id='answer-id-1335060' class='answer   answerof-341302 ' value='1335060'   \/><label for='answer-id-1335060' id='answer-label-1335060' class=' answer'><span>volume auto-grow<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-31' style=';'><div id='questionWrap-31'  class='   watupro-question-id-341303'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>31. <\/span>You are planning to expand a SAN-only ONTAP 9.5 cluster that consists of eight AFF A700 nodes. <br \/>\r<br>In this scenario, what is the maximum number of additional AFF A700 nodes that would be added?<\/div><input type='hidden' name='question_id[]' id='qID_31' value='341303' \/><input type='hidden' id='answerType341303' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341303[]' id='answer-id-1335061' class='answer   answerof-341303 ' value='1335061'   \/><label for='answer-id-1335061' id='answer-label-1335061' class=' answer'><span>2<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341303[]' id='answer-id-1335062' class='answer   answerof-341303 ' value='1335062'   \/><label for='answer-id-1335062' id='answer-label-1335062' class=' answer'><span>4<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341303[]' id='answer-id-1335063' class='answer   answerof-341303 ' value='1335063'   \/><label for='answer-id-1335063' id='answer-label-1335063' class=' answer'><span>8<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341303[]' id='answer-id-1335064' class='answer   answerof-341303 ' value='1335064'   \/><label for='answer-id-1335064' id='answer-label-1335064' class=' answer'><span>0<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-32' style=';'><div id='questionWrap-32'  class='   watupro-question-id-341304'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>32. <\/span>You have a 4 node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. <br \/>\r<br>With inline data compaction, you estimate that you can save 6% of storage space. AFF A300 LUNs that use under 5000 IOPS are moved to a FAS8200 using the lun move command. <br \/>\r<br>In this scenario, what happens to the data after the LUN is moved? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_32' value='341304' \/><input type='hidden' id='answerType341304' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341304[]' id='answer-id-1335065' class='answer   answerof-341304 ' value='1335065'   \/><label for='answer-id-1335065' id='answer-label-1335065' class=' answer'><span>The new written data is not compacted.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341304[]' id='answer-id-1335066' class='answer   answerof-341304 ' value='1335066'   \/><label for='answer-id-1335066' id='answer-label-1335066' class=' answer'><span>The new written data is compacted.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341304[]' id='answer-id-1335067' class='answer   answerof-341304 ' value='1335067'   \/><label for='answer-id-1335067' id='answer-label-1335067' class=' answer'><span>The existing data is compacted.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341304[]' id='answer-id-1335068' class='answer   answerof-341304 ' value='1335068'   \/><label for='answer-id-1335068' id='answer-label-1335068' class=' answer'><span>The existing data is not compacted.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-33' style=';'><div id='questionWrap-33'  class='   watupro-question-id-341305'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>33. <\/span>You configured a SAN host with a 4-node ONTAP 9.5 cluster that uses default settings. All paths are available from the host to the four nodes. You have a requirement to see only two paths to each LUN. One path is optimized and the other is non-optimized. <br \/>\r<br><br><img decoding=\"async\" width=580 height=433 id=\"\u56fe\u7247 44\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image012-18.jpg\"><br><br \/>\r<br>In this scenario, which NetApp SAN feature supports this requirement?<\/div><input type='hidden' name='question_id[]' id='qID_33' value='341305' \/><input type='hidden' id='answerType341305' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341305[]' id='answer-id-1335069' class='answer   answerof-341305 ' value='1335069'   \/><label for='answer-id-1335069' id='answer-label-1335069' class=' answer'><span>portsets<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341305[]' id='answer-id-1335070' class='answer   answerof-341305 ' value='1335070'   \/><label for='answer-id-1335070' id='answer-label-1335070' class=' answer'><span>SLM<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341305[]' id='answer-id-1335071' class='answer   answerof-341305 ' value='1335071'   \/><label for='answer-id-1335071' id='answer-label-1335071' class=' answer'><span>VLANs<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341305[]' id='answer-id-1335072' class='answer   answerof-341305 ' value='1335072'   \/><label for='answer-id-1335072' id='answer-label-1335072' class=' answer'><span>igroups<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-34' style=';'><div id='questionWrap-34'  class='   watupro-question-id-341306'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>34. <\/span>You are planning to implement a 32 Gb FC SAN on a 2-node AFF A700 ONTAP 9.5 cluster. You need to create 112 FC LIFs across the HA pair with a limit of 20 FC LIFs per physical HBA port. <br \/>\r<br>In this scenario, how many 2-port 32 Gb HBA cards do you need per storage controller?<\/div><input type='hidden' name='question_id[]' id='qID_34' value='341306' \/><input type='hidden' id='answerType341306' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341306[]' id='answer-id-1335073' class='answer   answerof-341306 ' value='1335073'   \/><label for='answer-id-1335073' id='answer-label-1335073' class=' answer'><span>2<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341306[]' id='answer-id-1335074' class='answer   answerof-341306 ' value='1335074'   \/><label for='answer-id-1335074' id='answer-label-1335074' class=' answer'><span>1<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341306[]' id='answer-id-1335075' class='answer   answerof-341306 ' value='1335075'   \/><label for='answer-id-1335075' id='answer-label-1335075' class=' answer'><span>4<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341306[]' id='answer-id-1335076' class='answer   answerof-341306 ' value='1335076'   \/><label for='answer-id-1335076' id='answer-label-1335076' class=' answer'><span>3<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-35' style=';'><div id='questionWrap-35'  class='   watupro-question-id-341307'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>35. <\/span>Referring to the exhibit, you have SAN LUNs on an AFF A700s and are asked to test an SSD shelf stack failure. <br \/>\r<br><br><img decoding=\"async\" width=651 height=365 id=\"\u56fe\u7247 20\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image013-17.jpg\"><br><br \/>\r<br>What is the maximum allowed number of failed paths per controller to shelf stack before a storage failover occurs?<\/div><input type='hidden' name='question_id[]' id='qID_35' value='341307' \/><input type='hidden' id='answerType341307' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341307[]' id='answer-id-1335077' class='answer   answerof-341307 ' value='1335077'   \/><label for='answer-id-1335077' id='answer-label-1335077' class=' answer'><span>1<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341307[]' id='answer-id-1335078' class='answer   answerof-341307 ' value='1335078'   \/><label for='answer-id-1335078' id='answer-label-1335078' class=' answer'><span>3<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341307[]' id='answer-id-1335079' class='answer   answerof-341307 ' value='1335079'   \/><label for='answer-id-1335079' id='answer-label-1335079' class=' answer'><span>2<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341307[]' id='answer-id-1335080' class='answer   answerof-341307 ' value='1335080'   \/><label for='answer-id-1335080' id='answer-label-1335080' class=' answer'><span>4<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-36' style=';'><div id='questionWrap-36'  class='   watupro-question-id-341308'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>36. <\/span>You have an SVM that serves LUNs to your hosts in an FC SAN environment. This SVM runs on a 4-node cluster and has two data LIFs on each node, according to best practices. You just created a LUN and mapped it to your initiators group. The LUN is owned by node01. <br \/>\r<br>In this scenario, what would be an appropriate test for LUN mobility?<\/div><input type='hidden' name='question_id[]' id='qID_36' value='341308' \/><input type='hidden' id='answerType341308' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341308[]' id='answer-id-1335081' class='answer   answerof-341308 ' value='1335081'   \/><label for='answer-id-1335081' id='answer-label-1335081' class=' answer'><span>Move the LUN to node02.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341308[]' id='answer-id-1335082' class='answer   answerof-341308 ' value='1335082'   \/><label for='answer-id-1335082' id='answer-label-1335082' class=' answer'><span>Mirror the LUN to another node in your cluster.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341308[]' id='answer-id-1335083' class='answer   answerof-341308 ' value='1335083'   \/><label for='answer-id-1335083' id='answer-label-1335083' class=' answer'><span>Physically disconnect the SAN ports, and verify if the SAN data LIFs automatically move to other hosts.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341308[]' id='answer-id-1335084' class='answer   answerof-341308 ' value='1335084'   \/><label for='answer-id-1335084' id='answer-label-1335084' class=' answer'><span>Copy the LUN to another node and create a new LUN map.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-37' style=';'><div id='questionWrap-37'  class='   watupro-question-id-341309'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>37. <\/span>While expanding a 200 GB LUN in an ONTAP 9.4 system, the following error is observed: <br \/>\r<br><br><img decoding=\"async\" width=619 height=39 id=\"\u56fe\u7247 28\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image014-17.jpg\" alt=\"https:\/\/www.nwexam.com\/files\/nwexam\/download\/NS0-509-VCE_18.png\"><br><br \/>\r<br>What is the cause of this error?<\/div><input type='hidden' name='question_id[]' id='qID_37' value='341309' \/><input type='hidden' id='answerType341309' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341309[]' id='answer-id-1335085' class='answer   answerof-341309 ' value='1335085'   \/><label for='answer-id-1335085' id='answer-label-1335085' class=' answer'><span>The volume auto-grow is disabled.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341309[]' id='answer-id-1335086' class='answer   answerof-341309 ' value='1335086'   \/><label for='answer-id-1335086' id='answer-label-1335086' class=' answer'><span>The LUN reached maximum capacity.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341309[]' id='answer-id-1335087' class='answer   answerof-341309 ' value='1335087'   \/><label for='answer-id-1335087' id='answer-label-1335087' class=' answer'><span>The LUN can be expanded up to 10 times its original size.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341309[]' id='answer-id-1335088' class='answer   answerof-341309 ' value='1335088'   \/><label for='answer-id-1335088' id='answer-label-1335088' class=' answer'><span>Space reservation is enabled.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-38' style=';'><div id='questionWrap-38'  class='   watupro-question-id-341310'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>38. <\/span>You have a LUN owned by Node 01 and mapped using the default Selective LUN Map (SLM) configuration. You want to enable your host to access this LUN and facilitate future maintenance. <br \/>\r<br><br><img decoding=\"async\" width=580 height=433 id=\"\u56fe\u7247 35\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image012-19.jpg\"><br><br \/>\r<br>Which best-practice zone configuration accomplishes this task ?<\/div><input type='hidden' name='question_id[]' id='qID_38' value='341310' \/><input type='hidden' id='answerType341310' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341310[]' id='answer-id-1335089' class='answer   answerof-341310 ' value='1335089'   \/><label for='answer-id-1335089' id='answer-label-1335089' class=' answer'><span>Zone 1: HBA 0, LIF_1, LIF_3, LIF_5 and LIF_7 \r\nZone 2: HBA 1, LIF_2, LIF_4, LIF_6 and LIF_8<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341310[]' id='answer-id-1335090' class='answer   answerof-341310 ' value='1335090'   \/><label for='answer-id-1335090' id='answer-label-1335090' class=' answer'><span>Zone 1: HBA 0, HBA 1, LIF_1, LIF_2, LIF_3, LIF_4, LIF_5, LIF_6, LIF_7, LIF_8<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341310[]' id='answer-id-1335091' class='answer   answerof-341310 ' value='1335091'   \/><label for='answer-id-1335091' id='answer-label-1335091' class=' answer'><span>Zone 1: HBA 0, LIF_1, LIF_3 \r\nZone 2: HBA 1, LIF_2, LIF_4<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341310[]' id='answer-id-1335092' class='answer   answerof-341310 ' value='1335092'   \/><label for='answer-id-1335092' id='answer-label-1335092' class=' answer'><span>Zone 1: HBA 0, HBA 1, LIF_1, LIF_2, L1F_3, LIF_4<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-39' style=';'><div id='questionWrap-39'  class='   watupro-question-id-341311'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>39. <\/span>Which path selection policy is used by Windows Servers using NetApp LUNs that are greater than 2 TB?<\/div><input type='hidden' name='question_id[]' id='qID_39' value='341311' \/><input type='hidden' id='answerType341311' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341311[]' id='answer-id-1335093' class='answer   answerof-341311 ' value='1335093'   \/><label for='answer-id-1335093' id='answer-label-1335093' class=' answer'><span>Least Queue Depth<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341311[]' id='answer-id-1335094' class='answer   answerof-341311 ' value='1335094'   \/><label for='answer-id-1335094' id='answer-label-1335094' class=' answer'><span>Round Robin<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341311[]' id='answer-id-1335095' class='answer   answerof-341311 ' value='1335095'   \/><label for='answer-id-1335095' id='answer-label-1335095' class=' answer'><span>Round Robin with Subset Policy<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341311[]' id='answer-id-1335096' class='answer   answerof-341311 ' value='1335096'   \/><label for='answer-id-1335096' id='answer-label-1335096' class=' answer'><span>Least Weighted Paths<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-40' style=';'><div id='questionWrap-40'  class='   watupro-question-id-341312'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>40. <\/span>Which two are supported in ONTAP 9.5? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_40' value='341312' \/><input type='hidden' id='answerType341312' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341312[]' id='answer-id-1335097' class='answer   answerof-341312 ' value='1335097'   \/><label for='answer-id-1335097' id='answer-label-1335097' class=' answer'><span>an NVMe LIF and an FC LIF in the same SVM<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341312[]' id='answer-id-1335098' class='answer   answerof-341312 ' value='1335098'   \/><label for='answer-id-1335098' id='answer-label-1335098' class=' answer'><span>an NVMe LIF associated with an FC Direct Connect port<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341312[]' id='answer-id-1335099' class='answer   answerof-341312 ' value='1335099'   \/><label for='answer-id-1335099' id='answer-label-1335099' class=' answer'><span>a NVMe LIF and an FC LIF associated with the same port<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341312[]' id='answer-id-1335100' class='answer   answerof-341312 ' value='1335100'   \/><label for='answer-id-1335100' id='answer-label-1335100' class=' answer'><span>multiple NVMe LIFs in the same SVM<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-41' style=';'><div id='questionWrap-41'  class='   watupro-question-id-341313'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>41. <\/span>An administrator who is using the Virtual Storage Console (VSC) creates a new FC datastore on an existing volume. While the datastore was provisioned, two hosts were in maintenance mode. When the maintenance was completed, the two hosts do not have access to the new datastore, but they have access to other datastores on the same volume. <br \/>\r<br>In this scenario, what caused this result?<\/div><input type='hidden' name='question_id[]' id='qID_41' value='341313' \/><input type='hidden' id='answerType341313' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341313[]' id='answer-id-1335101' class='answer   answerof-341313 ' value='1335101'   \/><label for='answer-id-1335101' id='answer-label-1335101' class=' answer'><span>The VSC cannot create datastores while hosts are in maintenance mode.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341313[]' id='answer-id-1335102' class='answer   answerof-341313 ' value='1335102'   \/><label for='answer-id-1335102' id='answer-label-1335102' class=' answer'><span>During host maintenance, the FC HBAs were replaced with different FC HBAs.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341313[]' id='answer-id-1335103' class='answer   answerof-341313 ' value='1335103'   \/><label for='answer-id-1335103' id='answer-label-1335103' class=' answer'><span>The VSC created a new igroup that contains only the hosts that were online during the datastore creation.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341313[]' id='answer-id-1335104' class='answer   answerof-341313 ' value='1335104'   \/><label for='answer-id-1335104' id='answer-label-1335104' class=' answer'><span>After creation using the VSC, the administrator needs to create a LUN mapping.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-42' style=';'><div id='questionWrap-42'  class='   watupro-question-id-341314'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>42. <\/span>An administrator is configuring a SAN-only cluster. The data room that houses four AFF A220 controllers is small and not able to house the DS224C shelves. The administrator proposes to rack the shelves in a separate room that is 40 meters away from the controllers. <br \/>\r<br>In this situation, how would you properly cable the controllers to the shelves?<\/div><input type='hidden' name='question_id[]' id='qID_42' value='341314' \/><input type='hidden' id='answerType341314' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341314[]' id='answer-id-1335105' class='answer   answerof-341314 ' value='1335105'   \/><label for='answer-id-1335105' id='answer-label-1335105' class=' answer'><span>Use multimode passive optical cables.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341314[]' id='answer-id-1335106' class='answer   answerof-341314 ' value='1335106'   \/><label for='answer-id-1335106' id='answer-label-1335106' class=' answer'><span>Use multimode active copper cables.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341314[]' id='answer-id-1335107' class='answer   answerof-341314 ' value='1335107'   \/><label for='answer-id-1335107' id='answer-label-1335107' class=' answer'><span>Use multimode active optical cables.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341314[]' id='answer-id-1335108' class='answer   answerof-341314 ' value='1335108'   \/><label for='answer-id-1335108' id='answer-label-1335108' class=' answer'><span>Use multimode passive copper cables.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-43' style=';'><div id='questionWrap-43'  class='   watupro-question-id-341315'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>43. <\/span>Which three components are required for NetApp iSCSI LUN access on Linux servers? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_43' value='341315' \/><input type='hidden' id='answerType341315' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341315[]' id='answer-id-1335109' class='answer   answerof-341315 ' value='1335109'   \/><label for='answer-id-1335109' id='answer-label-1335109' class=' answer'><span>device-mapper-multipath<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341315[]' id='answer-id-1335110' class='answer   answerof-341315 ' value='1335110'   \/><label for='answer-id-1335110' id='answer-label-1335110' class=' answer'><span>NetApp SnapDrive<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341315[]' id='answer-id-1335111' class='answer   answerof-341315 ' value='1335111'   \/><label for='answer-id-1335111' id='answer-label-1335111' class=' answer'><span>iscsi-target-utils<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341315[]' id='answer-id-1335112' class='answer   answerof-341315 ' value='1335112'   \/><label for='answer-id-1335112' id='answer-label-1335112' class=' answer'><span>iscsi-initiator-utils<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341315[]' id='answer-id-1335113' class='answer   answerof-341315 ' value='1335113'   \/><label for='answer-id-1335113' id='answer-label-1335113' class=' answer'><span>NetApp Host Utilities<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-44' style=';'><div id='questionWrap-44'  class='   watupro-question-id-341316'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>44. <\/span>An administrator has a new AFF A220 system with two DS224C disk shelves and wants to validate if the shelf cabling is correct. <br \/>\r<br>Which resource would be used to accomplish this task?<\/div><input type='hidden' name='question_id[]' id='qID_44' value='341316' \/><input type='hidden' id='answerType341316' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341316[]' id='answer-id-1335114' class='answer   answerof-341316 ' value='1335114'   \/><label for='answer-id-1335114' id='answer-label-1335114' class=' answer'><span>Config Advisor<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341316[]' id='answer-id-1335115' class='answer   answerof-341316 ' value='1335115'   \/><label for='answer-id-1335115' id='answer-label-1335115' class=' answer'><span>OnCommand Unified Manager (OCUM)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341316[]' id='answer-id-1335116' class='answer   answerof-341316 ' value='1335116'   \/><label for='answer-id-1335116' id='answer-label-1335116' class=' answer'><span>OneCollect<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341316[]' id='answer-id-1335117' class='answer   answerof-341316 ' value='1335117'   \/><label for='answer-id-1335117' id='answer-label-1335117' class=' answer'><span>Interoperability Matrix Tool (IMT)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-45' style=';'><div id='questionWrap-45'  class='   watupro-question-id-341317'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>45. <\/span>You currently have a FAS8200 with ONTAP 9.5. You want to expand the front end FC I\/O capabilities. However, you are unsure which target adapters are supported. <br \/>\r<br>What would you use to confirm which adapters are supported with your current configuration?<\/div><input type='hidden' name='question_id[]' id='qID_45' value='341317' \/><input type='hidden' id='answerType341317' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341317[]' id='answer-id-1335118' class='answer   answerof-341317 ' value='1335118'   \/><label for='answer-id-1335118' id='answer-label-1335118' class=' answer'><span>Hardware Universe (HWU)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341317[]' id='answer-id-1335119' class='answer   answerof-341317 ' value='1335119'   \/><label for='answer-id-1335119' id='answer-label-1335119' class=' answer'><span>Upgrade Advisor<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341317[]' id='answer-id-1335120' class='answer   answerof-341317 ' value='1335120'   \/><label for='answer-id-1335120' id='answer-label-1335120' class=' answer'><span>OneCollect<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341317[]' id='answer-id-1335121' class='answer   answerof-341317 ' value='1335121'   \/><label for='answer-id-1335121' id='answer-label-1335121' class=' answer'><span>Interoperability Matrix Tool (IMT)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-46' style=';'><div id='questionWrap-46'  class='   watupro-question-id-341318'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>46. <\/span>Which two storage efficiencies have been enabled on the NVMe namespace that is shown in the exhibit? (Choose two.) <br \/>\r<br><br><img decoding=\"async\" width=648 height=224 id=\"\u56fe\u7247 53\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image015-16.jpg\"><br><\/div><input type='hidden' name='question_id[]' id='qID_46' value='341318' \/><input type='hidden' id='answerType341318' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341318[]' id='answer-id-1335122' class='answer   answerof-341318 ' value='1335122'   \/><label for='answer-id-1335122' id='answer-label-1335122' class=' answer'><span>deduplication<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341318[]' id='answer-id-1335123' class='answer   answerof-341318 ' value='1335123'   \/><label for='answer-id-1335123' id='answer-label-1335123' class=' answer'><span>compaction<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341318[]' id='answer-id-1335124' class='answer   answerof-341318 ' value='1335124'   \/><label for='answer-id-1335124' id='answer-label-1335124' class=' answer'><span>compression<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341318[]' id='answer-id-1335125' class='answer   answerof-341318 ' value='1335125'   \/><label for='answer-id-1335125' id='answer-label-1335125' class=' answer'><span>thin provisioning<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-47' style=';'><div id='questionWrap-47'  class='   watupro-question-id-341319'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>47. <\/span>You have a performance critical database application that is running on a FAS9000 controller that uses FC. As shown in the exhibit, volume efficiency is enabled. <br \/>\r<br><br><img decoding=\"async\" width=651 height=248 id=\"\u56fe\u7247 30\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image016-15.jpg\"><br><br \/>\r<br>If you follow the performance recommendation, what are two results to the data in the volume? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_47' value='341319' \/><input type='hidden' id='answerType341319' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341319[]' id='answer-id-1335126' class='answer   answerof-341319 ' value='1335126'   \/><label for='answer-id-1335126' id='answer-label-1335126' class=' answer'><span>The new written data is compressed.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341319[]' id='answer-id-1335127' class='answer   answerof-341319 ' value='1335127'   \/><label for='answer-id-1335127' id='answer-label-1335127' class=' answer'><span>The new written data is uncompressed.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341319[]' id='answer-id-1335128' class='answer   answerof-341319 ' value='1335128'   \/><label for='answer-id-1335128' id='answer-label-1335128' class=' answer'><span>The existing data is uncompressed.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341319[]' id='answer-id-1335129' class='answer   answerof-341319 ' value='1335129'   \/><label for='answer-id-1335129' id='answer-label-1335129' class=' answer'><span>The existing data is compressed.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-48' style=';'><div id='questionWrap-48'  class='   watupro-question-id-341320'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>48. <\/span>You are configuring both NVMe and FC on the same AFF A800 2-node ONTAP 9.5 cluster. You are configuring both protocols on the same Cisco FC network switches. <br \/>\r<br>In this scenario, which configuration on the cluster is supported?<\/div><input type='hidden' name='question_id[]' id='qID_48' value='341320' \/><input type='hidden' id='answerType341320' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341320[]' id='answer-id-1335130' class='answer   answerof-341320 ' value='1335130'   \/><label for='answer-id-1335130' id='answer-label-1335130' class=' answer'><span>a volume with both LUNs and namespaces<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341320[]' id='answer-id-1335131' class='answer   answerof-341320 ' value='1335131'   \/><label for='answer-id-1335131' id='answer-label-1335131' class=' answer'><span>an SVM with both nvme and fcp allowed protocols<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341320[]' id='answer-id-1335132' class='answer   answerof-341320 ' value='1335132'   \/><label for='answer-id-1335132' id='answer-label-1335132' class=' answer'><span>an AFF A800 node HBA with both NVMe\/FC and FC on the same port<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341320[]' id='answer-id-1335133' class='answer   answerof-341320 ' value='1335133'   \/><label for='answer-id-1335133' id='answer-label-1335133' class=' answer'><span>a LIF with both fc-nvme and fcp data protocols<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-49' style=';'><div id='questionWrap-49'  class='   watupro-question-id-341321'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>49. <\/span>You connected your FAS8200 to a Brocade SAN switch. <br \/>\r<br><br><img decoding=\"async\" width=651 height=243 id=\"\u56fe\u7247 43\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image017-15.jpg\"><br><br \/>\r<br>As shown in the exhibit, port 0e is not available. <br \/>\r<br>In this scenario, which statement is correct?<\/div><input type='hidden' name='question_id[]' id='qID_49' value='341321' \/><input type='hidden' id='answerType341321' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341321[]' id='answer-id-1335134' class='answer   answerof-341321 ' value='1335134'   \/><label for='answer-id-1335134' id='answer-label-1335134' class=' answer'><span>The incorrect SFP+ module is installed.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341321[]' id='answer-id-1335135' class='answer   answerof-341321 ' value='1335135'   \/><label for='answer-id-1335135' id='answer-label-1335135' class=' answer'><span>The switch zoning is using the FC nodename.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341321[]' id='answer-id-1335136' class='answer   answerof-341321 ' value='1335136'   \/><label for='answer-id-1335136' id='answer-label-1335136' class=' answer'><span>The incorrect firmware revision is installed.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341321[]' id='answer-id-1335137' class='answer   answerof-341321 ' value='1335137'   \/><label for='answer-id-1335137' id='answer-label-1335137' class=' answer'><span>The switch port is configured for mode E_Port.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-50' style=';'><div id='questionWrap-50'  class='   watupro-question-id-341322'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>50. <\/span>An administrator wants to design an NVMe solution to connect Linux hosts to an ONTAP cluster. The proposed solution uses two Cisco MDS 9396T switches for each fabric in a top-of-rack design. <br \/>\r<br>In this scenario, which statement is true?<\/div><input type='hidden' name='question_id[]' id='qID_50' value='341322' \/><input type='hidden' id='answerType341322' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341322[]' id='answer-id-1335138' class='answer   answerof-341322 ' value='1335138'   \/><label for='answer-id-1335138' id='answer-label-1335138' class=' answer'><span>Asymmetric Namespace Access requires ONTAP 9.4 and higher.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341322[]' id='answer-id-1335139' class='answer   answerof-341322 ' value='1335139'   \/><label for='answer-id-1335139' id='answer-label-1335139' class=' answer'><span>NVMe solutions require heterogeneous multiple switch fabrics.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341322[]' id='answer-id-1335140' class='answer   answerof-341322 ' value='1335140'   \/><label for='answer-id-1335140' id='answer-label-1335140' class=' answer'><span>N_Port ID virtualization (NPIV) must be enabled on all switches.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341322[]' id='answer-id-1335141' class='answer   answerof-341322 ' value='1335141'   \/><label for='answer-id-1335141' id='answer-label-1335141' class=' answer'><span>A middle-of-rack design is required.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-51' style=';'><div id='questionWrap-51'  class='   watupro-question-id-341323'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>51. <\/span>On your ONTAP 9.5 cluster, you need to set up the onboard key manager with hardware-based security and volume encryption. <br \/>\r<br>Which two licenses are required in this situation? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_51' value='341323' \/><input type='hidden' id='answerType341323' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341323[]' id='answer-id-1335142' class='answer   answerof-341323 ' value='1335142'   \/><label for='answer-id-1335142' id='answer-label-1335142' class=' answer'><span>FDE<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341323[]' id='answer-id-1335143' class='answer   answerof-341323 ' value='1335143'   \/><label for='answer-id-1335143' id='answer-label-1335143' class=' answer'><span>TPM<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341323[]' id='answer-id-1335144' class='answer   answerof-341323 ' value='1335144'   \/><label for='answer-id-1335144' id='answer-label-1335144' class=' answer'><span>VE<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341323[]' id='answer-id-1335145' class='answer   answerof-341323 ' value='1335145'   \/><label for='answer-id-1335145' id='answer-label-1335145' class=' answer'><span>RSA<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-52' style=';'><div id='questionWrap-52'  class='   watupro-question-id-341324'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>52. <\/span>A customer is planning to connect a Linux server to a FAS8200 using Brocade FC switches. During the initial configuration, the SVM does not log in to the fabric. <br \/>\r<br>Which two statements are correct in this scenario? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_52' value='341324' \/><input type='hidden' id='answerType341324' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341324[]' id='answer-id-1335146' class='answer   answerof-341324 ' value='1335146'   \/><label for='answer-id-1335146' id='answer-label-1335146' class=' answer'><span>NPIV has not been enabled on the switches.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341324[]' id='answer-id-1335147' class='answer   answerof-341324 ' value='1335147'   \/><label for='answer-id-1335147' id='answer-label-1335147' class=' answer'><span>The switch port topology is set incorrectly to the E_Port.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341324[]' id='answer-id-1335148' class='answer   answerof-341324 ' value='1335148'   \/><label for='answer-id-1335148' id='answer-label-1335148' class=' answer'><span>ALUA has not been set up on the FAS8200.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341324[]' id='answer-id-1335149' class='answer   answerof-341324 ' value='1335149'   \/><label for='answer-id-1335149' id='answer-label-1335149' class=' answer'><span>Zoning is incorrectly configured between the Linux server and the ONTAP cluster.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-53' style=';'><div id='questionWrap-53'  class='   watupro-question-id-341325'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>53. <\/span>You need to configure iSCSI on your existing ONTAP cluster in a new SVM. The iSCSI LUNs will be served over a new Layer 2 network using the same physical ports that also use the CIFS protocol on a different SVM. <br \/>\r<br>Which two actions should you perform to accomplish this task? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_53' value='341325' \/><input type='hidden' id='answerType341325' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341325[]' id='answer-id-1335150' class='answer   answerof-341325 ' value='1335150'   \/><label for='answer-id-1335150' id='answer-label-1335150' class=' answer'><span>Create a new portset.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341325[]' id='answer-id-1335151' class='answer   answerof-341325 ' value='1335151'   \/><label for='answer-id-1335151' id='answer-label-1335151' class=' answer'><span>Create a new VLA<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341325[]' id='answer-id-1335152' class='answer   answerof-341325 ' value='1335152'   \/><label for='answer-id-1335152' id='answer-label-1335152' class=' answer'><span>Create a new broadcast domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341325[]' id='answer-id-1335153' class='answer   answerof-341325 ' value='1335153'   \/><label for='answer-id-1335153' id='answer-label-1335153' class=' answer'><span>Create a new AD object.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-54' style=';'><div id='questionWrap-54'  class='   watupro-question-id-341326'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>54. <\/span>Referring to the exhibit, what is the problem with switch port 0? <br \/>\r<br><br><img decoding=\"async\" width=651 height=181 id=\"\u56fe\u7247 24\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image018-14.jpg\"><br><\/div><input type='hidden' name='question_id[]' id='qID_54' value='341326' \/><input type='hidden' id='answerType341326' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341326[]' id='answer-id-1335154' class='answer   answerof-341326 ' value='1335154'   \/><label for='answer-id-1335154' id='answer-label-1335154' class=' answer'><span>The transmit and receive links were switched.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341326[]' id='answer-id-1335155' class='answer   answerof-341326 ' value='1335155'   \/><label for='answer-id-1335155' id='answer-label-1335155' class=' answer'><span>The SFP+ is faulty.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341326[]' id='answer-id-1335156' class='answer   answerof-341326 ' value='1335156'   \/><label for='answer-id-1335156' id='answer-label-1335156' class=' answer'><span>The receive power is lower.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341326[]' id='answer-id-1335157' class='answer   answerof-341326 ' value='1335157'   \/><label for='answer-id-1335157' id='answer-label-1335157' class=' answer'><span>The link is not connected.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-55' style=';'><div id='questionWrap-55'  class='   watupro-question-id-341327'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>55. <\/span>An administrator has expanded a 2-node ONTAP cluster to a 4-node ONTAP cluster. The cluster is using FC LUNs with all of the default settings. You must rebalance the LUNs to the new nodes. <br \/>\r<br>Which configuration must be made to achieve this requirement?<\/div><input type='hidden' name='question_id[]' id='qID_55' value='341327' \/><input type='hidden' id='answerType341327' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341327[]' id='answer-id-1335158' class='answer   answerof-341327 ' value='1335158'   \/><label for='answer-id-1335158' id='answer-label-1335158' class=' answer'><span>The new nodes must be added to the reporting nodes list.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341327[]' id='answer-id-1335159' class='answer   answerof-341327 ' value='1335159'   \/><label for='answer-id-1335159' id='answer-label-1335159' class=' answer'><span>All nodes must be removed from the reporting nodes list.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341327[]' id='answer-id-1335160' class='answer   answerof-341327 ' value='1335160'   \/><label for='answer-id-1335160' id='answer-label-1335160' class=' answer'><span>The original nodes must be added to the reporting nodes list.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341327[]' id='answer-id-1335161' class='answer   answerof-341327 ' value='1335161'   \/><label for='answer-id-1335161' id='answer-label-1335161' class=' answer'><span>The original nodes must be removed from the reporting nodes list.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-56' style=';'><div id='questionWrap-56'  class='   watupro-question-id-341328'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>56. <\/span>Referring to the exhibit, which container gains space savings from deduplication, compression and compaction? <br \/>\r<br><br><img decoding=\"async\" width=476 height=149 id=\"\u56fe\u7247 45\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image019-14.jpg\"><br><\/div><input type='hidden' name='question_id[]' id='qID_56' value='341328' \/><input type='hidden' id='answerType341328' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341328[]' id='answer-id-1335162' class='answer   answerof-341328 ' value='1335162'   \/><label for='answer-id-1335162' id='answer-label-1335162' class=' answer'><span>the aggregate<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341328[]' id='answer-id-1335163' class='answer   answerof-341328 ' value='1335163'   \/><label for='answer-id-1335163' id='answer-label-1335163' class=' answer'><span>the qtree<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341328[]' id='answer-id-1335164' class='answer   answerof-341328 ' value='1335164'   \/><label for='answer-id-1335164' id='answer-label-1335164' class=' answer'><span>the volume<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341328[]' id='answer-id-1335165' class='answer   answerof-341328 ' value='1335165'   \/><label for='answer-id-1335165' id='answer-label-1335165' class=' answer'><span>the LUN<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-57' style=';'><div id='questionWrap-57'  class='   watupro-question-id-341329'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>57. <\/span>Referring to the exhibit, which three steps are required to accomplish this task? (Choose three.) <br \/>\r<br><br><img decoding=\"async\" width=649 height=282 id=\"\u56fe\u7247 19\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image020-15.jpg\"><br><\/div><input type='hidden' name='question_id[]' id='qID_57' value='341329' \/><input type='hidden' id='answerType341329' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341329[]' id='answer-id-1335166' class='answer   answerof-341329 ' value='1335166'   \/><label for='answer-id-1335166' id='answer-label-1335166' class=' answer'><span>Issue the ucadmin modify -node AFF_1 -adapter 0e -mode FC -type target command.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341329[]' id='answer-id-1335167' class='answer   answerof-341329 ' value='1335167'   \/><label for='answer-id-1335167' id='answer-label-1335167' class=' answer'><span>Issue the ucadmin modify -node AFF_1 -adapter 0e -mode FC -type initiator command.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341329[]' id='answer-id-1335168' class='answer   answerof-341329 ' value='1335168'   \/><label for='answer-id-1335168' id='answer-label-1335168' class=' answer'><span>Restart the FC service.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341329[]' id='answer-id-1335169' class='answer   answerof-341329 ' value='1335169'   \/><label for='answer-id-1335169' id='answer-label-1335169' class=' answer'><span>Take ports 0e and of offline.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341329[]' id='answer-id-1335170' class='answer   answerof-341329 ' value='1335170'   \/><label for='answer-id-1335170' id='answer-label-1335170' class=' answer'><span>Reboot the node.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-58' style=';'><div id='questionWrap-58'  class='   watupro-question-id-341330'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>58. <\/span>You want to connect a NetApp AFF A700 to a 32 Gb FC switch. The ports need to connect at 32 Gb speed. <br \/>\r<br>In this scenario, which statement is correct?<\/div><input type='hidden' name='question_id[]' id='qID_58' value='341330' \/><input type='hidden' id='answerType341330' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341330[]' id='answer-id-1335171' class='answer   answerof-341330 ' value='1335171'   \/><label for='answer-id-1335171' id='answer-label-1335171' class=' answer'><span>The AFF A700 includes FC ports natively on the controller.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341330[]' id='answer-id-1335172' class='answer   answerof-341330 ' value='1335172'   \/><label for='answer-id-1335172' id='answer-label-1335172' class=' answer'><span>The AFF A700 includes an additional FC I\/O module that is already populated in each controller.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341330[]' id='answer-id-1335173' class='answer   answerof-341330 ' value='1335173'   \/><label for='answer-id-1335173' id='answer-label-1335173' class=' answer'><span>You need to purchase a two-port or four-port unified I\/O module that enables FC and Ethernet connectivity.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341330[]' id='answer-id-1335174' class='answer   answerof-341330 ' value='1335174'   \/><label for='answer-id-1335174' id='answer-label-1335174' class=' answer'><span>You need to purchase a two-port or four-port FC I\/O module.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-59' style=';'><div id='questionWrap-59'  class='   watupro-question-id-341331'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>59. <\/span>You are troubleshooting high CPU use on a FAS8200 with all SAS HDDs. You have SAN hosts with LUNs in a volume named vol1. You want to reduce CPU use and maintain storage efficiencies. <br \/>\r<br><br><img decoding=\"async\" width=651 height=306 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image021-14.jpg\"><br><br \/>\r<br>Referring to the exhibit which three actions will accomplish this task? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_59' value='341331' \/><input type='hidden' id='answerType341331' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341331[]' id='answer-id-1335175' class='answer   answerof-341331 ' value='1335175'   \/><label for='answer-id-1335175' id='answer-label-1335175' class=' answer'><span>Disable compression.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341331[]' id='answer-id-1335176' class='answer   answerof-341331 ' value='1335176'   \/><label for='answer-id-1335176' id='answer-label-1335176' class=' answer'><span>Enable cross-volume deduplication.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341331[]' id='answer-id-1335177' class='answer   answerof-341331 ' value='1335177'   \/><label for='answer-id-1335177' id='answer-label-1335177' class=' answer'><span>Disable inline deduplication.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341331[]' id='answer-id-1335178' class='answer   answerof-341331 ' value='1335178'   \/><label for='answer-id-1335178' id='answer-label-1335178' class=' answer'><span>Enable post process deduplication.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341331[]' id='answer-id-1335179' class='answer   answerof-341331 ' value='1335179'   \/><label for='answer-id-1335179' id='answer-label-1335179' class=' answer'><span>Enable data compaction.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-60' style=';'><div id='questionWrap-60'  class='   watupro-question-id-341332'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>60. <\/span>You create a 20 GB LUN in a newly created 100 GB FlexVol volume. You then write 5 GB of data to the LUN. You have space reservation disabled on the LUN. <br \/>\r<br>In this scenario, how much space do you have left on the volume?<\/div><input type='hidden' name='question_id[]' id='qID_60' value='341332' \/><input type='hidden' id='answerType341332' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341332[]' id='answer-id-1335180' class='answer   answerof-341332 ' value='1335180'   \/><label for='answer-id-1335180' id='answer-label-1335180' class=' answer'><span>95 GB<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341332[]' id='answer-id-1335181' class='answer   answerof-341332 ' value='1335181'   \/><label for='answer-id-1335181' id='answer-label-1335181' class=' answer'><span>80 GB<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341332[]' id='answer-id-1335182' class='answer   answerof-341332 ' value='1335182'   \/><label for='answer-id-1335182' id='answer-label-1335182' class=' answer'><span>75 GB<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341332[]' id='answer-id-1335183' class='answer   answerof-341332 ' value='1335183'   \/><label for='answer-id-1335183' id='answer-label-1335183' class=' answer'><span>85 GB<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-61' style=';'><div id='questionWrap-61'  class='   watupro-question-id-341333'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>61. <\/span>Changes to your organization requires access to an SVM be given to a group of individuals. Your company uses Active Directory as a method of access control. You decide to use the security login create - vserver engCluster -user-or-group-name CORPAdmins -application ssh -authmethod domain -role vsadmin command. <br \/>\r<br>In this scenario, which access rights will this command grant?<\/div><input type='hidden' name='question_id[]' id='qID_61' value='341333' \/><input type='hidden' id='answerType341333' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341333[]' id='answer-id-1335184' class='answer   answerof-341333 ' value='1335184'   \/><label for='answer-id-1335184' id='answer-label-1335184' class=' answer'><span>read only rights to the SVM engCluster for Active Directory group CORP<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341333[]' id='answer-id-1335185' class='answer   answerof-341333 ' value='1335185'   \/><label for='answer-id-1335185' id='answer-label-1335185' class=' answer'><span>vsadmin rights to the SVM engCluster for Active Directory group CORPAdmins<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341333[]' id='answer-id-1335186' class='answer   answerof-341333 ' value='1335186'   \/><label for='answer-id-1335186' id='answer-label-1335186' class=' answer'><span>vsadmin rights to the SVM CORP for Active Directory group CORPAdmins<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341333[]' id='answer-id-1335187' class='answer   answerof-341333 ' value='1335187'   \/><label for='answer-id-1335187' id='answer-label-1335187' class=' answer'><span>vsadmin rights to the SVM engCluster for Active Directory group CORP<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-62' style=';'><div id='questionWrap-62'  class='   watupro-question-id-341334'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>62. <\/span>A customer has multiple host applications that require FC block storage. You need to gather and validate the customer's requirements for a supported NetApp solution. <br \/>\r<br>Which two tools would be used to accomplish this task? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_62' value='341334' \/><input type='hidden' id='answerType341334' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341334[]' id='answer-id-1335188' class='answer   answerof-341334 ' value='1335188'   \/><label for='answer-id-1335188' id='answer-label-1335188' class=' answer'><span>Interoperability Matrix Tool (IMT)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341334[]' id='answer-id-1335189' class='answer   answerof-341334 ' value='1335189'   \/><label for='answer-id-1335189' id='answer-label-1335189' class=' answer'><span>OneCollect<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341334[]' id='answer-id-1335190' class='answer   answerof-341334 ' value='1335190'   \/><label for='answer-id-1335190' id='answer-label-1335190' class=' answer'><span>Config Advisor<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341334[]' id='answer-id-1335191' class='answer   answerof-341334 ' value='1335191'   \/><label for='answer-id-1335191' id='answer-label-1335191' class=' answer'><span>Hardware Universe (HWU)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-63' style=';'><div id='questionWrap-63'  class='   watupro-question-id-341335'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>63. <\/span>Click the Exhibit button. <br \/>\r<br><br><img decoding=\"async\" width=649 height=167 id=\"\u56fe\u7247 18\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image022-14.jpg\"><br><br \/>\r<br>You are implementing an ONTAP 9.5 AFF A300 SAN cluster with the NVMe, FC, and FCoE protocols. <br \/>\r<br>Referring to the exhibit, which three protocols and physical port pairs are supported? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_63' value='341335' \/><input type='hidden' id='answerType341335' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341335[]' id='answer-id-1335192' class='answer   answerof-341335 ' value='1335192'   \/><label for='answer-id-1335192' id='answer-label-1335192' class=' answer'><span>NVMe on ports 2a\/2b<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341335[]' id='answer-id-1335193' class='answer   answerof-341335 ' value='1335193'   \/><label for='answer-id-1335193' id='answer-label-1335193' class=' answer'><span>FC on ports 2a\/2b<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341335[]' id='answer-id-1335194' class='answer   answerof-341335 ' value='1335194'   \/><label for='answer-id-1335194' id='answer-label-1335194' class=' answer'><span>NVMe on ports Oe\/Of<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341335[]' id='answer-id-1335195' class='answer   answerof-341335 ' value='1335195'   \/><label for='answer-id-1335195' id='answer-label-1335195' class=' answer'><span>FCoE on ports Oe\/Of<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341335[]' id='answer-id-1335196' class='answer   answerof-341335 ' value='1335196'   \/><label for='answer-id-1335196' id='answer-label-1335196' class=' answer'><span>FC on ports Oe\/Of<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-64' style=';'><div id='questionWrap-64'  class='   watupro-question-id-341336'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>64. <\/span>What is a SAN best practice when initially configuring a Linux FC boot LUN?<\/div><input type='hidden' name='question_id[]' id='qID_64' value='341336' \/><input type='hidden' id='answerType341336' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341336[]' id='answer-id-1335197' class='answer   answerof-341336 ' value='1335197'   \/><label for='answer-id-1335197' id='answer-label-1335197' class=' answer'><span>Install the Host Utilities in the guest Linux O<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341336[]' id='answer-id-1335198' class='answer   answerof-341336 ' value='1335198'   \/><label for='answer-id-1335198' id='answer-label-1335198' class=' answer'><span>Map the WWPN of the target.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341336[]' id='answer-id-1335199' class='answer   answerof-341336 ' value='1335199'   \/><label for='answer-id-1335199' id='answer-label-1335199' class=' answer'><span>Disable the HBA port with the host's BIO<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341336[]' id='answer-id-1335200' class='answer   answerof-341336 ' value='1335200'   \/><label for='answer-id-1335200' id='answer-label-1335200' class=' answer'><span>Configure multipath to the LU<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-65' style=';'><div id='questionWrap-65'  class='   watupro-question-id-341337'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>65. <\/span>You create a new iSCSI SVM and secure iSCSI sessions by using both Challenge-Handshake Authentication Protocol (CHAP) and iSCSI Access Control Lists (ACL). <br \/>\r<br>In this scenario, in which two ways are you securing your iSCSI implementation? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_65' value='341337' \/><input type='hidden' id='answerType341337' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341337[]' id='answer-id-1335201' class='answer   answerof-341337 ' value='1335201'   \/><label for='answer-id-1335201' id='answer-label-1335201' class=' answer'><span>CHAP creates a hash value for the username and shared secret.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341337[]' id='answer-id-1335202' class='answer   answerof-341337 ' value='1335202'   \/><label for='answer-id-1335202' id='answer-label-1335202' class=' answer'><span>iSCSI ACLs are applied to the initiator configuration to provide an IP address of the targets.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341337[]' id='answer-id-1335203' class='answer   answerof-341337 ' value='1335203'   \/><label for='answer-id-1335203' id='answer-label-1335203' class=' answer'><span>CHAP encrypts all iSCSI session I\/<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341337[]' id='answer-id-1335204' class='answer   answerof-341337 ' value='1335204'   \/><label for='answer-id-1335204' id='answer-label-1335204' class=' answer'><span>iSCSI ACLs are applied to the target configuration to provide an IP address of the initiators.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-66' style=';'><div id='questionWrap-66'  class='   watupro-question-id-341338'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>66. <\/span>How do you configure the iSCSI-SendTargets datastore when the datastore is provisioned from NetApp storage?<\/div><input type='hidden' name='question_id[]' id='qID_66' value='341338' \/><input type='hidden' id='answerType341338' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341338[]' id='answer-id-1335205' class='answer   answerof-341338 ' value='1335205'   \/><label for='answer-id-1335205' id='answer-label-1335205' class=' answer'><span>You must configure jumbo frames when SendTargets-based iSCSI is used.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341338[]' id='answer-id-1335206' class='answer   answerof-341338 ' value='1335206'   \/><label for='answer-id-1335206' id='answer-label-1335206' class=' answer'><span>Use static discovery to add the target IQ<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341338[]' id='answer-id-1335207' class='answer   answerof-341338 ' value='1335207'   \/><label for='answer-id-1335207' id='answer-label-1335207' class=' answer'><span>Use dynamic discovery to add the target IQ<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341338[]' id='answer-id-1335208' class='answer   answerof-341338 ' value='1335208'   \/><label for='answer-id-1335208' id='answer-label-1335208' class=' answer'><span>You must configure a single protocol on the SVM when SendTargets-based iSCSI is used.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-67' style=';'><div id='questionWrap-67'  class='   watupro-question-id-341339'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>67. <\/span>You are planning to set up a new SAN with an AFF A300 2-node switchless cluster. Your SAN fabric will consist of Cisco MDS9148s switches. <br \/>\r<br>According to NetApp best practices, which two actions would be required to accomplish this task? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_67' value='341339' \/><input type='hidden' id='answerType341339' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341339[]' id='answer-id-1335209' class='answer   answerof-341339 ' value='1335209'   \/><label for='answer-id-1335209' id='answer-label-1335209' class=' answer'><span>Set the switchport speed setting to 16 G<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341339[]' id='answer-id-1335210' class='answer   answerof-341339 ' value='1335210'   \/><label for='answer-id-1335210' id='answer-label-1335210' class=' answer'><span>Use single initiator, multiple target zoning.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341339[]' id='answer-id-1335211' class='answer   answerof-341339 ' value='1335211'   \/><label for='answer-id-1335211' id='answer-label-1335211' class=' answer'><span>Use multiple initiator, single target zoning.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341339[]' id='answer-id-1335212' class='answer   answerof-341339 ' value='1335212'   \/><label for='answer-id-1335212' id='answer-label-1335212' class=' answer'><span>Set the switchport speed to auto negotiate.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-68' style=';'><div id='questionWrap-68'  class='   watupro-question-id-341340'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>68. <\/span>The ESX host reports inconsistent performance for iSCSI-based connectivity. <br \/>\r<br>In this scenario, what would cause this problem?<\/div><input type='hidden' name='question_id[]' id='qID_68' value='341340' \/><input type='hidden' id='answerType341340' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341340[]' id='answer-id-1335213' class='answer   answerof-341340 ' value='1335213'   \/><label for='answer-id-1335213' id='answer-label-1335213' class=' answer'><span>The host and storage are connected to different switches.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341340[]' id='answer-id-1335214' class='answer   answerof-341340 ' value='1335214'   \/><label for='answer-id-1335214' id='answer-label-1335214' class=' answer'><span>The flow control was disabled on the storage.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341340[]' id='answer-id-1335215' class='answer   answerof-341340 ' value='1335215'   \/><label for='answer-id-1335215' id='answer-label-1335215' class=' answer'><span>The hardware initiators were used instead of software.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341340[]' id='answer-id-1335216' class='answer   answerof-341340 ' value='1335216'   \/><label for='answer-id-1335216' id='answer-label-1335216' class=' answer'><span>The flow control is enabled on the storage.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-69' style=';'><div id='questionWrap-69'  class='   watupro-question-id-341341'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>69. <\/span>Click the Exhibit button. <br \/>\r<br><br><img decoding=\"async\" width=649 height=143 id=\"\u56fe\u7247 16\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image024-14.jpg\"><br><br \/>\r<br>An administrator is trying to configure a multiple-hop Cisco MDS switch and is receiving the error shown in the exhibit. <br \/>\r<br>In this scenario, which action will solve this problem?<\/div><input type='hidden' name='question_id[]' id='qID_69' value='341341' \/><input type='hidden' id='answerType341341' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341341[]' id='answer-id-1335217' class='answer   answerof-341341 ' value='1335217'   \/><label for='answer-id-1335217' id='answer-label-1335217' class=' answer'><span>Configure the physical link of interface extl7 as an F_Port.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341341[]' id='answer-id-1335218' class='answer   answerof-341341 ' value='1335218'   \/><label for='answer-id-1335218' id='answer-label-1335218' class=' answer'><span>Configure the external interface to a different virtual SAN (VSAN) on both ends.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341341[]' id='answer-id-1335219' class='answer   answerof-341341 ' value='1335219'   \/><label for='answer-id-1335219' id='answer-label-1335219' class=' answer'><span>Connect the external link to a Cisco MDS switch.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341341[]' id='answer-id-1335220' class='answer   answerof-341341 ' value='1335220'   \/><label for='answer-id-1335220' id='answer-label-1335220' class=' answer'><span>Turn N_Port ID virtualization (NPIV) off.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-70' style=';'><div id='questionWrap-70'  class='   watupro-question-id-341342'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>70. <\/span>What is the supported NVMe OS multipathing stack for VMware ESXi?<\/div><input type='hidden' name='question_id[]' id='qID_70' value='341342' \/><input type='hidden' id='answerType341342' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341342[]' id='answer-id-1335221' class='answer   answerof-341342 ' value='1335221'   \/><label for='answer-id-1335221' id='answer-label-1335221' class=' answer'><span>dm-multipath<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341342[]' id='answer-id-1335222' class='answer   answerof-341342 ' value='1335222'   \/><label for='answer-id-1335222' id='answer-label-1335222' class=' answer'><span>MPIO<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341342[]' id='answer-id-1335223' class='answer   answerof-341342 ' value='1335223'   \/><label for='answer-id-1335223' id='answer-label-1335223' class=' answer'><span>NMP<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341342[]' id='answer-id-1335224' class='answer   answerof-341342 ' value='1335224'   \/><label for='answer-id-1335224' id='answer-label-1335224' class=' answer'><span>PVlinks<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-71' style=';'><div id='questionWrap-71'  class='   watupro-question-id-341343'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>71. <\/span>Which resource would you use to verify whether a specific SAN configuration is supported by NetApp?<\/div><input type='hidden' name='question_id[]' id='qID_71' value='341343' \/><input type='hidden' id='answerType341343' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341343[]' id='answer-id-1335225' class='answer   answerof-341343 ' value='1335225'   \/><label for='answer-id-1335225' id='answer-label-1335225' class=' answer'><span>ONTAP SAN Configuration Guide<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341343[]' id='answer-id-1335226' class='answer   answerof-341343 ' value='1335226'   \/><label for='answer-id-1335226' id='answer-label-1335226' class=' answer'><span>Hardware Universe (HWU)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341343[]' id='answer-id-1335227' class='answer   answerof-341343 ' value='1335227'   \/><label for='answer-id-1335227' id='answer-label-1335227' class=' answer'><span>Active IQ<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341343[]' id='answer-id-1335228' class='answer   answerof-341343 ' value='1335228'   \/><label for='answer-id-1335228' id='answer-label-1335228' class=' answer'><span>Interoperability Matrix Tool (IMT)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-72' style=';'><div id='questionWrap-72'  class='   watupro-question-id-341344'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>72. <\/span>Click the Exhibit button. <br \/>\r<br><br><img decoding=\"async\" width=649 height=465 id=\"\u56fe\u7247 57\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image025-12.jpg\"><br><br \/>\r<br>You have a 2-node cluster in a single-fabric SAN. Host 1 and Host 2 are part of a VMware cluster and access the same LUNs that reside in your NetApp storage. <br \/>\r<br>Referring to the exhibit, what would be a way to test whether the multipathing is properly configured in your environment?<\/div><input type='hidden' name='question_id[]' id='qID_72' value='341344' \/><input type='hidden' id='answerType341344' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341344[]' id='answer-id-1335229' class='answer   answerof-341344 ' value='1335229'   \/><label for='answer-id-1335229' id='answer-label-1335229' class=' answer'><span>Verify whether all destination storage target ports are contained in the same zone as Host 1.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341344[]' id='answer-id-1335230' class='answer   answerof-341344 ' value='1335230'   \/><label for='answer-id-1335230' id='answer-label-1335230' class=' answer'><span>Administratively set ports 0a and 0c on Controller 1 to the offline setting.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341344[]' id='answer-id-1335231' class='answer   answerof-341344 ' value='1335231'   \/><label for='answer-id-1335231' id='answer-label-1335231' class=' answer'><span>Disconnect Host 1 port and verify whether Host 2 is still able to run the VMs.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341344[]' id='answer-id-1335232' class='answer   answerof-341344 ' value='1335232'   \/><label for='answer-id-1335232' id='answer-label-1335232' class=' answer'><span>Power off the SAN switch.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-73' style=';'><div id='questionWrap-73'  class='   watupro-question-id-341345'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>73. <\/span>An administrator configures NVMe within an SVM for a test environment. The administrator creates an NVMe namespace and an NVMe subsystem. The administrator then maps the namespace to the subsystem. <br \/>\r<br>However, when the administrator establishes a connection to a supported host, the following error message appears: No discovery log entries to fetch. <br \/>\r<br>What is the solution to this error?<\/div><input type='hidden' name='question_id[]' id='qID_73' value='341345' \/><input type='hidden' id='answerType341345' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341345[]' id='answer-id-1335233' class='answer   answerof-341345 ' value='1335233'   \/><label for='answer-id-1335233' id='answer-label-1335233' class=' answer'><span>Add the host WWPN to the subsystem<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341345[]' id='answer-id-1335234' class='answer   answerof-341345 ' value='1335234'   \/><label for='answer-id-1335234' id='answer-label-1335234' class=' answer'><span>Disable the host HBA and re-enable it to clear the buffers<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341345[]' id='answer-id-1335235' class='answer   answerof-341345 ' value='1335235'   \/><label for='answer-id-1335235' id='answer-label-1335235' class=' answer'><span>Add the host NQN to the subsystem<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341345[]' id='answer-id-1335236' class='answer   answerof-341345 ' value='1335236'   \/><label for='answer-id-1335236' id='answer-label-1335236' class=' answer'><span>Use the nvme ns-rescan \/dev\/nvme0 command to rescan the bus<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-74' style=';'><div id='questionWrap-74'  class='   watupro-question-id-341346'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>74. <\/span>After the addition of extra DS224C disk shelves, you notice that the output of the system node run - node node_1 sysconfig command shows Mixed-path. You need to investigate why the additional shelves are providing this error. <br \/>\r<br>In this scenario, which two tools would help diagnose this issue? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_74' value='341346' \/><input type='hidden' id='answerType341346' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341346[]' id='answer-id-1335237' class='answer   answerof-341346 ' value='1335237'   \/><label for='answer-id-1335237' id='answer-label-1335237' class=' answer'><span>Config Advisor<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341346[]' id='answer-id-1335238' class='answer   answerof-341346 ' value='1335238'   \/><label for='answer-id-1335238' id='answer-label-1335238' class=' answer'><span>Active IQ<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341346[]' id='answer-id-1335239' class='answer   answerof-341346 ' value='1335239'   \/><label for='answer-id-1335239' id='answer-label-1335239' class=' answer'><span>Hardware Universe (HWU)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341346[]' id='answer-id-1335240' class='answer   answerof-341346 ' value='1335240'   \/><label for='answer-id-1335240' id='answer-label-1335240' class=' answer'><span>Interoperability Matrix Tool (IMT)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-75' style=';'><div id='questionWrap-75'  class='   watupro-question-id-341347'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>75. <\/span>A customer's NetApp infrastructure is reaching end-of-life (EOL), and they want to inventory their NetApp cluster. The customer wants to make sure that the proposed technical refresh satisfies their growing data demands. <br \/>\r<br>Which two tools would you use to help with this recommendation? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_75' value='341347' \/><input type='hidden' id='answerType341347' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341347[]' id='answer-id-1335241' class='answer   answerof-341347 ' value='1335241'   \/><label for='answer-id-1335241' id='answer-label-1335241' class=' answer'><span>Upgrade Advisor<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341347[]' id='answer-id-1335242' class='answer   answerof-341347 ' value='1335242'   \/><label for='answer-id-1335242' id='answer-label-1335242' class=' answer'><span>OneCollect<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341347[]' id='answer-id-1335243' class='answer   answerof-341347 ' value='1335243'   \/><label for='answer-id-1335243' id='answer-label-1335243' class=' answer'><span>Config Advisor<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341347[]' id='answer-id-1335244' class='answer   answerof-341347 ' value='1335244'   \/><label for='answer-id-1335244' id='answer-label-1335244' class=' answer'><span>Active IQ<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-76' style=';'><div id='questionWrap-76'  class='   watupro-question-id-341348'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>76. <\/span>A customer is expanding an ONTAP 9.4 switchless 2-node FAS2750 cluster. Two AFF A220 nodes will be added to the cluster. <br \/>\r<br>In addition to the cluster nodes, what else is required to perform the cluster expansion?<\/div><input type='hidden' name='question_id[]' id='qID_76' value='341348' \/><input type='hidden' id='answerType341348' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341348[]' id='answer-id-1335245' class='answer   answerof-341348 ' value='1335245'   \/><label for='answer-id-1335245' id='answer-label-1335245' class=' answer'><span>Additional management switches are required.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341348[]' id='answer-id-1335246' class='answer   answerof-341348 ' value='1335246'   \/><label for='answer-id-1335246' id='answer-label-1335246' class=' answer'><span>An upgrade to ONTAP 9.5 is required.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341348[]' id='answer-id-1335247' class='answer   answerof-341348 ' value='1335247'   \/><label for='answer-id-1335247' id='answer-label-1335247' class=' answer'><span>Cluster switches are required.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341348[]' id='answer-id-1335248' class='answer   answerof-341348 ' value='1335248'   \/><label for='answer-id-1335248' id='answer-label-1335248' class=' answer'><span>Additional DS224C shelves are needed.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-77' style=';'><div id='questionWrap-77'  class='   watupro-question-id-341349'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>77. <\/span>What is the recommended minimum of data LIFs per node for iSCSI in a dual-fabric configuration with four SVMs?<\/div><input type='hidden' name='question_id[]' id='qID_77' value='341349' \/><input type='hidden' id='answerType341349' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341349[]' id='answer-id-1335249' class='answer   answerof-341349 ' value='1335249'   \/><label for='answer-id-1335249' id='answer-label-1335249' class=' answer'><span>8<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341349[]' id='answer-id-1335250' class='answer   answerof-341349 ' value='1335250'   \/><label for='answer-id-1335250' id='answer-label-1335250' class=' answer'><span>12<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341349[]' id='answer-id-1335251' class='answer   answerof-341349 ' value='1335251'   \/><label for='answer-id-1335251' id='answer-label-1335251' class=' answer'><span>16<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341349[]' id='answer-id-1335252' class='answer   answerof-341349 ' value='1335252'   \/><label for='answer-id-1335252' id='answer-label-1335252' class=' answer'><span>4<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-78' style=';'><div id='questionWrap-78'  class='   watupro-question-id-341350'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>78. <\/span>Click the Exhibit button. <br \/>\r<br><br><img decoding=\"async\" width=649 height=338 id=\"\u56fe\u7247 15\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2024\/06\/image026-12.jpg\"><br><br \/>\r<br>The LUN that is shown in the exhibit is mounted by a Windows 2016 server. <br \/>\r<br>In this scenario, which two statements are correct? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_78' value='341350' \/><input type='hidden' id='answerType341350' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341350[]' id='answer-id-1335253' class='answer   answerof-341350 ' value='1335253'   \/><label for='answer-id-1335253' id='answer-label-1335253' class=' answer'><span>The LUN has misaligned I\/<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341350[]' id='answer-id-1335254' class='answer   answerof-341350 ' value='1335254'   \/><label for='answer-id-1335254' id='answer-label-1335254' class=' answer'><span>The LUN has aligned I\/<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341350[]' id='answer-id-1335255' class='answer   answerof-341350 ' value='1335255'   \/><label for='answer-id-1335255' id='answer-label-1335255' class=' answer'><span>The LUN's space is reserved.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341350[]' id='answer-id-1335256' class='answer   answerof-341350 ' value='1335256'   \/><label for='answer-id-1335256' id='answer-label-1335256' class=' answer'><span>The LUN's space is not reserved.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-79' style=';'><div id='questionWrap-79'  class='   watupro-question-id-341351'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>79. <\/span>A customer recently added two nodes with FC ports to a 4-node cluster. <br \/>\r<br>Which SVM configuration is needed before the customer creates LUNs on the new nodes?<\/div><input type='hidden' name='question_id[]' id='qID_79' value='341351' \/><input type='hidden' id='answerType341351' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341351[]' id='answer-id-1335257' class='answer   answerof-341351 ' value='1335257'   \/><label for='answer-id-1335257' id='answer-label-1335257' class=' answer'><span>The FC service needs to be enabled on the data SV<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341351[]' id='answer-id-1335258' class='answer   answerof-341351 ' value='1335258'   \/><label for='answer-id-1335258' id='answer-label-1335258' class=' answer'><span>The existing LIFs need to be migrated to the new nodes.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341351[]' id='answer-id-1335259' class='answer   answerof-341351 ' value='1335259'   \/><label for='answer-id-1335259' id='answer-label-1335259' class=' answer'><span>New FC LIFs need to be created on the cluster SV<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341351[]' id='answer-id-1335260' class='answer   answerof-341351 ' value='1335260'   \/><label for='answer-id-1335260' id='answer-label-1335260' class=' answer'><span>New FC LIFs need to be created on the new nodes.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-80' style=';'><div id='questionWrap-80'  class='   watupro-question-id-341352'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>80. <\/span>You are configuring both NVMe and FC on the same AFF A700 2-node ONTAP 9.5 cluster. You are also configuring both protocols on the same FC fabric using the same A700 HBA ports. <br \/>\r<br>In this scenario, which three configurations are supported? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_80' value='341352' \/><input type='hidden' id='answerType341352' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341352[]' id='answer-id-1335261' class='answer   answerof-341352 ' value='1335261'   \/><label for='answer-id-1335261' id='answer-label-1335261' class=' answer'><span>16 GB HBAs<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341352[]' id='answer-id-1335262' class='answer   answerof-341352 ' value='1335262'   \/><label for='answer-id-1335262' id='answer-label-1335262' class=' answer'><span>8 GB HBAs<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341352[]' id='answer-id-1335263' class='answer   answerof-341352 ' value='1335263'   \/><label for='answer-id-1335263' id='answer-label-1335263' class=' answer'><span>16 GB fabrics<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341352[]' id='answer-id-1335264' class='answer   answerof-341352 ' value='1335264'   \/><label for='answer-id-1335264' id='answer-label-1335264' class=' answer'><span>32 GB HBAs<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341352[]' id='answer-id-1335265' class='answer   answerof-341352 ' value='1335265'   \/><label for='answer-id-1335265' id='answer-label-1335265' class=' answer'><span>32 GB fabrics<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-81' style=';'><div id='questionWrap-81'  class='   watupro-question-id-341353'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>81. <\/span>An administrator needs to determine the maximum volume size that is supported per operating system. <br \/>\r<br>Which resource has this information?<\/div><input type='hidden' name='question_id[]' id='qID_81' value='341353' \/><input type='hidden' id='answerType341353' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341353[]' id='answer-id-1335266' class='answer   answerof-341353 ' value='1335266'   \/><label for='answer-id-1335266' id='answer-label-1335266' class=' answer'><span>Config Advisor<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341353[]' id='answer-id-1335267' class='answer   answerof-341353 ' value='1335267'   \/><label for='answer-id-1335267' id='answer-label-1335267' class=' answer'><span>OneCollect<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341353[]' id='answer-id-1335268' class='answer   answerof-341353 ' value='1335268'   \/><label for='answer-id-1335268' id='answer-label-1335268' class=' answer'><span>Interoperability Matrix Tool (IMT)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341353[]' id='answer-id-1335269' class='answer   answerof-341353 ' value='1335269'   \/><label for='answer-id-1335269' id='answer-label-1335269' class=' answer'><span>Hardware Universe (HWU)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-82' style=';'><div id='questionWrap-82'  class='   watupro-question-id-341354'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>82. <\/span>An administrator is adding new hosts to a vSphere cluster. The cluster uses the FC protocol to connect to a NetApp cluster. The administrator wants to configure the multipathing for the ESXi host. <br \/>\r<br>Which NetApp tool should be used to accomplish this task?<\/div><input type='hidden' name='question_id[]' id='qID_82' value='341354' \/><input type='hidden' id='answerType341354' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341354[]' id='answer-id-1335270' class='answer   answerof-341354 ' value='1335270'   \/><label for='answer-id-1335270' id='answer-label-1335270' class=' answer'><span>OnCommand System Manager (OCSM)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341354[]' id='answer-id-1335271' class='answer   answerof-341354 ' value='1335271'   \/><label for='answer-id-1335271' id='answer-label-1335271' class=' answer'><span>Host Utilities<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341354[]' id='answer-id-1335272' class='answer   answerof-341354 ' value='1335272'   \/><label for='answer-id-1335272' id='answer-label-1335272' class=' answer'><span>SnapCenter plug-in<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341354[]' id='answer-id-1335273' class='answer   answerof-341354 ' value='1335273'   \/><label for='answer-id-1335273' id='answer-label-1335273' class=' answer'><span>NetApp Virtual Storage Console (VSC)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-83' style=';'><div id='questionWrap-83'  class='   watupro-question-id-341355'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>83. <\/span>An administrator is asked to configure NVMe on an ONTAP 9.5 cluster for host access. <br \/>\r<br>Which three steps must the administrator perform to accomplish this task? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_83' value='341355' \/><input type='hidden' id='answerType341355' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341355[]' id='answer-id-1335274' class='answer   answerof-341355 ' value='1335274'   \/><label for='answer-id-1335274' id='answer-label-1335274' class=' answer'><span>Create a namespace<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341355[]' id='answer-id-1335275' class='answer   answerof-341355 ' value='1335275'   \/><label for='answer-id-1335275' id='answer-label-1335275' class=' answer'><span>Provision a subsystem<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341355[]' id='answer-id-1335276' class='answer   answerof-341355 ' value='1335276'   \/><label for='answer-id-1335276' id='answer-label-1335276' class=' answer'><span>Configure the FC port<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341355[]' id='answer-id-1335277' class='answer   answerof-341355 ' value='1335277'   \/><label for='answer-id-1335277' id='answer-label-1335277' class=' answer'><span>Gather the IQN from the host initiator software<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341355[]' id='answer-id-1335278' class='answer   answerof-341355 ' value='1335278'   \/><label for='answer-id-1335278' id='answer-label-1335278' class=' answer'><span>Gather the NQN from the host system<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-84' style=';'><div id='questionWrap-84'  class='   watupro-question-id-341356'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>84. <\/span>A user cannot add more than one NVMe data LIF in ONTAP 9.4 on an SVM with a data protocol parameter set to nvme. <br \/>\r<br>In this scenario, what is the problem?<\/div><input type='hidden' name='question_id[]' id='qID_84' value='341356' \/><input type='hidden' id='answerType341356' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341356[]' id='answer-id-1335279' class='answer   answerof-341356 ' value='1335279'   \/><label for='answer-id-1335279' id='answer-label-1335279' class=' answer'><span>The SVM data protocol should be set to F<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341356[]' id='answer-id-1335280' class='answer   answerof-341356 ' value='1335280'   \/><label for='answer-id-1335280' id='answer-label-1335280' class=' answer'><span>The NVMe namespace is not created.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341356[]' id='answer-id-1335281' class='answer   answerof-341356 ' value='1335281'   \/><label for='answer-id-1335281' id='answer-label-1335281' class=' answer'><span>A demo license is used.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341356[]' id='answer-id-1335282' class='answer   answerof-341356 ' value='1335282'   \/><label for='answer-id-1335282' id='answer-label-1335282' class=' answer'><span>Only one NVMe data LIF can be configured per SV<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-85' style=';'><div id='questionWrap-85'  class='   watupro-question-id-341357'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>85. <\/span>An administrator has six VMware hosts, each with dual HBAs that are connected to a dual fabric using single initiator multiple target zoning. Four nodes are being added to the existing 4-node ONTAP cluster. <br \/>\r<br>In this scenario, what is the minimum number of FC zones that need to be updated on each fabric switch?<\/div><input type='hidden' name='question_id[]' id='qID_85' value='341357' \/><input type='hidden' id='answerType341357' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341357[]' id='answer-id-1335283' class='answer   answerof-341357 ' value='1335283'   \/><label for='answer-id-1335283' id='answer-label-1335283' class=' answer'><span>6<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341357[]' id='answer-id-1335284' class='answer   answerof-341357 ' value='1335284'   \/><label for='answer-id-1335284' id='answer-label-1335284' class=' answer'><span>8<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341357[]' id='answer-id-1335285' class='answer   answerof-341357 ' value='1335285'   \/><label for='answer-id-1335285' id='answer-label-1335285' class=' answer'><span>4<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-341357[]' id='answer-id-1335286' class='answer   answerof-341357 ' value='1335286'   \/><label for='answer-id-1335286' id='answer-label-1335286' class=' answer'><span>2<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-86' style=';'><div id='questionWrap-86'  class='   watupro-question-id-341358'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>86. <\/span>An administrator has an AFF A200 cluster at their primary site that is used for FC connectivity to servers. For disaster recovery purposes they want to start replicating their data to another AFF A3Q0 cluster In a secondary location. <br \/>\r<br>The AFF A300 is In a site that has no FC or FCoE capable switches, and is currently only used for CIFS data. A cluster peering relationship already exists between the two clusters. <br \/>\r<br>Which three additional actions are needed for the data to be ready for access from hosts at the secondary site? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_86' value='341358' \/><input type='hidden' id='answerType341358' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341358[]' id='answer-id-1335287' class='answer   answerof-341358 ' value='1335287'   \/><label for='answer-id-1335287' id='answer-label-1335287' class=' answer'><span>Create zones with the appropriate initiators and targets for the secondary site.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341358[]' id='answer-id-1335288' class='answer   answerof-341358 ' value='1335288'   \/><label for='answer-id-1335288' id='answer-label-1335288' class=' answer'><span>Enable the iSCSI service on the SVM at the secondary site.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341358[]' id='answer-id-1335289' class='answer   answerof-341358 ' value='1335289'   \/><label for='answer-id-1335289' id='answer-label-1335289' class=' answer'><span>Replicate the data from the primary site to the secondary site with SnapMirror.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341358[]' id='answer-id-1335290' class='answer   answerof-341358 ' value='1335290'   \/><label for='answer-id-1335290' id='answer-label-1335290' class=' answer'><span>Create new iSCSI igroups for LUN mapping.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-341358[]' id='answer-id-1335291' class='answer   answerof-341358 ' value='1335291'   \/><label for='answer-id-1335291' id='answer-label-1335291' class=' answer'><span>Enable the iSCSI service on the SVM at the primary site.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div style='display:none' id='question-87'>\n\t<div class='question-content'>\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\" alt=\"Loading...\" title=\"Loading...\" \/>&nbsp;Loading...\t<\/div>\n<\/div>\n\n<br \/>\n\t\n\t\t\t<div class=\"watupro_buttons flex \" id=\"watuPROButtons8763\" >\n\t\t  <div id=\"prev-question\" style=\"display:none;\"><input type=\"button\" value=\"&lt; Previous\" onclick=\"WatuPRO.nextQuestion(event, 'previous');\"\/><\/div>\t\t  \t\t  \t\t   \n\t\t   \t  \t\t<div><input type=\"button\" name=\"action\" class=\"watupro-submit-button\" onclick=\"WatuPRO.submitResult(event)\" id=\"action-button\" value=\"View Results\"  \/>\n\t\t<\/div>\n\t\t<\/div>\n\t\t\n\t<input type=\"hidden\" name=\"quiz_id\" value=\"8763\" id=\"watuPROExamID\"\/>\n\t<input type=\"hidden\" name=\"start_time\" id=\"startTime\" value=\"2026-05-03 12:15:41\" \/>\n\t<input type=\"hidden\" name=\"start_timestamp\" id=\"startTimeStamp\" value=\"1777810541\" \/>\n\t<input type=\"hidden\" name=\"question_ids\" value=\"\" \/>\n\t<input type=\"hidden\" name=\"watupro_questions\" value=\"341273:1334939,1334940,1334941,1334942 | 341274:1334943,1334944,1334945,1334946 | 341275:1334947,1334948,1334949,1334950 | 341276:1334951,1334952,1334953,1334954 | 341277:1334955,1334956,1334957,1334958 | 341278:1334959,1334960,1334961,1334962 | 341279:1334963,1334964,1334965,1334966 | 341280:1334967,1334968,1334969,1334970,1334971 | 341281:1334972,1334973,1334974,1334975 | 341282:1334976,1334977,1334978,1334979 | 341283:1334980,1334981,1334982,1334983 | 341284:1334984,1334985,1334986,1334987 | 341285:1334988,1334989,1334990,1334991 | 341286:1334992,1334993,1334994,1334995 | 341287:1334996,1334997,1334998,1334999 | 341288:1335000,1335001,1335002,1335003 | 341289:1335004,1335005,1335006,1335007 | 341290:1335008,1335009,1335010,1335011 | 341291:1335012,1335013,1335014,1335015 | 341292:1335016,1335017,1335018,1335019 | 341293:1335020,1335021,1335022,1335023,1335024 | 341294:1335025,1335026,1335027,1335028 | 341295:1335029,1335030,1335031,1335032 | 341296:1335033,1335034,1335035,1335036 | 341297:1335037,1335038,1335039,1335040 | 341298:1335041,1335042,1335043,1335044 | 341299:1335045,1335046,1335047,1335048 | 341300:1335049,1335050,1335051,1335052 | 341301:1335053,1335054,1335055,1335056 | 341302:1335057,1335058,1335059,1335060 | 341303:1335061,1335062,1335063,1335064 | 341304:1335065,1335066,1335067,1335068 | 341305:1335069,1335070,1335071,1335072 | 341306:1335073,1335074,1335075,1335076 | 341307:1335077,1335078,1335079,1335080 | 341308:1335081,1335082,1335083,1335084 | 341309:1335085,1335086,1335087,1335088 | 341310:1335089,1335090,1335091,1335092 | 341311:1335093,1335094,1335095,1335096 | 341312:1335097,1335098,1335099,1335100 | 341313:1335101,1335102,1335103,1335104 | 341314:1335105,1335106,1335107,1335108 | 341315:1335109,1335110,1335111,1335112,1335113 | 341316:1335114,1335115,1335116,1335117 | 341317:1335118,1335119,1335120,1335121 | 341318:1335122,1335123,1335124,1335125 | 341319:1335126,1335127,1335128,1335129 | 341320:1335130,1335131,1335132,1335133 | 341321:1335134,1335135,1335136,1335137 | 341322:1335138,1335139,1335140,1335141 | 341323:1335142,1335143,1335144,1335145 | 341324:1335146,1335147,1335148,1335149 | 341325:1335150,1335151,1335152,1335153 | 341326:1335154,1335155,1335156,1335157 | 341327:1335158,1335159,1335160,1335161 | 341328:1335162,1335163,1335164,1335165 | 341329:1335166,1335167,1335168,1335169,1335170 | 341330:1335171,1335172,1335173,1335174 | 341331:1335175,1335176,1335177,1335178,1335179 | 341332:1335180,1335181,1335182,1335183 | 341333:1335184,1335185,1335186,1335187 | 341334:1335188,1335189,1335190,1335191 | 341335:1335192,1335193,1335194,1335195,1335196 | 341336:1335197,1335198,1335199,1335200 | 341337:1335201,1335202,1335203,1335204 | 341338:1335205,1335206,1335207,1335208 | 341339:1335209,1335210,1335211,1335212 | 341340:1335213,1335214,1335215,1335216 | 341341:1335217,1335218,1335219,1335220 | 341342:1335221,1335222,1335223,1335224 | 341343:1335225,1335226,1335227,1335228 | 341344:1335229,1335230,1335231,1335232 | 341345:1335233,1335234,1335235,1335236 | 341346:1335237,1335238,1335239,1335240 | 341347:1335241,1335242,1335243,1335244 | 341348:1335245,1335246,1335247,1335248 | 341349:1335249,1335250,1335251,1335252 | 341350:1335253,1335254,1335255,1335256 | 341351:1335257,1335258,1335259,1335260 | 341352:1335261,1335262,1335263,1335264,1335265 | 341353:1335266,1335267,1335268,1335269 | 341354:1335270,1335271,1335272,1335273 | 341355:1335274,1335275,1335276,1335277,1335278 | 341356:1335279,1335280,1335281,1335282 | 341357:1335283,1335284,1335285,1335286 | 341358:1335287,1335288,1335289,1335290,1335291\" \/>\n\t<input type=\"hidden\" name=\"no_ajax\" value=\"0\">\t\t\t<\/form>\n\t<p>&nbsp;<\/p>\n<\/div>\n\n<script type=\"text\/javascript\">\n\/\/jQuery(document).ready(function(){\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \t\nvar question_ids = \"341273,341274,341275,341276,341277,341278,341279,341280,341281,341282,341283,341284,341285,341286,341287,341288,341289,341290,341291,341292,341293,341294,341295,341296,341297,341298,341299,341300,341301,341302,341303,341304,341305,341306,341307,341308,341309,341310,341311,341312,341313,341314,341315,341316,341317,341318,341319,341320,341321,341322,341323,341324,341325,341326,341327,341328,341329,341330,341331,341332,341333,341334,341335,341336,341337,341338,341339,341340,341341,341342,341343,341344,341345,341346,341347,341348,341349,341350,341351,341352,341353,341354,341355,341356,341357,341358\";\nWatuPROSettings[8763] = {};\nWatuPRO.qArr = question_ids.split(',');\nWatuPRO.exam_id = 8763;\t    \nWatuPRO.post_id = 82702;\nWatuPRO.store_progress = 0;\nWatuPRO.curCatPage = 1;\nWatuPRO.requiredIDs=\"0\".split(\",\");\nWatuPRO.hAppID = \"0.06201900 1777810541\";\nvar url = \"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/show_exam.php\";\nWatuPRO.examMode = 1;\nWatuPRO.siteURL=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-admin\/admin-ajax.php\";\nWatuPRO.emailIsNotRequired = 0;\nWatuPROIntel.init(8763);\nWatuPRO.inCategoryPages=1;});    \t \n<\/script>\n<p>\u00a0<\/p>\n\n\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[127,2972],"tags":[17080,17078],"class_list":["post-82702","post","type-post","status-publish","format-standard","hentry","category-network-appliance","category-network-appliance-ncie-san-specialist-certification","tag-netapp-ncie-san-ontap-certification-2","tag-ns0-520-dumps-updated"],"_links":{"self":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/82702","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/comments?post=82702"}],"version-history":[{"count":1,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/82702\/revisions"}],"predecessor-version":[{"id":82703,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/82702\/revisions\/82703"}],"wp:attachment":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/media?parent=82702"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/categories?post=82702"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/tags?post=82702"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}