{"id":788,"date":"2018-07-28T08:11:20","date_gmt":"2018-07-28T08:11:20","guid":{"rendered":"https:\/\/dumps.dumpsbase.com\/?p=788"},"modified":"2019-03-04T05:27:54","modified_gmt":"2019-03-04T05:27:54","slug":"ns0-507-network-appliance-ncie-san-exam-questions-share-free","status":"publish","type":"post","link":"https:\/\/www.dumpsbase.com\/freedumps\/ns0-507-network-appliance-ncie-san-exam-questions-share-free.html","title":{"rendered":"NS0-507 Network Appliance NCIE-SAN Exam Questions Share Free"},"content":{"rendered":"<p>Have you passed your NS0-507 exam test? The main difference between NS0-506 and NS0-507 is that NS0-506 focused on clustered Data ONTAP and NS0-507 focuses on ONTAP 9. There is no good way for you to prepare for your NS0-507 Network Appliance NCIE-SAN certification exam.<\/p>\n<p><span style=\"background-color: #99cc00;\"><em><strong><span style=\"font-size: 14pt; background-color: #99cc00;\">Go to your NS0-507 exam questions now. Test begin now!<\/span><\/strong><\/em><\/span><\/p>\n<script>\n\t  window.fbAsyncInit = function() {\n\t    FB.init({\n\t      appId            : '622169541470367',\n\t      autoLogAppEvents : true,\n\t      xfbml            : true,\n\t      version          : 'v3.1'\n\t    });\n\t  };\n\t\n\t  (function(d, s, id){\n\t     var js, fjs = d.getElementsByTagName(s)[0];\n\t     if (d.getElementById(id)) {return;}\n\t     js = d.createElement(s); js.id = id;\n\t     js.src = \"https:\/\/connect.facebook.net\/en_US\/sdk.js\";\n\t     fjs.parentNode.insertBefore(js, fjs);\n\t   }(document, 'script', 'facebook-jssdk'));\n\t<\/script><script type=\"text\/javascript\" >\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \nif(!window.jQuery) alert(\"The important jQuery library is not properly loaded in your site. Your WordPress theme is probably missing the essential wp_head() call. You can switch to another theme and you will see that the plugin works fine and this notice disappears. If you are still not sure what to do you can contact us for help.\");\n});\n<\/script>  \n  \n<div  id=\"watupro_quiz\" class=\"quiz-area single-page-quiz\">\n<p id=\"submittingExam468\" style=\"display:none;text-align:center;\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\"><\/p>\n\n<div class=\"watupro-exam-description\" id=\"description-quiz-468\"><\/div>\n\n<form action=\"\" method=\"post\" class=\"quiz-form\" id=\"quiz-468\"  enctype=\"multipart\/form-data\" >\n<div class='watu-question ' id='question-1' style=';'><div id='questionWrap-1'  class='   watupro-question-id-9022'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>1. <\/span>Referring to the exhibit, you see an FC SAN configuration that uses multiple fabrics and the best practice Implementation. <br \/>\r<br>How many paths per LUN do you expect the host to see if the cable 0c connecting controller 2 to fabric 1 is pulled out for connectivity redundancy testing? <br \/>\r<br><br><img decoding=\"async\" width=410 height=299 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/NS0-507%20V8.files\/image003.jpg\" v:shapes=\"_x0000_i1026\"><br><\/div><input type='hidden' name='question_id[]' id='qID_1' value='9022' \/><input type='hidden' id='answerType9022' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9022[]' id='answer-id-37384' class='answer   answerof-9022 ' value='37384'   \/><label for='answer-id-37384' id='answer-label-37384' class=' answer'><span>6<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9022[]' id='answer-id-37385' class='answer   answerof-9022 ' value='37385'   \/><label for='answer-id-37385' id='answer-label-37385' class=' answer'><span>14<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9022[]' id='answer-id-37386' class='answer   answerof-9022 ' value='37386'   \/><label for='answer-id-37386' id='answer-label-37386' class=' answer'><span>12<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9022[]' id='answer-id-37387' class='answer   answerof-9022 ' value='37387'   \/><label for='answer-id-37387' id='answer-label-37387' class=' answer'><span>7<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-2' style=';'><div id='questionWrap-2'  class='   watupro-question-id-9023'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>2. <\/span>You successfully migrated LUNs that are accessed over FC from a 7-Mode system to ONTAP 9.1. Your windows Server 2012 is unable to see the new LUNs. <br \/>\r<br>What are three reasons for this problem? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_2' value='9023' \/><input type='hidden' id='answerType9023' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9023[]' id='answer-id-37388' class='answer   answerof-9023 ' value='37388'   \/><label for='answer-id-37388' id='answer-label-37388' class=' answer'><span>The IQN is not included in the igroup.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9023[]' id='answer-id-37389' class='answer   answerof-9023 ' value='37389'   \/><label for='answer-id-37389' id='answer-label-37389' class=' answer'><span>You have no port sets.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9023[]' id='answer-id-37390' class='answer   answerof-9023 ' value='37390'   \/><label for='answer-id-37390' id='answer-label-37390' class=' answer'><span>NPIV is not enabled on the switch.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9023[]' id='answer-id-37391' class='answer   answerof-9023 ' value='37391'   \/><label for='answer-id-37391' id='answer-label-37391' class=' answer'><span>The host is directly attached to the cluster nodes.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9023[]' id='answer-id-37392' class='answer   answerof-9023 ' value='37392'   \/><label for='answer-id-37392' id='answer-label-37392' class=' answer'><span>Switch zoning is misconfigured.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-3' style=';'><div id='questionWrap-3'  class='   watupro-question-id-9024'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>3. <\/span>In a new SAN installation, which three components do you verify in the IMT for a supported solution? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_3' value='9024' \/><input type='hidden' id='answerType9024' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9024[]' id='answer-id-37393' class='answer   answerof-9024 ' value='37393'   \/><label for='answer-id-37393' id='answer-label-37393' class=' answer'><span>HBA driver<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9024[]' id='answer-id-37394' class='answer   answerof-9024 ' value='37394'   \/><label for='answer-id-37394' id='answer-label-37394' class=' answer'><span>host memory<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9024[]' id='answer-id-37395' class='answer   answerof-9024 ' value='37395'   \/><label for='answer-id-37395' id='answer-label-37395' class=' answer'><span>host OS patch level or Service Pack<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9024[]' id='answer-id-37396' class='answer   answerof-9024 ' value='37396'   \/><label for='answer-id-37396' id='answer-label-37396' class=' answer'><span>application patch level<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9024[]' id='answer-id-37397' class='answer   answerof-9024 ' value='37397'   \/><label for='answer-id-37397' id='answer-label-37397' class=' answer'><span>switch firmware<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-4' style=';'><div id='questionWrap-4'  class='   watupro-question-id-9025'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>4. <\/span>You are performing storage failover testing on a 2-node FAS2650 cluster named cl01. A Windows Server 2012R2 host has 10 FC LUNs mapped from the cluster. After Cl01-01 takes over Cl01-02, the windows host loses access to all of its LUNs. <br \/>\r<br>Which statement describes what is happening in this scenario?<\/div><input type='hidden' name='question_id[]' id='qID_4' value='9025' \/><input type='hidden' id='answerType9025' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9025[]' id='answer-id-37398' class='answer   answerof-9025 ' value='37398'   \/><label for='answer-id-37398' id='answer-label-37398' class=' answer'><span>Switch zoning does not exist between the windows initiators and the Cl01-02 targets<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9025[]' id='answer-id-37399' class='answer   answerof-9025 ' value='37399'   \/><label for='answer-id-37399' id='answer-label-37399' class=' answer'><span>NPIV is not enabled on the cluster<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9025[]' id='answer-id-37400' class='answer   answerof-9025 ' value='37400'   \/><label for='answer-id-37400' id='answer-label-37400' class=' answer'><span>Switch zoning does not exist between the windows initiators and the Cl01-01<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9025[]' id='answer-id-37401' class='answer   answerof-9025 ' value='37401'   \/><label for='answer-id-37401' id='answer-label-37401' class=' answer'><span>NPIV is not enabled on the FC switches<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-5' style=';'><div id='questionWrap-5'  class='   watupro-question-id-9026'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>5. <\/span>Which two actions are performed by the windows Unified Host Utilities 7.0 installation? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_5' value='9026' \/><input type='hidden' id='answerType9026' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9026[]' id='answer-id-37402' class='answer   answerof-9026 ' value='37402'   \/><label for='answer-id-37402' id='answer-label-37402' class=' answer'><span>Create the SVMs and the LUNs in ONTAP<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9026[]' id='answer-id-37403' class='answer   answerof-9026 ' value='37403'   \/><label for='answer-id-37403' id='answer-label-37403' class=' answer'><span>Set the parameters on the host to enable a connection to Netapp storage over SAN protocols<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9026[]' id='answer-id-37404' class='answer   answerof-9026 ' value='37404'   \/><label for='answer-id-37404' id='answer-label-37404' class=' answer'><span>Create zoning on the switch between the host and the Netapp SAN cluster<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9026[]' id='answer-id-37405' class='answer   answerof-9026 ' value='37405'   \/><label for='answer-id-37405' id='answer-label-37405' class=' answer'><span>Set the parameters for certain host bus adapters<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-6' style=';'><div id='questionWrap-6'  class='   watupro-question-id-9027'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>6. <\/span>You are migrating data from a foreign array into an existing 2-node AFF300 ONTAP cluster using Foreign LUN import. All existing FC ports are currently in use for FC host connectivity on the Netapp cluster. <br \/>\r<br>Which two statements are correct in this scenario? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_6' value='9027' \/><input type='hidden' id='answerType9027' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9027[]' id='answer-id-37406' class='answer   answerof-9027 ' value='37406'   \/><label for='answer-id-37406' id='answer-label-37406' class=' answer'><span>Add FC HBA cards to the ONTAP cluster to allow for additional initiators.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9027[]' id='answer-id-37407' class='answer   answerof-9027 ' value='37407'   \/><label for='answer-id-37407' id='answer-label-37407' class=' answer'><span>You can change the personality of one of the existing FC ports on the AFF A300 from initiator to target.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9027[]' id='answer-id-37408' class='answer   answerof-9027 ' value='37408'   \/><label for='answer-id-37408' id='answer-label-37408' class=' answer'><span>You can change the personality of one of the existing FC ports on the AFF A300 from target to initiator.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9027[]' id='answer-id-37409' class='answer   answerof-9027 ' value='37409'   \/><label for='answer-id-37409' id='answer-label-37409' class=' answer'><span>Add FC HBA cards to the ONTAP cluster to allow for additional targets.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-7' style=';'><div id='questionWrap-7'  class='   watupro-question-id-9028'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>7. <\/span>You have an iSCSI host that is unable to connect to an SVM named svm1 over a LIF name lif1. <br \/>\r<br>The home node and port of lif1 is port e0e. <br \/>\r<br>The event log show command displays the error iSCSI: <br \/>\r<br>network interface disabled for use; incoming connection discarded. <br \/>\r<br>Which command would you use to resolve the problem?<\/div><input type='hidden' name='question_id[]' id='qID_7' value='9028' \/><input type='hidden' id='answerType9028' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9028[]' id='answer-id-37410' class='answer   answerof-9028 ' value='37410'   \/><label for='answer-id-37410' id='answer-label-37410' class=' answer'><span>vserver iscsi create-target-alias svm1-status-admin up -vserver svm1<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9028[]' id='answer-id-37411' class='answer   answerof-9028 ' value='37411'   \/><label for='answer-id-37411' id='answer-label-37411' class=' answer'><span>broadcast-domain add-ports -broadcast-domain iscsi -ports cI01-01: e0e<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9028[]' id='answer-id-37412' class='answer   answerof-9028 ' value='37412'   \/><label for='answer-id-37412' id='answer-label-37412' class=' answer'><span>network interface modify -vserver svm1 -lif lif1 -failover-group Default<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9028[]' id='answer-id-37413' class='answer   answerof-9028 ' value='37413'   \/><label for='answer-id-37413' id='answer-label-37413' class=' answer'><span>iscsi interface enable -vserver svm1 -lif lif1<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-8' style=';'><div id='questionWrap-8'  class='   watupro-question-id-9029'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>8. <\/span>A new server has been installed in your environment, but it is unable to see its NetApp boot LUN. You have narrowed the problem down to the zoning on your Cisco switch which has the following configuration: <br \/>\r<br>zone name z_NetAppvsan 400 <br \/>\r<br>memberpwwn 20:00:00:25: B5: C0:ff:ee <br \/>\r<br>memberpwwn 50:0a:09:84:8d:7c:51: D5 <br \/>\r<br>zoneset name zs_NetAppvsan 400 <br \/>\r<br>memberz_NetApp <br \/>\r<br>zoneset activate name zs_NetAppvsan 400 <br \/>\r<br>What is the problem with your zoning configuration?<\/div><input type='hidden' name='question_id[]' id='qID_8' value='9029' \/><input type='hidden' id='answerType9029' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9029[]' id='answer-id-37414' class='answer   answerof-9029 ' value='37414'   \/><label for='answer-id-37414' id='answer-label-37414' class=' answer'><span>The member does not reference the VSA<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9029[]' id='answer-id-37415' class='answer   answerof-9029 ' value='37415'   \/><label for='answer-id-37415' id='answer-label-37415' class=' answer'><span>The zone and zoneset names do not match.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9029[]' id='answer-id-37416' class='answer   answerof-9029 ' value='37416'   \/><label for='answer-id-37416' id='answer-label-37416' class=' answer'><span>The zoneset was improperly activated.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9029[]' id='answer-id-37417' class='answer   answerof-9029 ' value='37417'   \/><label for='answer-id-37417' id='answer-label-37417' class=' answer'><span>The PWWN for your NetApp LIF is incorrect.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-9' style=';'><div id='questionWrap-9'  class='   watupro-question-id-9030'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>9. <\/span>A LUN copy has been created by using the lun copy command. <br \/>\r<br>To allow the copy to be seen on the same host, what would you do?<\/div><input type='hidden' name='question_id[]' id='qID_9' value='9030' \/><input type='hidden' id='answerType9030' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9030[]' id='answer-id-37418' class='answer   answerof-9030 ' value='37418'   \/><label for='answer-id-37418' id='answer-label-37418' class=' answer'><span>Create a new portset.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9030[]' id='answer-id-37419' class='answer   answerof-9030 ' value='37419'   \/><label for='answer-id-37419' id='answer-label-37419' class=' answer'><span>Map the LUN to the same igroup.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9030[]' id='answer-id-37420' class='answer   answerof-9030 ' value='37420'   \/><label for='answer-id-37420' id='answer-label-37420' class=' answer'><span>Change the serial number of the copied LU<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9030[]' id='answer-id-37421' class='answer   answerof-9030 ' value='37421'   \/><label for='answer-id-37421' id='answer-label-37421' class=' answer'><span>Configure SLM on the new node.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-10' style=';'><div id='questionWrap-10'  class='   watupro-question-id-9031'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>10. <\/span>You have an AFF A300 system that serves FC LUNs. The LUNs are replicated to a disaster recovery site that has a FAS8200 system that is running SATA drives. There are no FC or FCoE capable switches at the disaster recovery site. <br \/>\r<br>In this scenario, which three actions are required to test the disaster recovery LUNs on the Ethernet switches? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_10' value='9031' \/><input type='hidden' id='answerType9031' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9031[]' id='answer-id-37422' class='answer   answerof-9031 ' value='37422'   \/><label for='answer-id-37422' id='answer-label-37422' class=' answer'><span>License FC<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9031[]' id='answer-id-37423' class='answer   answerof-9031 ' value='37423'   \/><label for='answer-id-37423' id='answer-label-37423' class=' answer'><span>Create LIFs<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9031[]' id='answer-id-37424' class='answer   answerof-9031 ' value='37424'   \/><label for='answer-id-37424' id='answer-label-37424' class=' answer'><span>Map the LUNs to initiator groups<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9031[]' id='answer-id-37425' class='answer   answerof-9031 ' value='37425'   \/><label for='answer-id-37425' id='answer-label-37425' class=' answer'><span>Enable ISCSI<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9031[]' id='answer-id-37426' class='answer   answerof-9031 ' value='37426'   \/><label for='answer-id-37426' id='answer-label-37426' class=' answer'><span>Bind the initiator groups to port sets.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-11' style=';'><div id='questionWrap-11'  class='   watupro-question-id-9032'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>11. <\/span>You are creating a point-to-point connection over an ISL on a Cisco switch. <br \/>\r<br>Which port-channel type should you use?<\/div><input type='hidden' name='question_id[]' id='qID_11' value='9032' \/><input type='hidden' id='answerType9032' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9032[]' id='answer-id-37427' class='answer   answerof-9032 ' value='37427'   \/><label for='answer-id-37427' id='answer-label-37427' class=' answer'><span>NP<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9032[]' id='answer-id-37428' class='answer   answerof-9032 ' value='37428'   \/><label for='answer-id-37428' id='answer-label-37428' class=' answer'><span>F<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9032[]' id='answer-id-37429' class='answer   answerof-9032 ' value='37429'   \/><label for='answer-id-37429' id='answer-label-37429' class=' answer'><span>E<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9032[]' id='answer-id-37430' class='answer   answerof-9032 ' value='37430'   \/><label for='answer-id-37430' id='answer-label-37430' class=' answer'><span>TF<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-12' style=';'><div id='questionWrap-12'  class='   watupro-question-id-9033'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>12. <\/span>You want to verify that a host will be able to see the storage. A LUN is mapped to an igroup for the host, and both the host and storage are connected to FC switches. <br \/>\r<br>Which command will provide the path status information from the switch?<\/div><input type='hidden' name='question_id[]' id='qID_12' value='9033' \/><input type='hidden' id='answerType9033' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9033[]' id='answer-id-37431' class='answer   answerof-9033 ' value='37431'   \/><label for='answer-id-37431' id='answer-label-37431' class=' answer'><span>configure<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9033[]' id='answer-id-37432' class='answer   answerof-9033 ' value='37432'   \/><label for='answer-id-37432' id='answer-label-37432' class=' answer'><span>cfgshow<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9033[]' id='answer-id-37433' class='answer   answerof-9033 ' value='37433'   \/><label for='answer-id-37433' id='answer-label-37433' class=' answer'><span>fcping<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9033[]' id='answer-id-37434' class='answer   answerof-9033 ' value='37434'   \/><label for='answer-id-37434' id='answer-label-37434' class=' answer'><span>zoneshow<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-13' style=';'><div id='questionWrap-13'  class='   watupro-question-id-9034'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>13. <\/span>You want to verify back-end SAS cabling on a FAS9000 and SAN host connectivity from windows server 2016, WMware ESX 6.0, and Linux 2.6. <br \/>\r<br>Which two tools would you use to accomplish this task? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_13' value='9034' \/><input type='hidden' id='answerType9034' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9034[]' id='answer-id-37435' class='answer   answerof-9034 ' value='37435'   \/><label for='answer-id-37435' id='answer-label-37435' class=' answer'><span>Interoperability Matrix Tool<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9034[]' id='answer-id-37436' class='answer   answerof-9034 ' value='37436'   \/><label for='answer-id-37436' id='answer-label-37436' class=' answer'><span>Hardware Universe<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9034[]' id='answer-id-37437' class='answer   answerof-9034 ' value='37437'   \/><label for='answer-id-37437' id='answer-label-37437' class=' answer'><span>Config Advisor<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9034[]' id='answer-id-37438' class='answer   answerof-9034 ' value='37438'   \/><label for='answer-id-37438' id='answer-label-37438' class=' answer'><span>nSanity<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-14' style=';'><div id='questionWrap-14'  class='   watupro-question-id-9035'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>14. <\/span>Which three components must be verified in the IMT to ensure a support FC configuration? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_14' value='9035' \/><input type='hidden' id='answerType9035' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9035[]' id='answer-id-37439' class='answer   answerof-9035 ' value='37439'   \/><label for='answer-id-37439' id='answer-label-37439' class=' answer'><span>The FC HBA that is installed in the host<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9035[]' id='answer-id-37440' class='answer   answerof-9035 ' value='37440'   \/><label for='answer-id-37440' id='answer-label-37440' class=' answer'><span>The OS patch level or service pack<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9035[]' id='answer-id-37441' class='answer   answerof-9035 ' value='37441'   \/><label for='answer-id-37441' id='answer-label-37441' class=' answer'><span>The volume manager that is being used on the host<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9035[]' id='answer-id-37442' class='answer   answerof-9035 ' value='37442'   \/><label for='answer-id-37442' id='answer-label-37442' class=' answer'><span>The size and quantity of the internal disks<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9035[]' id='answer-id-37443' class='answer   answerof-9035 ' value='37443'   \/><label for='answer-id-37443' id='answer-label-37443' class=' answer'><span>The amount of memory that is installed in the host<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-15' style=';'><div id='questionWrap-15'  class='   watupro-question-id-9036'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>15. <\/span>Referring to port 3 in the exhibit, which two statements are correct? (Choose two.) <br \/>\r<br><br><img decoding=\"async\" width=607 height=322 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/NS0-507%20V8.files\/image004.jpg\" v:shapes=\"_x0000_i1027\"><br><\/div><input type='hidden' name='question_id[]' id='qID_15' value='9036' \/><input type='hidden' id='answerType9036' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9036[]' id='answer-id-37444' class='answer   answerof-9036 ' value='37444'   \/><label for='answer-id-37444' id='answer-label-37444' class=' answer'><span>Port 3 shows two LIFs connected.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9036[]' id='answer-id-37445' class='answer   answerof-9036 ' value='37445'   \/><label for='answer-id-37445' id='answer-label-37445' class=' answer'><span>The speed is hard coded to 16G<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9036[]' id='answer-id-37446' class='answer   answerof-9036 ' value='37446'   \/><label for='answer-id-37446' id='answer-label-37446' class=' answer'><span>Port 3 shows one LIF connected.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9036[]' id='answer-id-37447' class='answer   answerof-9036 ' value='37447'   \/><label for='answer-id-37447' id='answer-label-37447' class=' answer'><span>The speed is set to auto and negotiated to 16G<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-16' style=';'><div id='questionWrap-16'  class='   watupro-question-id-9037'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>16. <\/span>A company has Snapmirror configured between two ONTAP clusters. They want to add nodes to one of the clusters at a minimum, which LIF would be required to be defined on the new nodes?<\/div><input type='hidden' name='question_id[]' id='qID_16' value='9037' \/><input type='hidden' id='answerType9037' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9037[]' id='answer-id-37448' class='answer   answerof-9037 ' value='37448'   \/><label for='answer-id-37448' id='answer-label-37448' class=' answer'><span>Node-management, data, and intercluster<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9037[]' id='answer-id-37449' class='answer   answerof-9037 ' value='37449'   \/><label for='answer-id-37449' id='answer-label-37449' class=' answer'><span>Node-management and intercluster<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9037[]' id='answer-id-37450' class='answer   answerof-9037 ' value='37450'   \/><label for='answer-id-37450' id='answer-label-37450' class=' answer'><span>Data, node-management, and FC<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9037[]' id='answer-id-37451' class='answer   answerof-9037 ' value='37451'   \/><label for='answer-id-37451' id='answer-label-37451' class=' answer'><span>Node-management<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-17' style=';'><div id='questionWrap-17'  class='   watupro-question-id-9038'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>17. <\/span>You want to configure iSCSI on a 4-node cluster that only has NFS configured. You need to guarantee that you have at least two optimized paths per LUN. <br \/>\r<br>In this scenario, what are the minimum number of iSCSI LIF needed?<\/div><input type='hidden' name='question_id[]' id='qID_17' value='9038' \/><input type='hidden' id='answerType9038' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9038[]' id='answer-id-37452' class='answer   answerof-9038 ' value='37452'   \/><label for='answer-id-37452' id='answer-label-37452' class=' answer'><span>6<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9038[]' id='answer-id-37453' class='answer   answerof-9038 ' value='37453'   \/><label for='answer-id-37453' id='answer-label-37453' class=' answer'><span>4<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9038[]' id='answer-id-37454' class='answer   answerof-9038 ' value='37454'   \/><label for='answer-id-37454' id='answer-label-37454' class=' answer'><span>8<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9038[]' id='answer-id-37455' class='answer   answerof-9038 ' value='37455'   \/><label for='answer-id-37455' id='answer-label-37455' class=' answer'><span>2<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-18' style=';'><div id='questionWrap-18'  class='   watupro-question-id-9039'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>18. <\/span>When implementing ONTAP SAN for VMware, in which three would VSC help? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_18' value='9039' \/><input type='hidden' id='answerType9039' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9039[]' id='answer-id-37456' class='answer   answerof-9039 ' value='37456'   \/><label for='answer-id-37456' id='answer-label-37456' class=' answer'><span>When provisioning the lun<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9039[]' id='answer-id-37457' class='answer   answerof-9039 ' value='37457'   \/><label for='answer-id-37457' id='answer-label-37457' class=' answer'><span>When updating HBA driverQ`1a<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9039[]' id='answer-id-37458' class='answer   answerof-9039 ' value='37458'   \/><label for='answer-id-37458' id='answer-label-37458' class=' answer'><span>When configuring host best practices<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9039[]' id='answer-id-37459' class='answer   answerof-9039 ' value='37459'   \/><label for='answer-id-37459' id='answer-label-37459' class=' answer'><span>When provisioning the datastore<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9039[]' id='answer-id-37460' class='answer   answerof-9039 ' value='37460'   \/><label for='answer-id-37460' id='answer-label-37460' class=' answer'><span>When creating FC switch zoning<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-19' style=';'><div id='questionWrap-19'  class='   watupro-question-id-9040'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>19. <\/span>What are three considerations when creating a physical reference diagram of an FC SAN? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_19' value='9040' \/><input type='hidden' id='answerType9040' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9040[]' id='answer-id-37461' class='answer   answerof-9040 ' value='37461'   \/><label for='answer-id-37461' id='answer-label-37461' class=' answer'><span>Hardware is compatible<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9040[]' id='answer-id-37462' class='answer   answerof-9040 ' value='37462'   \/><label for='answer-id-37462' id='answer-label-37462' class=' answer'><span>FC SAN zoning is available<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9040[]' id='answer-id-37463' class='answer   answerof-9040 ' value='37463'   \/><label for='answer-id-37463' id='answer-label-37463' class=' answer'><span>Power connectivity is available<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9040[]' id='answer-id-37464' class='answer   answerof-9040 ' value='37464'   \/><label for='answer-id-37464' id='answer-label-37464' class=' answer'><span>FC port connectivity is available<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-9040[]' id='answer-id-37465' class='answer   answerof-9040 ' value='37465'   \/><label for='answer-id-37465' id='answer-label-37465' class=' answer'><span>FC switches are available<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-20' style=';'><div id='questionWrap-20'  class='   watupro-question-id-9041'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>20. <\/span>You are planning a migration from a 7-mode system running DATA ONTAP 8.0 to a new AFF A700 ONTAP 9.1 system. This 7-mode system provides only iSCSI LUNs for a windows server 2012R2 server farm. There is no FC fabric available for this migration. <br \/>\r<br>In this scenario, what would you use for the migration?<\/div><input type='hidden' name='question_id[]' id='qID_20' value='9041' \/><input type='hidden' id='answerType9041' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9041[]' id='answer-id-37466' class='answer   answerof-9041 ' value='37466'   \/><label for='answer-id-37466' id='answer-label-37466' class=' answer'><span>Foreign LUN import (FLI)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9041[]' id='answer-id-37467' class='answer   answerof-9041 ' value='37467'   \/><label for='answer-id-37467' id='answer-label-37467' class=' answer'><span>Unified Host Utility Kit<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9041[]' id='answer-id-37468' class='answer   answerof-9041 ' value='37468'   \/><label for='answer-id-37468' id='answer-label-37468' class=' answer'><span>7-mode Transition tool (7MTT)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-9041[]' id='answer-id-37469' class='answer   answerof-9041 ' value='37469'   \/><label for='answer-id-37469' id='answer-label-37469' class=' answer'><span>OnCommand System Manager<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div style='display:none' id='question-21'>\n\t<div class='question-content'>\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\" alt=\"Loading...\" title=\"Loading...\" \/>&nbsp;Loading...\t<\/div>\n<\/div>\n\n<br \/>\n\t\n\t\t\t<div class=\"watupro_buttons flex \" id=\"watuPROButtons468\" >\n\t\t  <div id=\"prev-question\" style=\"display:none;\"><input type=\"button\" value=\"&lt; Previous\" onclick=\"WatuPRO.nextQuestion(event, 'previous');\"\/><\/div>\t\t  \t\t  \t\t   \n\t\t   \t  \t\t<div><input type=\"button\" name=\"action\" class=\"watupro-submit-button\" onclick=\"WatuPRO.submitResult(event)\" id=\"action-button\" value=\"View Results\"  \/>\n\t\t<\/div>\n\t\t<\/div>\n\t\t\n\t<input type=\"hidden\" name=\"quiz_id\" value=\"468\" id=\"watuPROExamID\"\/>\n\t<input type=\"hidden\" name=\"start_time\" id=\"startTime\" value=\"2026-05-03 13:54:29\" \/>\n\t<input type=\"hidden\" name=\"start_timestamp\" id=\"startTimeStamp\" value=\"1777816469\" \/>\n\t<input type=\"hidden\" name=\"question_ids\" value=\"\" \/>\n\t<input type=\"hidden\" name=\"watupro_questions\" value=\"9022:37384,37385,37386,37387 | 9023:37388,37389,37390,37391,37392 | 9024:37393,37394,37395,37396,37397 | 9025:37398,37399,37400,37401 | 9026:37402,37403,37404,37405 | 9027:37406,37407,37408,37409 | 9028:37410,37411,37412,37413 | 9029:37414,37415,37416,37417 | 9030:37418,37419,37420,37421 | 9031:37422,37423,37424,37425,37426 | 9032:37427,37428,37429,37430 | 9033:37431,37432,37433,37434 | 9034:37435,37436,37437,37438 | 9035:37439,37440,37441,37442,37443 | 9036:37444,37445,37446,37447 | 9037:37448,37449,37450,37451 | 9038:37452,37453,37454,37455 | 9039:37456,37457,37458,37459,37460 | 9040:37461,37462,37463,37464,37465 | 9041:37466,37467,37468,37469\" \/>\n\t<input type=\"hidden\" name=\"no_ajax\" value=\"0\">\t\t\t<\/form>\n\t<p>&nbsp;<\/p>\n<\/div>\n\n<script type=\"text\/javascript\">\n\/\/jQuery(document).ready(function(){\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \t\nvar question_ids = \"9022,9023,9024,9025,9026,9027,9028,9029,9030,9031,9032,9033,9034,9035,9036,9037,9038,9039,9040,9041\";\nWatuPROSettings[468] = {};\nWatuPRO.qArr = question_ids.split(',');\nWatuPRO.exam_id = 468;\t    \nWatuPRO.post_id = 788;\nWatuPRO.store_progress = 0;\nWatuPRO.curCatPage = 1;\nWatuPRO.requiredIDs=\"0\".split(\",\");\nWatuPRO.hAppID = \"0.96015000 1777816469\";\nvar url = \"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/show_exam.php\";\nWatuPRO.examMode = 1;\nWatuPRO.siteURL=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-admin\/admin-ajax.php\";\nWatuPRO.emailIsNotRequired = 0;\nWatuPROIntel.init(468);\nWatuPRO.inCategoryPages=1;});    \t \n<\/script>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Have you passed your NS0-507 exam test? The main difference between NS0-506 and NS0-507 is that NS0-506 focused on clustered Data ONTAP and NS0-507 focuses on ONTAP 9. There is no good way for you to prepare for your NS0-507 Network Appliance NCIE-SAN certification exam. Go to your NS0-507 exam questions now. Test begin now! [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[127,148],"tags":[2239,2234,2237,2240,2235,2236,2238],"class_list":["post-788","post","type-post","status-publish","format-standard","hentry","category-network-appliance","category-network-appliance-ncie-san","tag-network-appliance-ncie-san-ns0-507-practice-exam","tag-ns0-507","tag-ns0-507-exam-dumps","tag-ns0-507-exam-test","tag-ns0-507-free-exam","tag-ns0-507-free-questions","tag-ns0-507-real-questions"],"_links":{"self":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/788","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/comments?post=788"}],"version-history":[{"count":1,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/788\/revisions"}],"predecessor-version":[{"id":789,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/788\/revisions\/789"}],"wp:attachment":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/media?parent=788"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/categories?post=788"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/tags?post=788"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}