{"id":3412,"date":"2019-04-17T08:49:46","date_gmt":"2019-04-17T08:49:46","guid":{"rendered":"https:\/\/www.dumpsbase.com\/freedumps\/?p=3412"},"modified":"2019-04-17T08:49:48","modified_gmt":"2019-04-17T08:49:48","slug":"real-dee-1721-dell-emc-sc-series-expert-exam-dumps","status":"publish","type":"post","link":"https:\/\/www.dumpsbase.com\/freedumps\/real-dee-1721-dell-emc-sc-series-expert-exam-dumps.html","title":{"rendered":"Real DEE-1721 Dell EMC SC Series Expert Exam Dumps"},"content":{"rendered":"\n<p>DEE-1721 exam is the expert level of Dell EMC SC Series certification, which focuses on the knowledge and activities involved in installing, initializing, configuring, testing, updating, upgrading and troubleshoot the hardware and software of the Dell EMC SC Series Storage products. Real DEE-1721 Dell EMC SC Series Expert exam dumps are online to help you pass your Expert \u2013 Implementation Engineer, SC Series Exam in the first try.<\/p>\n\n\n\n<p class=\"has-text-color has-medium-font-size has-vivid-red-color\"><strong><em>Demo of Real DEE-1721 Dell EMC SC Series Expert Exam Dumps<\/em><\/strong><\/p>\n\n\n\n<script>\n\t  window.fbAsyncInit = function() {\n\t    FB.init({\n\t      appId            : '622169541470367',\n\t      autoLogAppEvents : true,\n\t      xfbml            : true,\n\t      version          : 'v3.1'\n\t    });\n\t  };\n\t\n\t  (function(d, s, id){\n\t     var js, fjs = d.getElementsByTagName(s)[0];\n\t     if (d.getElementById(id)) {return;}\n\t     js = d.createElement(s); js.id = id;\n\t     js.src = \"https:\/\/connect.facebook.net\/en_US\/sdk.js\";\n\t     fjs.parentNode.insertBefore(js, fjs);\n\t   }(document, 'script', 'facebook-jssdk'));\n\t<\/script><script type=\"text\/javascript\" >\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \nif(!window.jQuery) alert(\"The important jQuery library is not properly loaded in your site. Your WordPress theme is probably missing the essential wp_head() call. You can switch to another theme and you will see that the plugin works fine and this notice disappears. If you are still not sure what to do you can contact us for help.\");\n});\n<\/script>  \n  \n<div  id=\"watupro_quiz\" class=\"quiz-area single-page-quiz\">\n<p id=\"submittingExam919\" style=\"display:none;text-align:center;\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\"><\/p>\n\n<div class=\"watupro-exam-description\" id=\"description-quiz-919\"><\/div>\n\n<form action=\"\" method=\"post\" class=\"quiz-form\" id=\"quiz-919\"  enctype=\"multipart\/form-data\" >\n<div class='watu-question ' id='question-1' style=';'><div id='questionWrap-1'  class='   watupro-question-id-27220'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>1. <\/span>Several servers connected to the Storage Center through FC fabrics using WWN zoning. You recently replaced a server\u2019s FC HBA; however, the server no longer connects to the Storage Center. <br \/>\r<br>What is causing this issue?<\/div><input type='hidden' name='question_id[]' id='qID_1' value='27220' \/><input type='hidden' id='answerType27220' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27220[]' id='answer-id-112273' class='answer   answerof-27220 ' value='112273'   \/><label for='answer-id-112273' id='answer-label-112273' class=' answer'><span>Storage Cento fault domains must be updated with the new HBA WWN<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27220[]' id='answer-id-112274' class='answer   answerof-27220 ' value='112274'   \/><label for='answer-id-112274' id='answer-label-112274' class=' answer'><span>Storage Center fault domains must be converted to Virtual Pat Node<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27220[]' id='answer-id-112275' class='answer   answerof-27220 ' value='112275'   \/><label for='answer-id-112275' id='answer-label-112275' class=' answer'><span>Server's zone must be updated with the new switch port to which the HBA is connected<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27220[]' id='answer-id-112276' class='answer   answerof-27220 ' value='112276'   \/><label for='answer-id-112276' id='answer-label-112276' class=' answer'><span>Server's zone must be updated with the new NBA WWN<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-2' style=';'><div id='questionWrap-2'  class='   watupro-question-id-27221'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>2. <\/span>A storage administrator has multiple servers connected to the Storage Center through two iSCSI networks. You use a software iSCSI Initiator on the servers and the Storage Center runs in Virtual Port Mode. <br \/>\r<br>Which IP address is required in the iSCSI Initiator for proper connectivity?<\/div><input type='hidden' name='question_id[]' id='qID_2' value='27221' \/><input type='hidden' id='answerType27221' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27221[]' id='answer-id-112277' class='answer   answerof-27221 ' value='112277'   \/><label for='answer-id-112277' id='answer-label-112277' class=' answer'><span>Primary IP address for each domain<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27221[]' id='answer-id-112278' class='answer   answerof-27221 ' value='112278'   \/><label for='answer-id-112278' id='answer-label-112278' class=' answer'><span>Control Port IP address for each domain<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27221[]' id='answer-id-112279' class='answer   answerof-27221 ' value='112279'   \/><label for='answer-id-112279' id='answer-label-112279' class=' answer'><span>Reserve IP address for each domain<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27221[]' id='answer-id-112280' class='answer   answerof-27221 ' value='112280'   \/><label for='answer-id-112280' id='answer-label-112280' class=' answer'><span>Management IP address of each controller<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-3' style=';'><div id='questionWrap-3'  class='   watupro-question-id-27222'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>3. <\/span>Which processes should be used when testing controller failover on a newly installed Storage Center?<\/div><input type='hidden' name='question_id[]' id='qID_3' value='27222' \/><input type='hidden' id='answerType27222' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27222[]' id='answer-id-112281' class='answer   answerof-27222 ' value='112281'   \/><label for='answer-id-112281' id='answer-label-112281' class=' answer'><span>Start server IO to a volume, restart a controller, then rebalance ports and ensure no IO errors.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27222[]' id='answer-id-112282' class='answer   answerof-27222 ' value='112282'   \/><label for='answer-id-112282' id='answer-label-112282' class=' answer'><span>Start server IO to a volume, restart either controller, and ensure no IO errors are reported.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27222[]' id='answer-id-112283' class='answer   answerof-27222 ' value='112283'   \/><label for='answer-id-112283' id='answer-label-112283' class=' answer'><span>Start server IO to volumes owned on each controller, restart the controllers sequentially, and ensure no IO error.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27222[]' id='answer-id-112284' class='answer   answerof-27222 ' value='112284'   \/><label for='answer-id-112284' id='answer-label-112284' class=' answer'><span>Start server IO to volumes owned on each controller, restart the controllers simutaneously. and ensure no IO error.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-4' style=';'><div id='questionWrap-4'  class='   watupro-question-id-27223'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>4. <\/span>Exhibit: <br \/>\r<br>You are troubleshooting disk connectivity issues on an SC9000. The SC9000 has two SC220 enclosures on one chain and two SC280 enclosures on the other chain. You verify the physical cabling and discover the array is cabled as shown in the exhibit. <br \/>\r<br><br><img decoding=\"async\" width=624 height=444 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image003.jpg\" v:shapes=\"Picture_x0020_4\"><br><br \/>\r<br>What identities the issue with how the environment is cabled?<\/div><input type='hidden' name='question_id[]' id='qID_4' value='27223' \/><input type='hidden' id='answerType27223' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27223[]' id='answer-id-112285' class='answer   answerof-27223 ' value='112285'   \/><label for='answer-id-112285' id='answer-label-112285' class=' answer'><span>Chain containing the SC220 storage enclosures is cabled incorrectly<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27223[]' id='answer-id-112286' class='answer   answerof-27223 ' value='112286'   \/><label for='answer-id-112286' id='answer-label-112286' class=' answer'><span>Chain containing the SC220 storage enclosures must be divided into two separate chains<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27223[]' id='answer-id-112287' class='answer   answerof-27223 ' value='112287'   \/><label for='answer-id-112287' id='answer-label-112287' class=' answer'><span>Chain containing the SC220 storage enclosures is cabled incorrectly<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27223[]' id='answer-id-112288' class='answer   answerof-27223 ' value='112288'   \/><label for='answer-id-112288' id='answer-label-112288' class=' answer'><span>Chain containing the SC280 storage enclosures must be divided into two separate chains<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-5' style=';'><div id='questionWrap-5'  class='   watupro-question-id-27224'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>5. <\/span>After setting up an SC4020 and turning on the system, both controllers initialize to Safe Mode and are ready for configuration You plug the serial cable into the first controller and type the platform prejoin show command You then receive the command output shown in the exhibit <br \/>\r<br><br><img decoding=\"async\" width=587 height=510 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image005.jpg\" v:shapes=\"Picture_x0020_7\"><br><br \/>\r<br>If you continued configuring the controller, what are the reasons why the deployment will fair?<\/div><input type='hidden' name='question_id[]' id='qID_5' value='27224' \/><input type='hidden' id='answerType27224' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27224[]' id='answer-id-112289' class='answer   answerof-27224 ' value='112289'   \/><label for='answer-id-112289' id='answer-label-112289' class=' answer'><span>Serial cable needs to be plugged into the top controller Controller chassis is installed upside down in the rack<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27224[]' id='answer-id-112290' class='answer   answerof-27224 ' value='112290'   \/><label for='answer-id-112290' id='answer-label-112290' class=' answer'><span>Serial cable needs to be plugged into the top controller eth1 IPv4 IP address used at the factory to load the firmware was not cleared before shipping<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27224[]' id='answer-id-112291' class='answer   answerof-27224 ' value='112291'   \/><label for='answer-id-112291' id='answer-label-112291' class=' answer'><span>Serial cable needs to be plugged into the bottom controller eth1 IPv4 IP address used at the factory to load the firmware was not cleared before shipping<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27224[]' id='answer-id-112292' class='answer   answerof-27224 ' value='112292'   \/><label for='answer-id-112292' id='answer-label-112292' class=' answer'><span>Serial cable needs to be plugged into the bottom controller Controller chassis is installed upside down in the rack<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-6' style=';'><div id='questionWrap-6'  class='   watupro-question-id-27225'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>6. <\/span>You added an existing Storage Center to an instance of Dell Storage Manager using the Volume Manger user. You are able to map volumes in the 10K folder to the servers but not the volumes in the SSD folder. <br \/>\r<br>What is the reason for this issue?<\/div><input type='hidden' name='question_id[]' id='qID_6' value='27225' \/><input type='hidden' id='answerType27225' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27225[]' id='answer-id-112293' class='answer   answerof-27225 ' value='112293'   \/><label for='answer-id-112293' id='answer-label-112293' class=' answer'><span>Only the Administrator user can map volumes in the SSD folder.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27225[]' id='answer-id-112294' class='answer   answerof-27225 ' value='112294'   \/><label for='answer-id-112294' id='answer-label-112294' class=' answer'><span>Volume Manager user can only access one disk folder<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27225[]' id='answer-id-112295' class='answer   answerof-27225 ' value='112295'   \/><label for='answer-id-112295' id='answer-label-112295' class=' answer'><span>Volume Manager user is a member of a group that is restricted from the SSD folder<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27225[]' id='answer-id-112296' class='answer   answerof-27225 ' value='112296'   \/><label for='answer-id-112296' id='answer-label-112296' class=' answer'><span>Servers cannot detect SSD drives<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-7' style=';'><div id='questionWrap-7'  class='   watupro-question-id-27226'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>7. <\/span>You have added two SC420 storage enclosures to an existing SC9000 storage array on a new chain. All new disks are being added to a new disk folder. The disks being installed consist of six SSDs, six 15K, twelve 10K, and twenty-four 7.2K. <br \/>\r<br>What is the default layout of the tiers within the disk folder? <br \/>\r<br>A) <br \/>\r<br><br><img decoding=\"async\" width=269 height=63 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image007.jpg\" v:shapes=\"Picture_x0020_10\"><br><br \/>\r<br>B) <br \/>\r<br><br><img decoding=\"async\" width=265 height=58 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image009.jpg\" v:shapes=\"Picture_x0020_13\"><br><br \/>\r<br>C) <br \/>\r<br><br><img decoding=\"async\" width=240 height=63 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image011.jpg\" v:shapes=\"Picture_x0020_16\"><br><br \/>\r<br>D) <br \/>\r<br><br><img decoding=\"async\" width=227 height=66 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image013.jpg\" v:shapes=\"Picture_x0020_19\"><br><\/div><input type='hidden' name='question_id[]' id='qID_7' value='27226' \/><input type='hidden' id='answerType27226' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27226[]' id='answer-id-112297' class='answer   answerof-27226 ' value='112297'   \/><label for='answer-id-112297' id='answer-label-112297' class=' answer'><span>Option A<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27226[]' id='answer-id-112298' class='answer   answerof-27226 ' value='112298'   \/><label for='answer-id-112298' id='answer-label-112298' class=' answer'><span>Option B<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27226[]' id='answer-id-112299' class='answer   answerof-27226 ' value='112299'   \/><label for='answer-id-112299' id='answer-label-112299' class=' answer'><span>Option C<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27226[]' id='answer-id-112300' class='answer   answerof-27226 ' value='112300'   \/><label for='answer-id-112300' id='answer-label-112300' class=' answer'><span>Option D<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-8' style=';'><div id='questionWrap-8'  class='   watupro-question-id-27227'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>8. <\/span>After configuring a new SC4020, you receive an alert that all disks are only seen on one path. <br \/>\r<br>What are the reasons for the alert?<\/div><input type='hidden' name='question_id[]' id='qID_8' value='27227' \/><input type='hidden' id='answerType27227' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27227[]' id='answer-id-112301' class='answer   answerof-27227 ' value='112301'   \/><label for='answer-id-112301' id='answer-label-112301' class=' answer'><span>Both SAS cables are defective and the alert definition was configured incorrectly.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27227[]' id='answer-id-112302' class='answer   answerof-27227 ' value='112302'   \/><label for='answer-id-112302' id='answer-label-112302' class=' answer'><span>One SAS cable was not connected between the controllers and the alert definition was configured incorrectly.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27227[]' id='answer-id-112303' class='answer   answerof-27227 ' value='112303'   \/><label for='answer-id-112303' id='answer-label-112303' class=' answer'><span>One SAS cable was not connected between the controllers and one SAS cable is defective<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27227[]' id='answer-id-112304' class='answer   answerof-27227 ' value='112304'   \/><label for='answer-id-112304' id='answer-label-112304' class=' answer'><span>One SAS cable is defective and the other path to the disks was not managed<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-9' style=';'><div id='questionWrap-9'  class='   watupro-question-id-27228'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>9. <\/span>You are performing failover testing on an FC-attached dual controller SC8000 storage array. You notice that the storage administrator\u2019s Microsoft Windows 2008 R2 servers experience I\/O errors. <br \/>\r<br>However, the RHEL and ESX servers are not experiencing any problems. All FC HBA time outs are configured based on Dell EMC best practices. <br \/>\r<br>In addition, the Windows servers that are experiencing issues have had no OS-level configuration changes related to SAN storage. All servers use the same FC fabric. <br \/>\r<br>What is causing the connectivity loss during failover?<\/div><input type='hidden' name='question_id[]' id='qID_9' value='27228' \/><input type='hidden' id='answerType27228' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27228[]' id='answer-id-112305' class='answer   answerof-27228 ' value='112305'   \/><label for='answer-id-112305' id='answer-label-112305' class=' answer'><span>NPIV is not enabled on the Storage Center FC local ports<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27228[]' id='answer-id-112306' class='answer   answerof-27228 ' value='112306'   \/><label for='answer-id-112306' id='answer-label-112306' class=' answer'><span>FC cables plugged into the Windows servers have RX and TX reversed<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27228[]' id='answer-id-112307' class='answer   answerof-27228 ' value='112307'   \/><label for='answer-id-112307' id='answer-label-112307' class=' answer'><span>Windows disk timeout value is set incorrectly<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27228[]' id='answer-id-112308' class='answer   answerof-27228 ' value='112308'   \/><label for='answer-id-112308' id='answer-label-112308' class=' answer'><span>Incorrect OS type was selected when the Windows server objects were created<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-10' style=';'><div id='questionWrap-10'  class='   watupro-question-id-27229'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>10. <\/span>A dual controller SC Series using iSCSI needs to be installed. The site will use two switches\/VLANs and run in Virtual Port mode. <br \/>\r<br>Which exhibit represents the correct iSCSI cabling? <br \/>\r<br>A) <br \/>\r<br><br><img decoding=\"async\" width=595 height=205 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image015.jpg\" v:shapes=\"Picture_x0020_22\"><br><br \/>\r<br>B) <br \/>\r<br><br><img decoding=\"async\" width=477 height=169 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image017.jpg\" v:shapes=\"Picture_x0020_25\"><br><br \/>\r<br>C) <br \/>\r<br><br><img decoding=\"async\" width=504 height=170 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image019.jpg\" v:shapes=\"Picture_x0020_28\"><br><br \/>\r<br>D) <br \/>\r<br><br><img decoding=\"async\" width=494 height=167 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image021.jpg\" v:shapes=\"Picture_x0020_31\"><br><\/div><input type='hidden' name='question_id[]' id='qID_10' value='27229' \/><input type='hidden' id='answerType27229' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27229[]' id='answer-id-112309' class='answer   answerof-27229 ' value='112309'   \/><label for='answer-id-112309' id='answer-label-112309' class=' answer'><span>Option A<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27229[]' id='answer-id-112310' class='answer   answerof-27229 ' value='112310'   \/><label for='answer-id-112310' id='answer-label-112310' class=' answer'><span>Option B<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27229[]' id='answer-id-112311' class='answer   answerof-27229 ' value='112311'   \/><label for='answer-id-112311' id='answer-label-112311' class=' answer'><span>Option C<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27229[]' id='answer-id-112312' class='answer   answerof-27229 ' value='112312'   \/><label for='answer-id-112312' id='answer-label-112312' class=' answer'><span>Option D<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-11' style=';'><div id='questionWrap-11'  class='   watupro-question-id-27230'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>11. <\/span>Refer to the Exhibit: <br \/>\r<br><br><img decoding=\"async\" width=624 height=395 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image023.jpg\" v:shapes=\"Picture_x0020_34\"><br><br \/>\r<br>If a user expires Replay 2, which page(s) is deleted?<\/div><input type='hidden' name='question_id[]' id='qID_11' value='27230' \/><input type='hidden' id='answerType27230' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27230[]' id='answer-id-112313' class='answer   answerof-27230 ' value='112313'   \/><label for='answer-id-112313' id='answer-label-112313' class=' answer'><span>A1 only<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27230[]' id='answer-id-112314' class='answer   answerof-27230 ' value='112314'   \/><label for='answer-id-112314' id='answer-label-112314' class=' answer'><span>A1 and C1<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27230[]' id='answer-id-112315' class='answer   answerof-27230 ' value='112315'   \/><label for='answer-id-112315' id='answer-label-112315' class=' answer'><span>B, D, and E<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27230[]' id='answer-id-112316' class='answer   answerof-27230 ' value='112316'   \/><label for='answer-id-112316' id='answer-label-112316' class=' answer'><span>C1 only<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-12' style=';'><div id='questionWrap-12'  class='   watupro-question-id-27231'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>12. <\/span>A storage administrator wants to perform an SCOS update to SCOS version 6.7.5. The SC Series is currently at SCOS version 6.5.30. The SC Series storage array is located at a secure facility and does not allow connectivity to any network outside the facility. <br \/>\r<br>The Administrator is attempting to use the Storage Center Update Utility to accomplish this task but has been unsuccessful. <br \/>\r<br>What is the reason for this Issue?<\/div><input type='hidden' name='question_id[]' id='qID_12' value='27231' \/><input type='hidden' id='answerType27231' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27231[]' id='answer-id-112317' class='answer   answerof-27231 ' value='112317'   \/><label for='answer-id-112317' id='answer-label-112317' class=' answer'><span>Storage Center has not passed pre-upgrade checks and is blocking the update<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27231[]' id='answer-id-112318' class='answer   answerof-27231 ' value='112318'   \/><label for='answer-id-112318' id='answer-label-112318' class=' answer'><span>Storage Center is not at the minimum required SCOS version to use the utility<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27231[]' id='answer-id-112319' class='answer   answerof-27231 ' value='112319'   \/><label for='answer-id-112319' id='answer-label-112319' class=' answer'><span>Storage Center is not licensed to use the Storage Center Updated Utility<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27231[]' id='answer-id-112320' class='answer   answerof-27231 ' value='112320'   \/><label for='answer-id-112320' id='answer-label-112320' class=' answer'><span>Secure facility is not allowing the administrator\u2019s laptop to connect to the Storage Center across the network.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-13' style=';'><div id='questionWrap-13'  class='   watupro-question-id-27232'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>13. <\/span>A site has multiple storage administrators. Some administrators need to be limited to manage only specific volumes. The administrator should be able to create and present volumes within the administrator's area. Those administrators should NOT be able to see any other volumes created in the Storage Center. <br \/>\r<br>How should the deployment engineer accomplish tins task?<\/div><input type='hidden' name='question_id[]' id='qID_13' value='27232' \/><input type='hidden' id='answerType27232' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27232[]' id='answer-id-112321' class='answer   answerof-27232 ' value='112321'   \/><label for='answer-id-112321' id='answer-label-112321' class=' answer'><span>Grant the administrator Volume Manager access. Create server folders and move the desired volumes into them, then assign the server folder to the desired administrator.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27232[]' id='answer-id-112322' class='answer   answerof-27232 ' value='112322'   \/><label for='answer-id-112322' id='answer-label-112322' class=' answer'><span>Grant the administrator Admin user access. Create server folders and move the desired volumes into them then assign the server folder to the desired administrator.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27232[]' id='answer-id-112323' class='answer   answerof-27232 ' value='112323'   \/><label for='answer-id-112323' id='answer-label-112323' class=' answer'><span>Grant the administrator Volume Manager access. Create volume folders and move the desired volumes into them, then assign the volume folder to the desired administrator.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27232[]' id='answer-id-112324' class='answer   answerof-27232 ' value='112324'   \/><label for='answer-id-112324' id='answer-label-112324' class=' answer'><span>Grant the administrator Admin user access. Create volume folders and move the desired volumes into them, then assign the volume folder to the desired administrator.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-14' style=';'><div id='questionWrap-14'  class='   watupro-question-id-27233'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>14. <\/span>A company has a four-node Microsoft Windows cluster that runs Microsoft SQL Server databases. Each server boots from its own Boot from SAN volume on the Storage Center. All servers need access to the database volumes. In addition, a server cluster objects has been created with the four servers assigned to it in Dell Storage Manager. <br \/>\r<br>How should the volumes be mapped to these servers using the server cluster?<\/div><input type='hidden' name='question_id[]' id='qID_14' value='27233' \/><input type='hidden' id='answerType27233' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27233[]' id='answer-id-112325' class='answer   answerof-27233 ' value='112325'   \/><label for='answer-id-112325' id='answer-label-112325' class=' answer'><span>Map the boot volume of each server individually \r\nMap all database volumes to the cluster\u2019s Leader node<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27233[]' id='answer-id-112326' class='answer   answerof-27233 ' value='112326'   \/><label for='answer-id-112326' id='answer-label-112326' class=' answer'><span>Map the boot volume of each server individually \r\nMap all database volumes to the server cluster<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27233[]' id='answer-id-112327' class='answer   answerof-27233 ' value='112327'   \/><label for='answer-id-112327' id='answer-label-112327' class=' answer'><span>Map all boot volumes to the server cluster \r\nMap all database volumes to each server individually<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27233[]' id='answer-id-112328' class='answer   answerof-27233 ' value='112328'   \/><label for='answer-id-112328' id='answer-label-112328' class=' answer'><span>Map all boot volumes to the server cluster \r\nMap all database volumes to the server cluster<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-15' style=';'><div id='questionWrap-15'  class='   watupro-question-id-27234'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>15. <\/span>You need to install a dual controller Storage Center with an SC200 enclosure and an SC280 enclosure. <br \/>\r<br>Which exhibit represents the correct back-end cabling? <br \/>\r<br>A) <br \/>\r<br><br><img decoding=\"async\" width=592 height=259 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image025.jpg\" v:shapes=\"Picture_x0020_49\"><br><br \/>\r<br>B) <br \/>\r<br><br><img decoding=\"async\" width=574 height=268 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image027.jpg\" v:shapes=\"Picture_x0020_52\"><br><br \/>\r<br>C) <br \/>\r<br><br><img decoding=\"async\" width=472 height=334 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image029.jpg\" v:shapes=\"Picture_x0020_58\"><br><br \/>\r<br>D) <br \/>\r<br><br><img decoding=\"async\" width=579 height=383 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image031.jpg\" v:shapes=\"Picture_x0020_55\"><br><\/div><input type='hidden' name='question_id[]' id='qID_15' value='27234' \/><input type='hidden' id='answerType27234' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27234[]' id='answer-id-112329' class='answer   answerof-27234 ' value='112329'   \/><label for='answer-id-112329' id='answer-label-112329' class=' answer'><span>Option A<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27234[]' id='answer-id-112330' class='answer   answerof-27234 ' value='112330'   \/><label for='answer-id-112330' id='answer-label-112330' class=' answer'><span>Option B<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27234[]' id='answer-id-112331' class='answer   answerof-27234 ' value='112331'   \/><label for='answer-id-112331' id='answer-label-112331' class=' answer'><span>Option C<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27234[]' id='answer-id-112332' class='answer   answerof-27234 ' value='112332'   \/><label for='answer-id-112332' id='answer-label-112332' class=' answer'><span>Option D<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-16' style=';'><div id='questionWrap-16'  class='   watupro-question-id-27235'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>16. <\/span>You are adding a 4-port FC card into the SC9000 storage array. Slots 4 C 6 are occupied and Slot 4 contains a half-height card. <br \/>\r<br>Which actions should occur to free up the full height slot and add the FC card? <br \/>\r<br>A) <br \/>\r<br><br><img decoding=\"async\" width=614 height=52 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image033.jpg\" v:shapes=\"Picture_x0020_61\"><br><br \/>\r<br>B) <br \/>\r<br><br><img decoding=\"async\" width=624 height=50 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image035.jpg\" v:shapes=\"Picture_x0020_64\"><br><br \/>\r<br>C) <br \/>\r<br><br><img decoding=\"async\" width=624 height=48 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image037.jpg\" v:shapes=\"Picture_x0020_67\"><br><br \/>\r<br>D) <br \/>\r<br><br><img decoding=\"async\" width=624 height=51 src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2018\/exams\/DEE-1721%20V8.files\/image039.jpg\" v:shapes=\"Picture_x0020_70\"><br><\/div><input type='hidden' name='question_id[]' id='qID_16' value='27235' \/><input type='hidden' id='answerType27235' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27235[]' id='answer-id-112333' class='answer   answerof-27235 ' value='112333'   \/><label for='answer-id-112333' id='answer-label-112333' class=' answer'><span>Option A<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27235[]' id='answer-id-112334' class='answer   answerof-27235 ' value='112334'   \/><label for='answer-id-112334' id='answer-label-112334' class=' answer'><span>Option B<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27235[]' id='answer-id-112335' class='answer   answerof-27235 ' value='112335'   \/><label for='answer-id-112335' id='answer-label-112335' class=' answer'><span>Option C<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27235[]' id='answer-id-112336' class='answer   answerof-27235 ' value='112336'   \/><label for='answer-id-112336' id='answer-label-112336' class=' answer'><span>Option D<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-17' style=';'><div id='questionWrap-17'  class='   watupro-question-id-27236'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>17. <\/span>A company has multiple Storage Centers at their primary site and a disaster recovery system at their remote site. Because there company has an important volume that request high availability protection, an outage on one system at the primary location must not cause data to be inaccessible. In addition, disaster recovery protection is required to protect data even if the primary site goes down. <br \/>\r<br>Which recommended technology meets these requirements?<\/div><input type='hidden' name='question_id[]' id='qID_17' value='27236' \/><input type='hidden' id='answerType27236' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27236[]' id='answer-id-112337' class='answer   answerof-27236 ' value='112337'   \/><label for='answer-id-112337' id='answer-label-112337' class=' answer'><span>Live Volume Managed Replication<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27236[]' id='answer-id-112338' class='answer   answerof-27236 ' value='112338'   \/><label for='answer-id-112338' id='answer-label-112338' class=' answer'><span>Fluid Data Architecture<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27236[]' id='answer-id-112339' class='answer   answerof-27236 ' value='112339'   \/><label for='answer-id-112339' id='answer-label-112339' class=' answer'><span>Synchronous Replication<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27236[]' id='answer-id-112340' class='answer   answerof-27236 ' value='112340'   \/><label for='answer-id-112340' id='answer-label-112340' class=' answer'><span>Asynchronous Replication<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-18' style=';'><div id='questionWrap-18'  class='   watupro-question-id-27237'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>18. <\/span>During the deployment of an SC Series storage array, the redundancy of a tier may be restricted dual redundancy. <br \/>\r<br>What is the cause for this behavior?<\/div><input type='hidden' name='question_id[]' id='qID_18' value='27237' \/><input type='hidden' id='answerType27237' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27237[]' id='answer-id-112341' class='answer   answerof-27237 ' value='112341'   \/><label for='answer-id-112341' id='answer-label-112341' class=' answer'><span>Depending on the drive firmware level and drive sire, Dell Storage Manager will enforce dual redundancy<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27237[]' id='answer-id-112342' class='answer   answerof-27237 ' value='112342'   \/><label for='answer-id-112342' id='answer-label-112342' class=' answer'><span>Depending on the drive speed, drive sire, and SCOS version, dual redundancy may be enforced<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27237[]' id='answer-id-112343' class='answer   answerof-27237 ' value='112343'   \/><label for='answer-id-112343' id='answer-label-112343' class=' answer'><span>Depending on the drive manufacturer and SCOS version, Del Storage Manager will enlace dual redundancy<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27237[]' id='answer-id-112344' class='answer   answerof-27237 ' value='112344'   \/><label for='answer-id-112344' id='answer-label-112344' class=' answer'><span>Depending on the number of spares configured on the system and SCOS version, dual redundancy may be enforced<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-19' style=';'><div id='questionWrap-19'  class='   watupro-question-id-27238'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>19. <\/span>You need to physically install an I\/O card into an SC9000 storage array. <br \/>\r<br>What must be considered when installing the I\/O card?<\/div><input type='hidden' name='question_id[]' id='qID_19' value='27238' \/><input type='hidden' id='answerType27238' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27238[]' id='answer-id-112345' class='answer   answerof-27238 ' value='112345'   \/><label for='answer-id-112345' id='answer-label-112345' class=' answer'><span>I\/O card BIOS and IPC connection<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27238[]' id='answer-id-112346' class='answer   answerof-27238 ' value='112346'   \/><label for='answer-id-112346' id='answer-label-112346' class=' answer'><span>ESD and I\/O slot priority<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27238[]' id='answer-id-112347' class='answer   answerof-27238 ' value='112347'   \/><label for='answer-id-112347' id='answer-label-112347' class=' answer'><span>I\/O slot priority and I\/O card BIOS<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27238[]' id='answer-id-112348' class='answer   answerof-27238 ' value='112348'   \/><label for='answer-id-112348' id='answer-label-112348' class=' answer'><span>IPC connection and ESD<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-20' style=';'><div id='questionWrap-20'  class='   watupro-question-id-27239'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>20. <\/span>A storage administration needs to enable regular Data Progression to move data between storage tiers. While navigating through the Volume Create wizard, which storage profile should be selected?<\/div><input type='hidden' name='question_id[]' id='qID_20' value='27239' \/><input type='hidden' id='answerType27239' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27239[]' id='answer-id-112349' class='answer   answerof-27239 ' value='112349'   \/><label for='answer-id-112349' id='answer-label-112349' class=' answer'><span>Low Priority<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27239[]' id='answer-id-112350' class='answer   answerof-27239 ' value='112350'   \/><label for='answer-id-112350' id='answer-label-112350' class=' answer'><span>Medium Priority<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27239[]' id='answer-id-112351' class='answer   answerof-27239 ' value='112351'   \/><label for='answer-id-112351' id='answer-label-112351' class=' answer'><span>High Priority<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27239[]' id='answer-id-112352' class='answer   answerof-27239 ' value='112352'   \/><label for='answer-id-112352' id='answer-label-112352' class=' answer'><span>Recommended<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-21' style=';'><div id='questionWrap-21'  class='   watupro-question-id-27240'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>21. <\/span>You map a volume to a Microsoft Windows 2012 R2 server and scan for disks within the Windows Disk Management Console. You are able to see multiple Instances of the mapped volume. In addition, the operating system was recently installed on the server that is experiencing the issue. No additional features have been added. <br \/>\r<br>Which action should occur within Windows to correct the issue?<\/div><input type='hidden' name='question_id[]' id='qID_21' value='27240' \/><input type='hidden' id='answerType27240' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27240[]' id='answer-id-112353' class='answer   answerof-27240 ' value='112353'   \/><label for='answer-id-112353' id='answer-label-112353' class=' answer'><span>Add the Storage Center specific harware ID within Windows MPIO \r\nSelect the disk object with the lowest number and delete the rest \r\nVerify the iSCSI Initiator service runs on the server<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27240[]' id='answer-id-112354' class='answer   answerof-27240 ' value='112354'   \/><label for='answer-id-112354' id='answer-label-112354' class=' answer'><span>Add the Storage Center specific harware ID within Windows MPIO \r\nAdd the \u201cMultipath I\/O\u201d server feature \r\nReboot the server after making the correct configuration changes<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27240[]' id='answer-id-112355' class='answer   answerof-27240 ' value='112355'   \/><label for='answer-id-112355' id='answer-label-112355' class=' answer'><span>Select the disk object with the lowest disk number and delete the rest \r\nAdd the \u201cMultipath I\/O\u201d server feature \r\nReboot the server after making the correct configuration changes \r\nVerify the iSCSI Initiator service runs on the server<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-22' style=';'><div id='questionWrap-22'  class='   watupro-question-id-27241'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>22. <\/span>You notice that servers connecting through iSCSI are not performing as expected. After reviewing the graphics, you identify high latency due to an excessive number of retransmissions. <br \/>\r<br>What is causing the performance issue?<\/div><input type='hidden' name='question_id[]' id='qID_22' value='27241' \/><input type='hidden' id='answerType27241' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27241[]' id='answer-id-112356' class='answer   answerof-27241 ' value='112356'   \/><label for='answer-id-112356' id='answer-label-112356' class=' answer'><span>System uses the standard MTU size<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27241[]' id='answer-id-112357' class='answer   answerof-27241 ' value='112357'   \/><label for='answer-id-112357' id='answer-label-112357' class=' answer'><span>Switch firmware is out of date<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27241[]' id='answer-id-112358' class='answer   answerof-27241 ' value='112358'   \/><label for='answer-id-112358' id='answer-label-112358' class=' answer'><span>VLAN ID value is set on the properties of the server NIC<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27241[]' id='answer-id-112359' class='answer   answerof-27241 ' value='112359'   \/><label for='answer-id-112359' id='answer-label-112359' class=' answer'><span>Flow Control is disabled<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-23' style=';'><div id='questionWrap-23'  class='   watupro-question-id-27242'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>23. <\/span>A deployment engineer is installing a dual-controller Storage Center with four FC ports in each controller. This system need to use Legacy Port mode because the AIX version used requires it. <br \/>\r<br>Which two configurations are required to set up the fault domains?<\/div><input type='hidden' name='question_id[]' id='qID_23' value='27242' \/><input type='hidden' id='answerType27242' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27242[]' id='answer-id-112360' class='answer   answerof-27242 ' value='112360'   \/><label for='answer-id-112360' id='answer-label-112360' class=' answer'><span>Only two fault domains; one for the primary ports and one for the reserved ports \r\nPrimary and reserved ports in the fault domain need to reside on the same controller<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27242[]' id='answer-id-112361' class='answer   answerof-27242 ' value='112361'   \/><label for='answer-id-112361' id='answer-label-112361' class=' answer'><span>Only two fault domains; one zone for all ports in each fabric \r\nPrimary and reserved ports in the fault domain need to reside on the different controllers<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27242[]' id='answer-id-112362' class='answer   answerof-27242 ' value='112362'   \/><label for='answer-id-112362' id='answer-label-112362' class=' answer'><span>A separate fault domain for each set of primary and reserved ports \r\nPrimary and reserved ports in the fault domain need to reside on different controllers<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27242[]' id='answer-id-112363' class='answer   answerof-27242 ' value='112363'   \/><label for='answer-id-112363' id='answer-label-112363' class=' answer'><span>A separate fault domain for each set of primary and reserved ports \r\nPrimary and reserved ports in the fault domain need to reside on the same controller<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-24' style=';'><div id='questionWrap-24'  class='   watupro-question-id-27243'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>24. <\/span>You want to perform an SCOS ISO update. <br \/>\r<br>However, you need to determine the BMC IP address first. <br \/>\r<br>What is one way to determine the BMC IP address?<\/div><input type='hidden' name='question_id[]' id='qID_24' value='27243' \/><input type='hidden' id='answerType27243' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27243[]' id='answer-id-112364' class='answer   answerof-27243 ' value='112364'   \/><label for='answer-id-112364' id='answer-label-112364' class=' answer'><span>Select the \u201cHardware\u201d tab from the Data Collector to display the BMC IP address for each controller<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27243[]' id='answer-id-112365' class='answer   answerof-27243 ' value='112365'   \/><label for='answer-id-112365' id='answer-label-112365' class=' answer'><span>Select the \u201cStorage Centers\u201d tab from the Data Collector to display the BMC IP address for each controller<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27243[]' id='answer-id-112366' class='answer   answerof-27243 ' value='112366'   \/><label for='answer-id-112366' id='answer-label-112366' class=' answer'><span>In the Dell Storage Manager Client, highlight the controller under the \u201cHardware\u201d tab and select Edit Settings<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27243[]' id='answer-id-112367' class='answer   answerof-27243 ' value='112367'   \/><label for='answer-id-112367' id='answer-label-112367' class=' answer'><span>Perform a trace route from the controller CLI to the virtual IP address<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-25' style=';'><div id='questionWrap-25'  class='   watupro-question-id-27244'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>25. <\/span>A company experienced complete storage outages on some of their servers. The outages occurred when network maintenance was performed within their iSCSI network. <br \/>\r<br>Which configuration areas should be investigated to prevent future outage?<\/div><input type='hidden' name='question_id[]' id='qID_25' value='27244' \/><input type='hidden' id='answerType27244' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27244[]' id='answer-id-112368' class='answer   answerof-27244 ' value='112368'   \/><label for='answer-id-112368' id='answer-label-112368' class=' answer'><span>Ensure Delayed Acknowledgment has been disabled on the iSCSI adapters. \r\nEnsure all server iSCSI adapter are able to communicate with the storage.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27244[]' id='answer-id-112369' class='answer   answerof-27244 ' value='112369'   \/><label for='answer-id-112369' id='answer-label-112369' class=' answer'><span>Ensure the servers are set up for multipathing with Round Robin. \r\nEnsure Deplayed Acknowledgment has been disabled on the iSCSI dapters.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27244[]' id='answer-id-112370' class='answer   answerof-27244 ' value='112370'   \/><label for='answer-id-112370' id='answer-label-112370' class=' answer'><span>Ensure the iSCSI adapters are set up for Jumbo Frames. \r\nEnsure all server iSCSI adapters are able to communicate with the storage.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-27244[]' id='answer-id-112371' class='answer   answerof-27244 ' value='112371'   \/><label for='answer-id-112371' id='answer-label-112371' class=' answer'><span>Ensure the servers are set up for multipagthing with Round Robin \r\nEnsure all server iSCSI adapters are able to communicate with the storage.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div style='display:none' id='question-26'>\n\t<div class='question-content'>\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\" alt=\"Loading...\" title=\"Loading...\" \/>&nbsp;Loading...\t<\/div>\n<\/div>\n\n<br \/>\n\t\n\t\t\t<div class=\"watupro_buttons flex \" id=\"watuPROButtons919\" >\n\t\t  <div id=\"prev-question\" style=\"display:none;\"><input type=\"button\" value=\"&lt; Previous\" onclick=\"WatuPRO.nextQuestion(event, 'previous');\"\/><\/div>\t\t  \t\t  \t\t   \n\t\t   \t  \t\t<div><input type=\"button\" name=\"action\" class=\"watupro-submit-button\" onclick=\"WatuPRO.submitResult(event)\" id=\"action-button\" value=\"View Results\"  \/>\n\t\t<\/div>\n\t\t<\/div>\n\t\t\n\t<input type=\"hidden\" name=\"quiz_id\" value=\"919\" id=\"watuPROExamID\"\/>\n\t<input type=\"hidden\" name=\"start_time\" id=\"startTime\" value=\"2026-05-06 23:43:05\" \/>\n\t<input type=\"hidden\" name=\"start_timestamp\" id=\"startTimeStamp\" value=\"1778110985\" \/>\n\t<input type=\"hidden\" name=\"question_ids\" value=\"\" \/>\n\t<input type=\"hidden\" name=\"watupro_questions\" value=\"27220:112273,112274,112275,112276 | 27221:112277,112278,112279,112280 | 27222:112281,112282,112283,112284 | 27223:112285,112286,112287,112288 | 27224:112289,112290,112291,112292 | 27225:112293,112294,112295,112296 | 27226:112297,112298,112299,112300 | 27227:112301,112302,112303,112304 | 27228:112305,112306,112307,112308 | 27229:112309,112310,112311,112312 | 27230:112313,112314,112315,112316 | 27231:112317,112318,112319,112320 | 27232:112321,112322,112323,112324 | 27233:112325,112326,112327,112328 | 27234:112329,112330,112331,112332 | 27235:112333,112334,112335,112336 | 27236:112337,112338,112339,112340 | 27237:112341,112342,112343,112344 | 27238:112345,112346,112347,112348 | 27239:112349,112350,112351,112352 | 27240:112353,112354,112355 | 27241:112356,112357,112358,112359 | 27242:112360,112361,112362,112363 | 27243:112364,112365,112366,112367 | 27244:112368,112369,112370,112371\" \/>\n\t<input type=\"hidden\" name=\"no_ajax\" value=\"0\">\t\t\t<\/form>\n\t<p>&nbsp;<\/p>\n<\/div>\n\n<script type=\"text\/javascript\">\n\/\/jQuery(document).ready(function(){\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \t\nvar question_ids = \"27220,27221,27222,27223,27224,27225,27226,27227,27228,27229,27230,27231,27232,27233,27234,27235,27236,27237,27238,27239,27240,27241,27242,27243,27244\";\nWatuPROSettings[919] = {};\nWatuPRO.qArr = question_ids.split(',');\nWatuPRO.exam_id = 919;\t    \nWatuPRO.post_id = 3412;\nWatuPRO.store_progress = 0;\nWatuPRO.curCatPage = 1;\nWatuPRO.requiredIDs=\"0\".split(\",\");\nWatuPRO.hAppID = \"0.63865100 1778110985\";\nvar url = \"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/show_exam.php\";\nWatuPRO.examMode = 1;\nWatuPRO.siteURL=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-admin\/admin-ajax.php\";\nWatuPRO.emailIsNotRequired = 0;\nWatuPROIntel.init(919);\nWatuPRO.inCategoryPages=1;});    \t \n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>DEE-1721 exam is the expert level of Dell EMC SC Series certification, which focuses on the knowledge and activities involved in installing, initializing, configuring, testing, updating, upgrading and troubleshoot the hardware and software of the Dell EMC SC Series Storage products. Real DEE-1721 Dell EMC SC Series Expert exam dumps are online to help you [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5992,125],"tags":[5987,5991,5988,5990,5989],"class_list":["post-3412","post","type-post","status-publish","format-standard","hentry","category-dce","category-dell-emc","tag-dee-1721","tag-dee-1721-braindumps","tag-dee-1721-dumps","tag-dee-1721-dumps-questions","tag-dee-1721-exam-dumps"],"_links":{"self":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/3412","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/comments?post=3412"}],"version-history":[{"count":2,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/3412\/revisions"}],"predecessor-version":[{"id":3415,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/3412\/revisions\/3415"}],"wp:attachment":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/media?parent=3412"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/categories?post=3412"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/tags?post=3412"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}