{"id":127806,"date":"2026-05-25T09:57:05","date_gmt":"2026-05-25T09:57:05","guid":{"rendered":"https:\/\/www.dumpsbase.com\/freedumps\/?p=127806"},"modified":"2026-05-25T09:57:08","modified_gmt":"2026-05-25T09:57:08","slug":"3v0-23-25-updated-dumps-v11-02-your-resource-for-passing-the-advanced-vmware-cloud-foundation-9-0-storage-exam","status":"publish","type":"post","link":"https:\/\/www.dumpsbase.com\/freedumps\/3v0-23-25-updated-dumps-v11-02-your-resource-for-passing-the-advanced-vmware-cloud-foundation-9-0-storage-exam.html","title":{"rendered":"3V0-23.25 Updated Dumps (V11.02) &#8211; Your Resource for Passing the Advanced VMware Cloud Foundation 9.0 Storage Exam"},"content":{"rendered":"\n<p>You are eager to pass the Advanced VMware Cloud Foundation 9.0 Storage (3V0-23.25) exam successfully, so you can come to DumpsBase to download the most updated dumps. The 3V0-23.25 dumps (V11.02) are available with 80 real exam questions, ensuring that you practice these questions to pass your Advanced <strong><em><a href=\"https:\/\/www.dumpsbase.com\/vmware.html\">VMware<\/a><\/em><\/strong> Cloud Foundation 9.0 Storage certification exam. These updated questions are crafted by certified professionals who possess a deep understanding of the 3V0-23.25 exam structure and professional-level difficulty. By utilizing the 3V0-23.25 questions and answers in V11.02, you can strategically focus your study efforts on the most critical topics, entirely bypassing unnecessary content. Start your 3V0-23.25 exam preparation with DumpsBase today. With the most updated 3V0-23.25 dumps (V11.02), the path to Advanced VMware Cloud Foundation 9.0 Storage exam success is both clear and affordable.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">A free demo of VMware 3V0-23.25 dumps (V11.02) is below, offering 25 free questions for reading first:<\/h2>\n\n\n<script>\n\t  window.fbAsyncInit = function() {\n\t    FB.init({\n\t      appId            : '622169541470367',\n\t      autoLogAppEvents : true,\n\t      xfbml            : true,\n\t      version          : 'v3.1'\n\t    });\n\t  };\n\t\n\t  (function(d, s, id){\n\t     var js, fjs = d.getElementsByTagName(s)[0];\n\t     if (d.getElementById(id)) {return;}\n\t     js = d.createElement(s); js.id = id;\n\t     js.src = \"https:\/\/connect.facebook.net\/en_US\/sdk.js\";\n\t     fjs.parentNode.insertBefore(js, fjs);\n\t   }(document, 'script', 'facebook-jssdk'));\n\t<\/script><script type=\"text\/javascript\" >\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \nif(!window.jQuery) alert(\"The important jQuery library is not properly loaded in your site. Your WordPress theme is probably missing the essential wp_head() call. You can switch to another theme and you will see that the plugin works fine and this notice disappears. If you are still not sure what to do you can contact us for help.\");\n});\n<\/script>  \n  \n<div  id=\"watupro_quiz\" class=\"quiz-area single-page-quiz\">\n<p id=\"submittingExam12437\" style=\"display:none;text-align:center;\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\"><\/p>\n\n<div class=\"watupro-exam-description\" id=\"description-quiz-12437\"><\/div>\n\n<form action=\"\" method=\"post\" class=\"quiz-form\" id=\"quiz-12437\"  enctype=\"multipart\/form-data\" >\n<div class='watu-question ' id='question-1' style=';'><div id='questionWrap-1'  class='   watupro-question-id-484300'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>1. <\/span>An administrator wants to protect a site from disaster and re-protect after fail-over. Industry regulations require to change the primary site every six months. <br \/>\r<br>Which two options are required during the inventory mapping and while running the recovery plans to fulfill this requirement? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_1' value='484300' \/><input type='hidden' id='answerType484300' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484300[]' id='answer-id-1870695' class='answer   answerof-484300 ' value='1870695'   \/><label for='answer-id-1870695' id='answer-label-1870695' class=' answer'><span>Once fail-over is successful, reconfigure vSAN data protection to reverse replication.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484300[]' id='answer-id-1870696' class='answer   answerof-484300 ' value='1870696'   \/><label for='answer-id-1870696' id='answer-label-1870696' class=' answer'><span>Use \u201cPrepare reverse mappings\u201d during inventory mapping creation.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484300[]' id='answer-id-1870697' class='answer   answerof-484300 ' value='1870697'   \/><label for='answer-id-1870697' id='answer-label-1870697' class=' answer'><span>Use a test recovery plan.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484300[]' id='answer-id-1870698' class='answer   answerof-484300 ' value='1870698'   \/><label for='answer-id-1870698' id='answer-label-1870698' class=' answer'><span>Once the fail-over is successful, re-protect from VMware Live Site Recovery.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484300[]' id='answer-id-1870699' class='answer   answerof-484300 ' value='1870699'   \/><label for='answer-id-1870699' id='answer-label-1870699' class=' answer'><span>Extend the network between both sites.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-2' style=';'><div id='questionWrap-2'  class='   watupro-question-id-484301'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>2. <\/span>An administrator just built a new workload domain including a vSAN ESA cluster. The architecture design included the use of memory tiering and a specific smaller NVMe device has been installed in each ESX host for this purpose. <br \/>\r<br>When looking in the vSphere UI, the administrator notices that the device intended to be used for memory tiering has been claimed by vSAN. <br \/>\r<br>What action should be taken on each host to achieve the desired configuration?<\/div><input type='hidden' name='question_id[]' id='qID_2' value='484301' \/><input type='hidden' id='answerType484301' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484301[]' id='answer-id-1870700' class='answer   answerof-484301 ' value='1870700'   \/><label for='answer-id-1870700' id='answer-label-1870700' class=' answer'><span>Boot the host one time with the tiering device removed, then shut down again. Reconnect the tiering device and boot the host.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484301[]' id='answer-id-1870701' class='answer   answerof-484301 ' value='1870701'   \/><label for='answer-id-1870701' id='answer-label-1870701' class=' answer'><span>Change vSAN disk claiming from automatic to manual and sequentially reboot each ESX host of the cluster after putting them in maintenance mode using the \u201cEnsure Accessibility\u201d option.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484301[]' id='answer-id-1870702' class='answer   answerof-484301 ' value='1870702'   \/><label for='answer-id-1870702' id='answer-label-1870702' class=' answer'><span>After turning on the LED on the memory tiering device, hot remove it from the ESX host; vSAN will rebuild the required objects.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484301[]' id='answer-id-1870703' class='answer   answerof-484301 ' value='1870703'   \/><label for='answer-id-1870703' id='answer-label-1870703' class=' answer'><span>Remove the device from vSAN performing a full data migration and configure that device for memory tiering.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-3' style=';'><div id='questionWrap-3'  class='   watupro-question-id-484302'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>3. <\/span>An administrator is tasked with setting up immutable snapshots for recovery in case of a cyber-attack.<br \/>\r\n<br \/>\r\nWhich two limitations apply when configuring immutable snapshots? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_3' value='484302' \/><input type='hidden' id='answerType484302' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484302[]' id='answer-id-1870704' class='answer   answerof-484302 ' value='1870704'   \/><label for='answer-id-1870704' id='answer-label-1870704' class=' answer'><span>The protection group cannot be both replicated and immutable.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484302[]' id='answer-id-1870705' class='answer   answerof-484302 ' value='1870705'   \/><label for='answer-id-1870705' id='answer-label-1870705' class=' answer'><span>Virtual Machine hardware must be at least version 10.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484302[]' id='answer-id-1870706' class='answer   answerof-484302 ' value='1870706'   \/><label for='answer-id-1870706' id='answer-label-1870706' class=' answer'><span>The Virtual Machine cannot be part of multiple protection groups.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484302[]' id='answer-id-1870707' class='answer   answerof-484302 ' value='1870707'   \/><label for='answer-id-1870707' id='answer-label-1870707' class=' answer'><span>Virtual machine hardware cannot be changed on VM having immutable snapshots.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484302[]' id='answer-id-1870708' class='answer   answerof-484302 ' value='1870708'   \/><label for='answer-id-1870708' id='answer-label-1870708' class=' answer'><span>The protection group cannot have more than 7 snapshot schedules.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-4' style=';'><div id='questionWrap-4'  class='   watupro-question-id-484303'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>4. <\/span>An administrator needs to quickly test a possibly destructive change to a Virtual Machine (VM) in production. The VM is currently protected by vSAN Data Protection. <br \/>\r<br>Which feature of vSAN Data Protection can be leveraged to achieve this objective?<\/div><input type='hidden' name='question_id[]' id='qID_4' value='484303' \/><input type='hidden' id='answerType484303' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484303[]' id='answer-id-1870709' class='answer   answerof-484303 ' value='1870709'   \/><label for='answer-id-1870709' id='answer-label-1870709' class=' answer'><span>Immutable snapshots<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484303[]' id='answer-id-1870710' class='answer   answerof-484303 ' value='1870710'   \/><label for='answer-id-1870710' id='answer-label-1870710' class=' answer'><span>Multiple snapshot schedules<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484303[]' id='answer-id-1870711' class='answer   answerof-484303 ' value='1870711'   \/><label for='answer-id-1870711' id='answer-label-1870711' class=' answer'><span>Protection group<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484303[]' id='answer-id-1870712' class='answer   answerof-484303 ' value='1870712'   \/><label for='answer-id-1870712' id='answer-label-1870712' class=' answer'><span>Linked clone<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484303[]' id='answer-id-1870713' class='answer   answerof-484303 ' value='1870713'   \/><label for='answer-id-1870713' id='answer-label-1870713' class=' answer'><span>Replication<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-5' style=';'><div id='questionWrap-5'  class='   watupro-question-id-484304'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>5. <\/span>A storage administrator is being presented with the following VMware Cloud Foundation (VCF) architectural details: <br \/>\r<br>- The applications data will require 2.5 PB of capacity. <br \/>\r<br>- The production applications will be hosting archival solutions and gateways. <br \/>\r<br>- There will be some applications deployed for the purpose of testing and development. <br \/>\r<br>What is the optimal principal storage that the administrator can recommend?<\/div><input type='hidden' name='question_id[]' id='qID_5' value='484304' \/><input type='hidden' id='answerType484304' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484304[]' id='answer-id-1870714' class='answer   answerof-484304 ' value='1870714'   \/><label for='answer-id-1870714' id='answer-label-1870714' class=' answer'><span>vSAN OSA - All Flash<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484304[]' id='answer-id-1870715' class='answer   answerof-484304 ' value='1870715'   \/><label for='answer-id-1870715' id='answer-label-1870715' class=' answer'><span>vSAN ESA<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484304[]' id='answer-id-1870716' class='answer   answerof-484304 ' value='1870716'   \/><label for='answer-id-1870716' id='answer-label-1870716' class=' answer'><span>vSAN ESA Storage Clusters<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484304[]' id='answer-id-1870717' class='answer   answerof-484304 ' value='1870717'   \/><label for='answer-id-1870717' id='answer-label-1870717' class=' answer'><span>vSAN OSA - Hybrid<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-6' style=';'><div id='questionWrap-6'  class='   watupro-question-id-484305'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>6. <\/span>An administrator has been tasked with suggesting storage models for a new VMware Cloud Foundation (VCF) Private Cloud with the following characteristics: <br \/>\r<br>- Single VCF Instance with a single Workload Domain. <br \/>\r<br>- The VCF Management Workload Domain will consist of a single cluster that uses a highly scalable, integrated storage solution that does not require additional management software or hardware. <br \/>\r<br>- The VCF Workload Domain consists of with a single Cluster that requires a multiple tier storage solution consisting of: <br \/>\r<br>o A highly scalable, policy-based storage solution for critical application workloads.s. <br \/>\r<br>o A file-based storage solution that can scale independently of the cluster for workloads with large data requirements. <br \/>\r<br>Which three storage models should the administrator recommend? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_6' value='484305' \/><input type='hidden' id='answerType484305' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484305[]' id='answer-id-1870718' class='answer   answerof-484305 ' value='1870718'   \/><label for='answer-id-1870718' id='answer-label-1870718' class=' answer'><span>VMware vSAN should be the principal storage solution for the VCF Management Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484305[]' id='answer-id-1870719' class='answer   answerof-484305 ' value='1870719'   \/><label for='answer-id-1870719' id='answer-label-1870719' class=' answer'><span>VMware vSAN should be the principal storage solution for the VCF Workload Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484305[]' id='answer-id-1870720' class='answer   answerof-484305 ' value='1870720'   \/><label for='answer-id-1870720' id='answer-label-1870720' class=' answer'><span>iSCSI should be the supplemental storage solution for the VCF Workload Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484305[]' id='answer-id-1870721' class='answer   answerof-484305 ' value='1870721'   \/><label for='answer-id-1870721' id='answer-label-1870721' class=' answer'><span>iSCSI should be the principal storage solution for the VCF Management Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484305[]' id='answer-id-1870722' class='answer   answerof-484305 ' value='1870722'   \/><label for='answer-id-1870722' id='answer-label-1870722' class=' answer'><span>NFS v3 should be the supplemental storage solution for the VCF Workload Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484305[]' id='answer-id-1870723' class='answer   answerof-484305 ' value='1870723'   \/><label for='answer-id-1870723' id='answer-label-1870723' class=' answer'><span>NFS v4.1 should be the principal storage solution for the VCF Management Domain.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-7' style=';'><div id='questionWrap-7'  class='   watupro-question-id-484306'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>7. <\/span>An administrator is tasked with stretching a vSAN cluster in a VMware Cloud Foundation (VCF) Workload Domain across two availability zones within a region. Both availability zones contain an equal number of hosts.<br \/>\r\n<br \/>\r\nWhat four Conditions must also be met in order to stretch the cluster?<br \/>\r\n<br \/>\r\nDrag and drop the four correct options from the Options list on the left and place them into the Conditions on the right in any order. (Choose four.)<br \/>\r\n<br \/>\r\n<br \/>\r\n<img loading=\"lazy\" decoding=\"async\" id=\"\u56fe\u7247 20\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image007-24.jpg\" width=\"649\" height=\"145\" \/><\/div><input type='hidden' name='question_id[]' id='qID_7' value='484306' \/><input type='hidden' id='answerType484306' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484306[]' id='answer-id-1870724' class='answer   answerof-484306 ' value='1870724'   \/><label for='answer-id-1870724' id='answer-label-1870724' class=' answer'><span><br><img decoding=\"async\" width=649 height=145 id=\"\u56fe\u7247 19\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image008-28.jpg\"><br><\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-8' style=';'><div id='questionWrap-8'  class='   watupro-question-id-484307'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>8. <\/span>A vSAN ESA cluster experienced a host NVMe failure, causing several objects to become non-compliant. Select the steps vSAN ESA follows to detect, evaluate and repair the non-compliant objects.<br \/>\r\n<br \/>\r\nDrag and drop the four correct options from the Options list on the left and place them into the Required Options on the right in any order. (Choose four.)<br \/>\r\n<br \/>\r\n<br \/>\r\n<img loading=\"lazy\" decoding=\"async\" id=\"\u56fe\u7247 18\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image009-29.jpg\" width=\"649\" height=\"142\" \/><\/div><input type='hidden' name='question_id[]' id='qID_8' value='484307' \/><input type='hidden' id='answerType484307' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484307[]' id='answer-id-1870725' class='answer   answerof-484307 ' value='1870725'   \/><label for='answer-id-1870725' id='answer-label-1870725' class=' answer'><span><br><img decoding=\"async\" width=649 height=142 id=\"\u56fe\u7247 17\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image010-25.jpg\"><br><\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-9' style=';'><div id='questionWrap-9'  class='   watupro-question-id-484308'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>9. <\/span>An administrator is tasked with designing a highly available vSAN ESA two node cluster for a remote VMware Cloud Foundation (VCF) workload domain that provides a maximum secondary Failures To Tolerate (FTT). <br \/>\r<br>What is the minimum total number of nested fault domains required for the design?<\/div><input type='hidden' name='question_id[]' id='qID_9' value='484308' \/><input type='hidden' id='answerType484308' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484308[]' id='answer-id-1870726' class='answer   answerof-484308 ' value='1870726'   \/><label for='answer-id-1870726' id='answer-label-1870726' class=' answer'><span>7<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484308[]' id='answer-id-1870727' class='answer   answerof-484308 ' value='1870727'   \/><label for='answer-id-1870727' id='answer-label-1870727' class=' answer'><span>4<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484308[]' id='answer-id-1870728' class='answer   answerof-484308 ' value='1870728'   \/><label for='answer-id-1870728' id='answer-label-1870728' class=' answer'><span>2<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484308[]' id='answer-id-1870729' class='answer   answerof-484308 ' value='1870729'   \/><label for='answer-id-1870729' id='answer-label-1870729' class=' answer'><span>6<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-10' style=';'><div id='questionWrap-10'  class='   watupro-question-id-484309'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>10. <\/span>After a planned power outage, an administrator decided to restart the vSAN cluster manually.<br \/>\r\n<br \/>\r\nDrag and drop the three correct options from the Options list on the left and place them into the Required Options on the right in any order. (Choose three.)<br \/>\r\n<br \/>\r\n<br \/>\r\n<img loading=\"lazy\" decoding=\"async\" id=\"\u56fe\u7247 22\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image005-28.jpg\" width=\"649\" height=\"115\" \/><\/div><input type='hidden' name='question_id[]' id='qID_10' value='484309' \/><input type='hidden' id='answerType484309' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484309[]' id='answer-id-1870730' class='answer   answerof-484309 ' value='1870730'   \/><label for='answer-id-1870730' id='answer-label-1870730' class=' answer'><span><br><img decoding=\"async\" width=649 height=115 id=\"\u56fe\u7247 3\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image006-23.jpg\"><br><\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-11' style=';'><div id='questionWrap-11'  class='   watupro-question-id-484310'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>11. <\/span>A vSAN ESA solution is configured using the following requirements: <br \/>\r<br>- Seven ESX Hosts, each host contains: <br \/>\r<br>- 32 CPU <br \/>\r<br>- 256 GB memory <br \/>\r<br>- 25 GbE network <br \/>\r<br>- 12 storage devices 4TB each <br \/>\r<br>- One storage pool using the 12 storage devices <br \/>\r<br>- RAID 6 with FTT=2 <br \/>\r<br>If a storage device on a single host fails, what percentage of that host's capacity is impacted?<\/div><input type='hidden' name='question_id[]' id='qID_11' value='484310' \/><input type='hidden' id='answerType484310' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484310[]' id='answer-id-1870731' class='answer   answerof-484310 ' value='1870731'   \/><label for='answer-id-1870731' id='answer-label-1870731' class=' answer'><span>8.3%<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484310[]' id='answer-id-1870732' class='answer   answerof-484310 ' value='1870732'   \/><label for='answer-id-1870732' id='answer-label-1870732' class=' answer'><span>50%<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484310[]' id='answer-id-1870733' class='answer   answerof-484310 ' value='1870733'   \/><label for='answer-id-1870733' id='answer-label-1870733' class=' answer'><span>25%<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484310[]' id='answer-id-1870734' class='answer   answerof-484310 ' value='1870734'   \/><label for='answer-id-1870734' id='answer-label-1870734' class=' answer'><span>10%<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-12' style=';'><div id='questionWrap-12'  class='   watupro-question-id-484311'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>12. <\/span>A cache drive failed on one of the vSAN OSA nodes in the cluster. <br \/>\r<br>When the drive failed, vSAN started a resync to ensure the health of the data, and all objects are showing a healthy and compliant state. <br \/>\r<br>The vSAN administrator needs to replace the failed cache drive. <br \/>\r<br>Which set of steps should the vSAN administrator take?<\/div><input type='hidden' name='question_id[]' id='qID_12' value='484311' \/><input type='hidden' id='answerType484311' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484311[]' id='answer-id-1870735' class='answer   answerof-484311 ' value='1870735'   \/><label for='answer-id-1870735' id='answer-label-1870735' class=' answer'><span>Physically replace the failed cache device, and vSAN will automatically allocate the storage.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484311[]' id='answer-id-1870736' class='answer   answerof-484311 ' value='1870736'   \/><label for='answer-id-1870736' id='answer-label-1870736' class=' answer'><span>Place the disk group into maintenance mode and select Full Data Migration, then physically replace the failed cache device afterwards. vSAN will rebuild the disk group automatically.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484311[]' id='answer-id-1870737' class='answer   answerof-484311 ' value='1870737'   \/><label for='answer-id-1870737' id='answer-label-1870737' class=' answer'><span>Remove the existing vSAN disk group, and physically replace the device. Then check to verify that the ESXi host automatically detects the new device. Afterwards, manually recreate the disk group.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484311[]' id='answer-id-1870738' class='answer   answerof-484311 ' value='1870738'   \/><label for='answer-id-1870738' id='answer-label-1870738' class=' answer'><span>Physically replace the failed cache device, and vSAN will automatically create a new disk group. Then, remove the disk group with the failed device.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-13' style=';'><div id='questionWrap-13'  class='   watupro-question-id-484312'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>13. <\/span>An administrator is responsible for a VMware Cloud Foundation (VCF) Private Cloud has been tasked with identifying which storage model is supported in the different VCF Workload Domains.<br \/>\r\n<br \/>\r\nDrag and drop the Support Status of each storage model on the left to each type of Workload Domain on the right.<br \/>\r\n<br \/>\r\n<br \/>\r\n<img loading=\"lazy\" decoding=\"async\" id=\"\u56fe\u7247 26\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image001-43.jpg\" width=\"649\" height=\"225\" \/><\/div><input type='hidden' name='question_id[]' id='qID_13' value='484312' \/><input type='hidden' id='answerType484312' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484312[]' id='answer-id-1870739' class='answer   answerof-484312 ' value='1870739'   \/><label for='answer-id-1870739' id='answer-label-1870739' class=' answer'><span><br><img decoding=\"async\" width=649 height=224 id=\"\u56fe\u7247 25\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image002-41.jpg\"><br><\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-14' style=';'><div id='questionWrap-14'  class='   watupro-question-id-484313'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>14. <\/span>An administrator reports that after rebooting one host in a vSAN cluster configured with Data-at-Rest Encryption using an external Key Management Server (KMS), the host shows all vSAN disk groups as unmounted. <br \/>\r<br>The KMS is online and reachable from all hosts. <br \/>\r<br>In vCenter, the host displays the following event: <br \/>\r<br>\u201cFailed to retrieve encryption key from KMS.\u201d <br \/>\r<br>Key ID: <br \/>\r<br>All other hosts in the cluster remain healthy and show \u201cEncryption: Enabled.\u201d <br \/>\r<br>Why did the encryption key retrieval fail for this host?<\/div><input type='hidden' name='question_id[]' id='qID_14' value='484313' \/><input type='hidden' id='answerType484313' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484313[]' id='answer-id-1870740' class='answer   answerof-484313 ' value='1870740'   \/><label for='answer-id-1870740' id='answer-label-1870740' class=' answer'><span>The host\u2019s trust relationship or certificate with the KMS is invalid or missing.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484313[]' id='answer-id-1870741' class='answer   answerof-484313 ' value='1870741'   \/><label for='answer-id-1870741' id='answer-label-1870741' class=' answer'><span>The cluster requires a Deep Rekey operation to restore access to the encrypted disks.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484313[]' id='answer-id-1870742' class='answer   answerof-484313 ' value='1870742'   \/><label for='answer-id-1870742' id='answer-label-1870742' class=' answer'><span>The vCenter Server has not been restarted to refresh the encryption key cache.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484313[]' id='answer-id-1870743' class='answer   answerof-484313 ' value='1870743'   \/><label for='answer-id-1870743' id='answer-label-1870743' class=' answer'><span>The TPM on the host failed to unlock the data encryption keys.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-15' style=';'><div id='questionWrap-15'  class='   watupro-question-id-484314'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>15. <\/span>A administrator is deploying a vSphere Supervisor Cluster on a VMware Cloud Foundation (VCF) Workload Domain that uses NFS storage. As part of the configuration, the administrator must define separate storage policies for container images, ephemeral volumes, and persistent volumes within the vSphere Namespace. <br \/>\r<br>The solution must align with vSphere Storage Policy Based Management (SPBM) and Broadcom TechDocs recommendations for supported Supervisor configurations. <br \/>\r<br>Which configuration meets these requirements?<\/div><input type='hidden' name='question_id[]' id='qID_15' value='484314' \/><input type='hidden' id='answerType484314' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484314[]' id='answer-id-1870744' class='answer   answerof-484314 ' value='1870744'   \/><label for='answer-id-1870744' id='answer-label-1870744' class=' answer'><span>Define one default storage policy and allow the Supervisor control plane to automatically create sub-policies for container and persistent workloads during namespace provisioning.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484314[]' id='answer-id-1870745' class='answer   answerof-484314 ' value='1870745'   \/><label for='answer-id-1870745' id='answer-label-1870745' class=' answer'><span>Create three SPBM storage policies that all reference the same shared NFS datastore. Assign these policies respectively to container images, ephemeral volumes, and persistent volumes when enabling Workload Management to logically isolate the volume types within a single datastore.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484314[]' id='answer-id-1870746' class='answer   answerof-484314 ' value='1870746'   \/><label for='answer-id-1870746' id='answer-label-1870746' class=' answer'><span>Use datastore clusters to automatically balance storage consumption for container and persistent volumes, and rely on vSphere DRS to place ephemeral data dynamically across datastores.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484314[]' id='answer-id-1870747' class='answer   answerof-484314 ' value='1870747'   \/><label for='answer-id-1870747' id='answer-label-1870747' class=' answer'><span>Create three distinct SPBM storage policies, each mapped to a dedicated shared NFS datastore. Assign these policies to the corresponding storage options (container images, ephemeral volumes, and persistent volumes) during Supervisor deployment.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-16' style=';'><div id='questionWrap-16'  class='   watupro-question-id-484315'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>16. <\/span>An administrator is planning the deployment of a new VMware Cloud Foundation (VCF) Workload Domain. <br \/>\r<br>The storage design decisions for the solution are: <br \/>\r<br>&#8226; NFS <br \/>\r<br>&#8226; NVMe over RDMA <br \/>\r<br>&#8226; No local storage is available to the hosts <br \/>\r<br>What is the storage solution build order for the Workload Domain?<\/div><input type='hidden' name='question_id[]' id='qID_16' value='484315' \/><input type='hidden' id='answerType484315' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484315[]' id='answer-id-1870748' class='answer   answerof-484315 ' value='1870748'   \/><label for='answer-id-1870748' id='answer-label-1870748' class=' answer'><span>vSAN OSA as principal storage, then add NFS and NVMe over RDMA as supplemental storage.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484315[]' id='answer-id-1870749' class='answer   answerof-484315 ' value='1870749'   \/><label for='answer-id-1870749' id='answer-label-1870749' class=' answer'><span>vSAN ESA as principal storage, then add NFS and NVMe over RDMA as supplemental storage.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484315[]' id='answer-id-1870750' class='answer   answerof-484315 ' value='1870750'   \/><label for='answer-id-1870750' id='answer-label-1870750' class=' answer'><span>NVMe over RDMA as principal storage, then add NFS as supplemental storage.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484315[]' id='answer-id-1870751' class='answer   answerof-484315 ' value='1870751'   \/><label for='answer-id-1870751' id='answer-label-1870751' class=' answer'><span>NFS as principal storage, then add NVMe over RDMA as supplemental storage.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-17' style=';'><div id='questionWrap-17'  class='   watupro-question-id-484316'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>17. <\/span>An administrator is tasked designing a vSAN storage solution while respecting the following requirements: <br \/>\r<br>&#8226; Must use vSAN ESA <br \/>\r<br>&#8226; Must be stretched between two data centers <br \/>\r<br>&#8226; Must configure Failures to tolerate = 1 <br \/>\r<br>&#8226; Must configure Erasure Coding <br \/>\r<br>How many components per Virtual Machine (VM) will be created?<\/div><input type='hidden' name='question_id[]' id='qID_17' value='484316' \/><input type='hidden' id='answerType484316' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484316[]' id='answer-id-1870752' class='answer   answerof-484316 ' value='1870752'   \/><label for='answer-id-1870752' id='answer-label-1870752' class=' answer'><span>4<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484316[]' id='answer-id-1870753' class='answer   answerof-484316 ' value='1870753'   \/><label for='answer-id-1870753' id='answer-label-1870753' class=' answer'><span>3<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484316[]' id='answer-id-1870754' class='answer   answerof-484316 ' value='1870754'   \/><label for='answer-id-1870754' id='answer-label-1870754' class=' answer'><span>1<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484316[]' id='answer-id-1870755' class='answer   answerof-484316 ' value='1870755'   \/><label for='answer-id-1870755' id='answer-label-1870755' class=' answer'><span>2<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-18' style=';'><div id='questionWrap-18'  class='   watupro-question-id-484317'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>18. <\/span>An administrator is tasked with deploying a vSAN ESA Stretched cluster for a VMware Cloud Foundation (VCF) workload domain. <br \/>\r<br>The stretched cluster must meet the following requirements: <br \/>\r<br>- Ensure the cluster supports a storage policy with a secondary level of resilience of FTT=2 using RAID-6 erasure coding. <br \/>\r<br>- Allow vSAN to regain its prescribed level of resilience in the event of a sustained host outage. <br \/>\r<br>What is the minimum number of hosts required in each availability zone?<\/div><input type='hidden' name='question_id[]' id='qID_18' value='484317' \/><input type='hidden' id='answerType484317' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484317[]' id='answer-id-1870756' class='answer   answerof-484317 ' value='1870756'   \/><label for='answer-id-1870756' id='answer-label-1870756' class=' answer'><span>14<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484317[]' id='answer-id-1870757' class='answer   answerof-484317 ' value='1870757'   \/><label for='answer-id-1870757' id='answer-label-1870757' class=' answer'><span>7<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484317[]' id='answer-id-1870758' class='answer   answerof-484317 ' value='1870758'   \/><label for='answer-id-1870758' id='answer-label-1870758' class=' answer'><span>6<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484317[]' id='answer-id-1870759' class='answer   answerof-484317 ' value='1870759'   \/><label for='answer-id-1870759' id='answer-label-1870759' class=' answer'><span>12<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-19' style=';'><div id='questionWrap-19'  class='   watupro-question-id-484318'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>19. <\/span>A VMware Cloud Foundation (VCF) environment runs mixed workloads (Online Transaction Processing (OLTP) + analytics), with the following vSAN configuration: <br \/>\r<br>- 8 hosts (all-flash), ESA enabled. <br \/>\r<br>- Each host: 2x3.2TB NVMe devices. <br \/>\r<br>- Compression is Enabled. <br \/>\r<br>- Checksum is Enabled. <br \/>\r<br>- Storage Policy: FTT=1 (RAID-5\/6), Failures to Tolerate = 1 and Object Space Reservation =0%. <br \/>\r<br>During peak OLTP load, vSAN resync I\/O and backend congestion increase latency despite having sufficient network bandwidth. <br \/>\r<br>What is the direct action the administrator can perform to improve write performance while maintaining data protection compliance?<\/div><input type='hidden' name='question_id[]' id='qID_19' value='484318' \/><input type='hidden' id='answerType484318' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484318[]' id='answer-id-1870760' class='answer   answerof-484318 ' value='1870760'   \/><label for='answer-id-1870760' id='answer-label-1870760' class=' answer'><span>Increase FTT to 2 with RAID-5\/6 and disable compression.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484318[]' id='answer-id-1870761' class='answer   answerof-484318 ' value='1870761'   \/><label for='answer-id-1870761' id='answer-label-1870761' class=' answer'><span>Convert policy to RAID-1(FTT=1) for latency-sensitive workloads while keeping compression enabled.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484318[]' id='answer-id-1870762' class='answer   answerof-484318 ' value='1870762'   \/><label for='answer-id-1870762' id='answer-label-1870762' class=' answer'><span>Increase object reservation to 100% to pre-allocate capacity and prevent log-structuring overhead.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484318[]' id='answer-id-1870763' class='answer   answerof-484318 ' value='1870763'   \/><label for='answer-id-1870763' id='answer-label-1870763' class=' answer'><span>Disable checksums to reduce metadata writes on NVMe devices.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-20' style=';'><div id='questionWrap-20'  class='   watupro-question-id-484319'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>20. <\/span>An administrator is responsible for a VMware Cloud Foundation (VCF) Private Cloud has been tasked with identifying which storage model is supported in the different VCF Workload Domains.<br \/>\r\n<br \/>\r\nDrag and drop the Support Status of each storage model on the left to each type of Workload Domain on the right.<br \/>\r\n<br \/>\r\n<br \/>\r\n<img loading=\"lazy\" decoding=\"async\" id=\"\u56fe\u7247 24\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image003-31.jpg\" width=\"649\" height=\"198\" \/><\/div><input type='hidden' name='question_id[]' id='qID_20' value='484319' \/><input type='hidden' id='answerType484319' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484319[]' id='answer-id-1870764' class='answer   answerof-484319 ' value='1870764'   \/><label for='answer-id-1870764' id='answer-label-1870764' class=' answer'><span><br><img decoding=\"async\" width=649 height=198 id=\"\u56fe\u7247 23\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2026\/05\/image004-27.jpg\"><br><\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-21' style=';'><div id='questionWrap-21'  class='   watupro-question-id-484320'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>21. <\/span>An administrator is managing a local vSAN 3-node cluster running the Express Storage Architecture (ESA) as part of a VMware Cloud Foundation (VCF) Workload Domain. <br \/>\r<br>The following parameters apply at the cluster level: <br \/>\r<br>- HA is enabled <br \/>\r<br>- Reserved Failover Capacity = 25% for both CPU and Memory <br \/>\r<br>The administrator is tasked with configuring the VSAN storage policy so it will tolerate the maximum number of failures. <br \/>\r<br>What two protection levels can the administrator configure? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_21' value='484320' \/><input type='hidden' id='answerType484320' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484320[]' id='answer-id-1870765' class='answer   answerof-484320 ' value='1870765'   \/><label for='answer-id-1870765' id='answer-label-1870765' class=' answer'><span>RAID-1 (Mirroring) 1 Failure.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484320[]' id='answer-id-1870766' class='answer   answerof-484320 ' value='1870766'   \/><label for='answer-id-1870766' id='answer-label-1870766' class=' answer'><span>No data redundancy.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484320[]' id='answer-id-1870767' class='answer   answerof-484320 ' value='1870767'   \/><label for='answer-id-1870767' id='answer-label-1870767' class=' answer'><span>RAID-6 (Erasure Coding) 2 Failures.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484320[]' id='answer-id-1870768' class='answer   answerof-484320 ' value='1870768'   \/><label for='answer-id-1870768' id='answer-label-1870768' class=' answer'><span>RAID-5 (Erasure Coding) 1 Failure.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484320[]' id='answer-id-1870769' class='answer   answerof-484320 ' value='1870769'   \/><label for='answer-id-1870769' id='answer-label-1870769' class=' answer'><span>RAID-1 (Mirroring) 3 Failures.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484320[]' id='answer-id-1870770' class='answer   answerof-484320 ' value='1870770'   \/><label for='answer-id-1870770' id='answer-label-1870770' class=' answer'><span>RAID-1 (Mirroring) 2 Failures.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-22' style=';'><div id='questionWrap-22'  class='   watupro-question-id-484321'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>22. <\/span>An architect has been tasked with designing a vSAN OSA storage solution for a VMware Cloud Foundation (VCF) Private Cloud. <br \/>\r<br>The following requirements and constraints have been gathered from the client: <br \/>\r<br>&#8226; 2 x 4 TB NVMe disks per host <br \/>\r<br>&#8226; 6 hosts <br \/>\r<br>&#8226; FTT=1\/RAID-5 for all deployed Virtual Machines <br \/>\r<br>&#8226; Expected Dedupe\/Compression Ratio = 2 (100%) <br \/>\r<br>&#8226; Reserve enough capacity to rebuild a host completely in case of a failure (Host Rebuild Reservation) <br \/>\r<br>&#8226; Operational Reserve of 10% <br \/>\r<br>&#8226; Expected Overhead for Filesystem, Object, etc. of 25% <br \/>\r<br>What is the approximate expected usable capacity of the resulting array?<\/div><input type='hidden' name='question_id[]' id='qID_22' value='484321' \/><input type='hidden' id='answerType484321' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484321[]' id='answer-id-1870771' class='answer   answerof-484321 ' value='1870771'   \/><label for='answer-id-1870771' id='answer-label-1870771' class=' answer'><span>48 TB<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484321[]' id='answer-id-1870772' class='answer   answerof-484321 ' value='1870772'   \/><label for='answer-id-1870772' id='answer-label-1870772' class=' answer'><span>32 TB<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484321[]' id='answer-id-1870773' class='answer   answerof-484321 ' value='1870773'   \/><label for='answer-id-1870773' id='answer-label-1870773' class=' answer'><span>40 TB<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484321[]' id='answer-id-1870774' class='answer   answerof-484321 ' value='1870774'   \/><label for='answer-id-1870774' id='answer-label-1870774' class=' answer'><span>24 TB<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-23' style=';'><div id='questionWrap-23'  class='   watupro-question-id-484322'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>23. <\/span>An administrator has been tasked with suggesting storage models for a new VMware Cloud Foundation (VCF) Private Cloud with the following characteristics: <br \/>\r<br>&#8226; Single VCF Instance with a single Workload Domain. <br \/>\r<br>&#8226; The VCF Management Workload Domain will consist of a single cluster that uses a highly scalable, integrated storage solution that does not require additional management software or hardware. <br \/>\r<br>&#8226; The VCF Workload Domain consists of a single Cluster that requires a multiple-tier storage solution consisting of: <br \/>\r<br>- A highly scalable, policy-based storage solution for critical application workloads. <br \/>\r<br>- A file-based storage solution that can scale independently of the cluster for workloads with large data requirements. <br \/>\r<br>Which three storage models should the administrator recommend? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_23' value='484322' \/><input type='hidden' id='answerType484322' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484322[]' id='answer-id-1870775' class='answer   answerof-484322 ' value='1870775'   \/><label for='answer-id-1870775' id='answer-label-1870775' class=' answer'><span>NFS v3 should be the supplemental storage solution for the VCF Workload Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484322[]' id='answer-id-1870776' class='answer   answerof-484322 ' value='1870776'   \/><label for='answer-id-1870776' id='answer-label-1870776' class=' answer'><span>iSCSI should be the principal storage solution for the VCF Management Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484322[]' id='answer-id-1870777' class='answer   answerof-484322 ' value='1870777'   \/><label for='answer-id-1870777' id='answer-label-1870777' class=' answer'><span>VMware vSAN should be the principal storage solution for the VCF Workload Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484322[]' id='answer-id-1870778' class='answer   answerof-484322 ' value='1870778'   \/><label for='answer-id-1870778' id='answer-label-1870778' class=' answer'><span>NFS v4.1 should be the principal storage solution for the VCF Management Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484322[]' id='answer-id-1870779' class='answer   answerof-484322 ' value='1870779'   \/><label for='answer-id-1870779' id='answer-label-1870779' class=' answer'><span>iSCSI should be the supplemental storage solution for the VCF Workload Domain.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484322[]' id='answer-id-1870780' class='answer   answerof-484322 ' value='1870780'   \/><label for='answer-id-1870780' id='answer-label-1870780' class=' answer'><span>VMware vSAN should be the principal storage solution for the VCF Management Domain.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-24' style=';'><div id='questionWrap-24'  class='   watupro-question-id-484323'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>24. <\/span>An administrator is tasked with replacing the existing Witness Host for a 2-node vSAN Edge Cluster. <br \/>\r<br>During the replacement procedure, the new Witness Host does not appear as an available selection. <br \/>\r<br>What is the cause of this configuration issue?<\/div><input type='hidden' name='question_id[]' id='qID_24' value='484323' \/><input type='hidden' id='answerType484323' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484323[]' id='answer-id-1870781' class='answer   answerof-484323 ' value='1870781'   \/><label for='answer-id-1870781' id='answer-label-1870781' class=' answer'><span>The VMkernel adapter is configured with vSAN traffic enabled.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484323[]' id='answer-id-1870782' class='answer   answerof-484323 ' value='1870782'   \/><label for='answer-id-1870782' id='answer-label-1870782' class=' answer'><span>The VMkernel adapter is connected to all hosts in the Stretched cluster.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484323[]' id='answer-id-1870783' class='answer   answerof-484323 ' value='1870783'   \/><label for='answer-id-1870783' id='answer-label-1870783' class=' answer'><span>The witness host resides in the 2-node vSAN enabled cluster.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-484323[]' id='answer-id-1870784' class='answer   answerof-484323 ' value='1870784'   \/><label for='answer-id-1870784' id='answer-label-1870784' class=' answer'><span>The witness host is already assigned to another 2-node vSAN cluster.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-25' style=';'><div id='questionWrap-25'  class='   watupro-question-id-484324'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>25. <\/span>A financial organization successfully deployed a new Workload Domain in VMware Cloud Foundation (VCF) using NFS storage. All ESX hosts are commissioned and connected to the same storage network. The system administrator is tasked to configure a new NFS datastore in the existing cluster. <br \/>\r<br>Which two steps are correct? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_25' value='484324' \/><input type='hidden' id='answerType484324' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484324[]' id='answer-id-1870785' class='answer   answerof-484324 ' value='1870785'   \/><label for='answer-id-1870785' id='answer-label-1870785' class=' answer'><span>Mount the NFS datastore on each ESX host in the cluster.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484324[]' id='answer-id-1870786' class='answer   answerof-484324 ' value='1870786'   \/><label for='answer-id-1870786' id='answer-label-1870786' class=' answer'><span>Attach NFS as a secondary datastore.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484324[]' id='answer-id-1870787' class='answer   answerof-484324 ' value='1870787'   \/><label for='answer-id-1870787' id='answer-label-1870787' class=' answer'><span>Create an NFS export on the storage array.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484324[]' id='answer-id-1870788' class='answer   answerof-484324 ' value='1870788'   \/><label for='answer-id-1870788' id='answer-label-1870788' class=' answer'><span>Configure vSAN on all hosts.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-484324[]' id='answer-id-1870789' class='answer   answerof-484324 ' value='1870789'   \/><label for='answer-id-1870789' id='answer-label-1870789' class=' answer'><span>Mount the NFS datastore on one ESX host in the cluster.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div style='display:none' id='question-26'>\n\t<div class='question-content'>\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\" alt=\"Loading...\" title=\"Loading...\" \/>&nbsp;Loading...\t<\/div>\n<\/div>\n\n<br \/>\n\t\n\t\t\t<div class=\"watupro_buttons flex \" id=\"watuPROButtons12437\" >\n\t\t  <div id=\"prev-question\" style=\"display:none;\"><input type=\"button\" value=\"&lt; Previous\" onclick=\"WatuPRO.nextQuestion(event, 'previous');\"\/><\/div>\t\t  \t\t  \t\t   \n\t\t   \t  \t\t<div><input type=\"button\" name=\"action\" class=\"watupro-submit-button\" onclick=\"WatuPRO.submitResult(event)\" id=\"action-button\" value=\"View Results\"  \/>\n\t\t<\/div>\n\t\t<\/div>\n\t\t\n\t<input type=\"hidden\" name=\"quiz_id\" value=\"12437\" id=\"watuPROExamID\"\/>\n\t<input type=\"hidden\" name=\"start_time\" id=\"startTime\" value=\"2026-05-25 12:04:51\" \/>\n\t<input type=\"hidden\" name=\"start_timestamp\" id=\"startTimeStamp\" value=\"1779710691\" \/>\n\t<input type=\"hidden\" name=\"question_ids\" value=\"\" \/>\n\t<input type=\"hidden\" name=\"watupro_questions\" value=\"484300:1870695,1870696,1870697,1870698,1870699 | 484301:1870700,1870701,1870702,1870703 | 484302:1870704,1870705,1870706,1870707,1870708 | 484303:1870709,1870710,1870711,1870712,1870713 | 484304:1870714,1870715,1870716,1870717 | 484305:1870718,1870719,1870720,1870721,1870722,1870723 | 484306:1870724 | 484307:1870725 | 484308:1870726,1870727,1870728,1870729 | 484309:1870730 | 484310:1870731,1870732,1870733,1870734 | 484311:1870735,1870736,1870737,1870738 | 484312:1870739 | 484313:1870740,1870741,1870742,1870743 | 484314:1870744,1870745,1870746,1870747 | 484315:1870748,1870749,1870750,1870751 | 484316:1870752,1870753,1870754,1870755 | 484317:1870756,1870757,1870758,1870759 | 484318:1870760,1870761,1870762,1870763 | 484319:1870764 | 484320:1870765,1870766,1870767,1870768,1870769,1870770 | 484321:1870771,1870772,1870773,1870774 | 484322:1870775,1870776,1870777,1870778,1870779,1870780 | 484323:1870781,1870782,1870783,1870784 | 484324:1870785,1870786,1870787,1870788,1870789\" \/>\n\t<input type=\"hidden\" name=\"no_ajax\" value=\"0\">\t\t\t<\/form>\n\t<p>&nbsp;<\/p>\n<\/div>\n\n<script type=\"text\/javascript\">\n\/\/jQuery(document).ready(function(){\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \t\nvar question_ids = \"484300,484301,484302,484303,484304,484305,484306,484307,484308,484309,484310,484311,484312,484313,484314,484315,484316,484317,484318,484319,484320,484321,484322,484323,484324\";\nWatuPROSettings[12437] = {};\nWatuPRO.qArr = question_ids.split(',');\nWatuPRO.exam_id = 12437;\t    \nWatuPRO.post_id = 127806;\nWatuPRO.store_progress = 0;\nWatuPRO.curCatPage = 1;\nWatuPRO.requiredIDs=\"0\".split(\",\");\nWatuPRO.hAppID = \"0.89838000 1779710691\";\nvar url = \"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/show_exam.php\";\nWatuPRO.examMode = 1;\nWatuPRO.siteURL=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-admin\/admin-ajax.php\";\nWatuPRO.emailIsNotRequired = 0;\nWatuPROIntel.init(12437);\nWatuPRO.inCategoryPages=1;});    \t \n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>You are eager to pass the Advanced VMware Cloud Foundation 9.0 Storage (3V0-23.25) exam successfully, so you can come to DumpsBase to download the most updated dumps. The 3V0-23.25 dumps (V11.02) are available with 80 real exam questions, ensuring that you practice these questions to pass your Advanced VMware Cloud Foundation 9.0 Storage certification exam. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[114],"tags":[20841,21217],"class_list":["post-127806","post","type-post","status-publish","format-standard","hentry","category-vmware","tag-3v0-23-25","tag-3v0-23-25-dumps"],"_links":{"self":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/127806","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/comments?post=127806"}],"version-history":[{"count":1,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/127806\/revisions"}],"predecessor-version":[{"id":127807,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/127806\/revisions\/127807"}],"wp:attachment":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/media?parent=127806"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/categories?post=127806"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/tags?post=127806"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}