{"id":112389,"date":"2025-10-22T03:23:47","date_gmt":"2025-10-22T03:23:47","guid":{"rendered":"https:\/\/www.dumpsbase.com\/freedumps\/?p=112389"},"modified":"2025-10-22T03:23:47","modified_gmt":"2025-10-22T03:23:47","slug":"dell-d-pe-oe-23-dumps-v9-02-are-your-reliable-study-materials-to-pass-continue-to-check-the-d-pe-oe-23-free-dumps-part-3-q81-q120","status":"publish","type":"post","link":"https:\/\/www.dumpsbase.com\/freedumps\/dell-d-pe-oe-23-dumps-v9-02-are-your-reliable-study-materials-to-pass-continue-to-check-the-d-pe-oe-23-free-dumps-part-3-q81-q120.html","title":{"rendered":"Dell D-PE-OE-23 Dumps (V9.02) Are Your Reliable Study Materials to Pass: Continue to Check the D-PE-OE-23 Free Dumps (Part 3, Q81-Q120)"},"content":{"rendered":"<p>DumpsBase offers Dell D-PE-OE-23 dumps (V9.02) to be your reliable study materials, which help you pass the Dell Technologies PowerEdge Operate 2023 exam on the first attempt. The dumps contain real questions and verified answers with a 100% success guarantee, making your exam pass smoother. If you want to check the quality of the dumps, you can read our free dumps first:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.dumpsbase.com\/freedumps\/dell-d-pe-oe-23-dumps-updated-choose-d-pe-oe-23-dumps-v9-02-to-prepare-and-read-d-pe-oe-23-free-dumps-part-1-q1-q40-today-to-verify.html\"><em>D-PE-OE-23 free dumps (Part 1, Q1-Q40) of V9.02<\/em><\/a><\/li>\n<li><a href=\"https:\/\/www.dumpsbase.com\/freedumps\/smarter-dell-technologies-poweredge-operate-2023-exam-preparation-starts-here-read-d-pe-oe-23-free-dumps-part-2-q41-q80-of-v9-02-first.html\"><em>D-PE-OE-23 free dumps (Part 2, Q41-Q80) of V9.02<\/em><\/a><\/li>\n<\/ul>\n<p>After reading all these sample questions, you can trust, our D-PE-OE-23 dumps (V9.02) will ensure that your exam preparation is effective. Choose DumpsBase and prepare for your Dell Technologies PowerEdge Operate 2023 D-PE-OE-23 exam confidently. Continue to focus on DumpsBase; we will share more demos today.<\/p>\n<p><!-- notionvc: dafe35a7-3e7f-4741-8565-d7e034b12ca0 --><\/p>\n<h2>Below are the <span style=\"background-color: #00ff00;\"><em>Dell D-PE-OE-23 free dumps (Part 3, Q81-Q120) of V9.02<\/em><\/span> that can be continued to read:<\/h2>\n<script>\n\t  window.fbAsyncInit = function() {\n\t    FB.init({\n\t      appId            : '622169541470367',\n\t      autoLogAppEvents : true,\n\t      xfbml            : true,\n\t      version          : 'v3.1'\n\t    });\n\t  };\n\t\n\t  (function(d, s, id){\n\t     var js, fjs = d.getElementsByTagName(s)[0];\n\t     if (d.getElementById(id)) {return;}\n\t     js = d.createElement(s); js.id = id;\n\t     js.src = \"https:\/\/connect.facebook.net\/en_US\/sdk.js\";\n\t     fjs.parentNode.insertBefore(js, fjs);\n\t   }(document, 'script', 'facebook-jssdk'));\n\t<\/script><script type=\"text\/javascript\" >\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \nif(!window.jQuery) alert(\"The important jQuery library is not properly loaded in your site. Your WordPress theme is probably missing the essential wp_head() call. You can switch to another theme and you will see that the plugin works fine and this notice disappears. If you are still not sure what to do you can contact us for help.\");\n});\n<\/script>  \n  \n<div  id=\"watupro_quiz\" class=\"quiz-area single-page-quiz\">\n<p id=\"submittingExam9812\" style=\"display:none;text-align:center;\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\"><\/p>\n\n<div class=\"watupro-exam-description\" id=\"description-quiz-9812\"><\/div>\n\n<form action=\"\" method=\"post\" class=\"quiz-form\" id=\"quiz-9812\"  enctype=\"multipart\/form-data\" >\n<div class='watu-question ' id='question-1' style=';'><div id='questionWrap-1'  class='   watupro-question-id-391364'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>1. <\/span>What type of screwdriver is required to remove the processor heat sink module?<\/div><input type='hidden' name='question_id[]' id='qID_1' value='391364' \/><input type='hidden' id='answerType391364' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391364[]' id='answer-id-1521833' class='answer   answerof-391364 ' value='1521833'   \/><label for='answer-id-1521833' id='answer-label-1521833' class=' answer'><span>Torx<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391364[]' id='answer-id-1521834' class='answer   answerof-391364 ' value='1521834'   \/><label for='answer-id-1521834' id='answer-label-1521834' class=' answer'><span>Hex<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391364[]' id='answer-id-1521835' class='answer   answerof-391364 ' value='1521835'   \/><label for='answer-id-1521835' id='answer-label-1521835' class=' answer'><span>Phillips<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391364[]' id='answer-id-1521836' class='answer   answerof-391364 ' value='1521836'   \/><label for='answer-id-1521836' id='answer-label-1521836' class=' answer'><span>Torque<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-2' style=';'><div id='questionWrap-2'  class='   watupro-question-id-391365'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>2. <\/span>An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings. <br \/>\r<br>What should the engineer do to complete the task?<\/div><input type='hidden' name='question_id[]' id='qID_2' value='391365' \/><input type='hidden' id='answerType391365' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391365[]' id='answer-id-1521837' class='answer   answerof-391365 ' value='1521837'   \/><label for='answer-id-1521837' id='answer-label-1521837' class=' answer'><span>Configure the PowerEdge R440 PSU with 1+1 configuration<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391365[]' id='answer-id-1521838' class='answer   answerof-391365 ' value='1521838'   \/><label for='answer-id-1521838' id='answer-label-1521838' class=' answer'><span>Order a new PSU specific to the existing PowerEdge R440<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391365[]' id='answer-id-1521839' class='answer   answerof-391365 ' value='1521839'   \/><label for='answer-id-1521839' id='answer-label-1521839' class=' answer'><span>Add the PowerEdge R420 PSU modules to the PowerEdge R440<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391365[]' id='answer-id-1521840' class='answer   answerof-391365 ' value='1521840'   \/><label for='answer-id-1521840' id='answer-label-1521840' class=' answer'><span>Add the PowerEdge R430 PSU modules to the PowerEdge R440<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-3' style=';'><div id='questionWrap-3'  class='   watupro-question-id-391366'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>3. <\/span>A server administrator needs to access the iDRAC8 default interface. They are not using DHCP. They open a web browser and prepare to enter an IP address. <br \/>\r<br>What IP address should they use?<\/div><input type='hidden' name='question_id[]' id='qID_3' value='391366' \/><input type='hidden' id='answerType391366' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391366[]' id='answer-id-1521841' class='answer   answerof-391366 ' value='1521841'   \/><label for='answer-id-1521841' id='answer-label-1521841' class=' answer'><span>https:\/\/192.168.120.1<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391366[]' id='answer-id-1521842' class='answer   answerof-391366 ' value='1521842'   \/><label for='answer-id-1521842' id='answer-label-1521842' class=' answer'><span>https:\/\/192.168.0.120<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391366[]' id='answer-id-1521843' class='answer   answerof-391366 ' value='1521843'   \/><label for='answer-id-1521843' id='answer-label-1521843' class=' answer'><span>https:\/\/192.168.1.120<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391366[]' id='answer-id-1521844' class='answer   answerof-391366 ' value='1521844'   \/><label for='answer-id-1521844' id='answer-label-1521844' class=' answer'><span>https:\/\/10.195.2.120<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-4' style=';'><div id='questionWrap-4'  class='   watupro-question-id-391367'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>4. <\/span>A technician needs to install the OS on a server remotely using iDRAC. <br \/>\r<br>What is the minimum iDRAC license required to perform this task?<\/div><input type='hidden' name='question_id[]' id='qID_4' value='391367' \/><input type='hidden' id='answerType391367' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391367[]' id='answer-id-1521845' class='answer   answerof-391367 ' value='1521845'   \/><label for='answer-id-1521845' id='answer-label-1521845' class=' answer'><span>Express<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391367[]' id='answer-id-1521846' class='answer   answerof-391367 ' value='1521846'   \/><label for='answer-id-1521846' id='answer-label-1521846' class=' answer'><span>Enterprise<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391367[]' id='answer-id-1521847' class='answer   answerof-391367 ' value='1521847'   \/><label for='answer-id-1521847' id='answer-label-1521847' class=' answer'><span>Basic<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391367[]' id='answer-id-1521848' class='answer   answerof-391367 ' value='1521848'   \/><label for='answer-id-1521848' id='answer-label-1521848' class=' answer'><span>Baseboard Management Controller<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-5' style=';'><div id='questionWrap-5'  class='   watupro-question-id-391368'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>5. <\/span>A technician needs to configure the Lifecycle Controller network settings with a static IP address. A limited number of static IP addresses are available for use. <br \/>\r<br>Which previously assigned IP address can also be used for the Lifecycle Controller?<\/div><input type='hidden' name='question_id[]' id='qID_5' value='391368' \/><input type='hidden' id='answerType391368' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391368[]' id='answer-id-1521849' class='answer   answerof-391368 ' value='1521849'   \/><label for='answer-id-1521849' id='answer-label-1521849' class=' answer'><span>The host operating system\u2019s IP address<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391368[]' id='answer-id-1521850' class='answer   answerof-391368 ' value='1521850'   \/><label for='answer-id-1521850' id='answer-label-1521850' class=' answer'><span>The iDRAC IP address<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391368[]' id='answer-id-1521851' class='answer   answerof-391368 ' value='1521851'   \/><label for='answer-id-1521851' id='answer-label-1521851' class=' answer'><span>The IP address of a different server on the network<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391368[]' id='answer-id-1521852' class='answer   answerof-391368 ' value='1521852'   \/><label for='answer-id-1521852' id='answer-label-1521852' class=' answer'><span>The default gateway IP address<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-6' style=';'><div id='questionWrap-6'  class='   watupro-question-id-391369'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>6. <\/span>Which memory operation modes are supported for a Dell PowerEdge R660?<\/div><input type='hidden' name='question_id[]' id='qID_6' value='391369' \/><input type='hidden' id='answerType391369' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391369[]' id='answer-id-1521853' class='answer   answerof-391369 ' value='1521853'   \/><label for='answer-id-1521853' id='answer-label-1521853' class=' answer'><span>Optimizer and Persistent Memory<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391369[]' id='answer-id-1521854' class='answer   answerof-391369 ' value='1521854'   \/><label for='answer-id-1521854' id='answer-label-1521854' class=' answer'><span>Optimizer and Dell Default Resilient<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391369[]' id='answer-id-1521855' class='answer   answerof-391369 ' value='1521855'   \/><label for='answer-id-1521855' id='answer-label-1521855' class=' answer'><span>Optimizer and Mirror<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391369[]' id='answer-id-1521856' class='answer   answerof-391369 ' value='1521856'   \/><label for='answer-id-1521856' id='answer-label-1521856' class=' answer'><span>Dell Default Resilient and Mirror<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-7' style=';'><div id='questionWrap-7'  class='   watupro-question-id-391370'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>7. <\/span>A technician has a 13G system that is giving NO video to a crash cart connected to the front VGA port. The LCD is NOT reporting any errors. <br \/>\r<br>The system reports \u2018CPU Resetting\u2019 messages sporadically in the lifecycle log. The iDRAC runs an Express license. The technician needs to most efficiently determine if the system is completing POST despite the video issue. <br \/>\r<br>Which two steps should the technician take to perform this task? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_7' value='391370' \/><input type='hidden' id='answerType391370' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391370[]' id='answer-id-1521857' class='answer   answerof-391370 ' value='1521857'   \/><label for='answer-id-1521857' id='answer-label-1521857' class=' answer'><span>Reduce to minimum to post<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391370[]' id='answer-id-1521858' class='answer   answerof-391370 ' value='1521858'   \/><label for='answer-id-1521858' id='answer-label-1521858' class=' answer'><span>Launch the iDRAC virtual console<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391370[]' id='answer-id-1521859' class='answer   answerof-391370 ' value='1521859'   \/><label for='answer-id-1521859' id='answer-label-1521859' class=' answer'><span>Connect to rear VGA port<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391370[]' id='answer-id-1521860' class='answer   answerof-391370 ' value='1521860'   \/><label for='answer-id-1521860' id='answer-label-1521860' class=' answer'><span>Hold the system identification button for 6 seconds<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-8' style=';'><div id='questionWrap-8'  class='   watupro-question-id-391371'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>8. <\/span>A Dell EMC PowerEdge 13G server is being controlled through a secure port by iDRAC8. <br \/>\r<br>What login connection options are available on server using a secure port?<\/div><input type='hidden' name='question_id[]' id='qID_8' value='391371' \/><input type='hidden' id='answerType391371' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391371[]' id='answer-id-1521861' class='answer   answerof-391371 ' value='1521861'   \/><label for='answer-id-1521861' id='answer-label-1521861' class=' answer'><span>DRM only<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391371[]' id='answer-id-1521862' class='answer   answerof-391371 ' value='1521862'   \/><label for='answer-id-1521862' id='answer-label-1521862' class=' answer'><span>RACADM CLI and DRM<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391371[]' id='answer-id-1521863' class='answer   answerof-391371 ' value='1521863'   \/><label for='answer-id-1521863' id='answer-label-1521863' class=' answer'><span>Web GUI and RACADM CLI<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391371[]' id='answer-id-1521864' class='answer   answerof-391371 ' value='1521864'   \/><label for='answer-id-1521864' id='answer-label-1521864' class=' answer'><span>Web GUI and SSH<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-9' style=';'><div id='questionWrap-9'  class='   watupro-question-id-391372'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>9. <\/span>A technician needs to analyze a server that is using more power than expected. The server is part of a cluster that runs jobs between 8 AM and 5 PM. The cluster is not used at other times of the day. The server runs an unsupported OS. Performance while jobs are running is a key consideration. <br \/>\r<br>Which option should the technician choose from within System Profile Settings within System Setup to address this issue?<\/div><input type='hidden' name='question_id[]' id='qID_9' value='391372' \/><input type='hidden' id='answerType391372' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391372[]' id='answer-id-1521865' class='answer   answerof-391372 ' value='1521865'   \/><label for='answer-id-1521865' id='answer-label-1521865' class=' answer'><span>Dense Configuration<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391372[]' id='answer-id-1521866' class='answer   answerof-391372 ' value='1521866'   \/><label for='answer-id-1521866' id='answer-label-1521866' class=' answer'><span>Performance Per Watt (DAPC)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391372[]' id='answer-id-1521867' class='answer   answerof-391372 ' value='1521867'   \/><label for='answer-id-1521867' id='answer-label-1521867' class=' answer'><span>Performance<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391372[]' id='answer-id-1521868' class='answer   answerof-391372 ' value='1521868'   \/><label for='answer-id-1521868' id='answer-label-1521868' class=' answer'><span>Performance Per Watt (OS)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-10' style=';'><div id='questionWrap-10'  class='   watupro-question-id-391373'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>10. <\/span>Case Study 1 <br \/>\r<br>A company has several independent business units that operate globally. The company has consolidated its IT infrastructure services and operations. Common infrastructural services which include IPAM, DNS, NTP, DHCP, and SMTP have been consolidated. <br \/>\r<br>The company has complimented its infrastructure development by investing in Dell EMC Isilon clusters to host its user's home and group directories and for compliance archival purposes required by individual business units. The IT operations are located in India and the United States with its primary data center facilities co-located between New York and Texas. <br \/>\r<br>The company has a total of 60 AD forests: <br \/>\r<br>- 1 main domain <br \/>\r<br>- 55 domains have one-way trust relationships with the main domain <br \/>\r<br>- An additional 4 domains do not have any trust relationship with no future plans of establishing trust relationships with the other domains. <br \/>\r<br>Users of different AD domains use different FQDN to access their corresponding file services. Additionally, the company does not plan to consolidate the AD domains and each domain uses a different IP subnet. <br \/>\r<br>The users of the domains with no trust relationships have a compliance archival requirement. The company wants to all data to be replicated between New York and Texas. <br \/>\r<br>How many tenant Access zones will be required?<\/div><input type='hidden' name='question_id[]' id='qID_10' value='391373' \/><input type='hidden' id='answerType391373' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391373[]' id='answer-id-1521869' class='answer   answerof-391373 ' value='1521869'   \/><label for='answer-id-1521869' id='answer-label-1521869' class=' answer'><span>1<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391373[]' id='answer-id-1521870' class='answer   answerof-391373 ' value='1521870'   \/><label for='answer-id-1521870' id='answer-label-1521870' class=' answer'><span>55<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391373[]' id='answer-id-1521871' class='answer   answerof-391373 ' value='1521871'   \/><label for='answer-id-1521871' id='answer-label-1521871' class=' answer'><span>59<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391373[]' id='answer-id-1521872' class='answer   answerof-391373 ' value='1521872'   \/><label for='answer-id-1521872' id='answer-label-1521872' class=' answer'><span>60<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-11' style=';'><div id='questionWrap-11'  class='   watupro-question-id-391374'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>11. <\/span>A technician needs to update the iDRAC license on a PowerEdge R740 server from Express to Enterprise. <br \/>\r<br>The server has the following components: <br \/>\r<br>- 2x CPUs <br \/>\r<br>- 384 GB RAM <br \/>\r<br>- 6x 1 TB drives <br \/>\r<br>- 1x PSU <br \/>\r<br>The server is powered down but connected to active AC. The user wants it to stay powered down and not connect to any networks. No errors are presently displayed. <br \/>\r<br>How can the technician upgrade the license?<\/div><input type='hidden' name='question_id[]' id='qID_11' value='391374' \/><input type='hidden' id='answerType391374' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391374[]' id='answer-id-1521873' class='answer   answerof-391374 ' value='1521873'   \/><label for='answer-id-1521873' id='answer-label-1521873' class=' answer'><span>The license cannot be upgraded because the user will not allow the server to be powered on<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391374[]' id='answer-id-1521874' class='answer   answerof-391374 ' value='1521874'   \/><label for='answer-id-1521874' id='answer-label-1521874' class=' answer'><span>The license cannot be upgraded on a single PSU system<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391374[]' id='answer-id-1521875' class='answer   answerof-391374 ' value='1521875'   \/><label for='answer-id-1521875' id='answer-label-1521875' class=' answer'><span>Power on the server then connect to the iDRAC and upgrade iDRAC license before powering the server down<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391374[]' id='answer-id-1521876' class='answer   answerof-391374 ' value='1521876'   \/><label for='answer-id-1521876' id='answer-label-1521876' class=' answer'><span>Connect to the iDRAC GUI and upgrade the iDRAC license while the server is powered down.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-12' style=';'><div id='questionWrap-12'  class='   watupro-question-id-391375'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>12. <\/span>Where is the data stored to allow Easy Restore to successfully complete a system board replacement?<\/div><input type='hidden' name='question_id[]' id='qID_12' value='391375' \/><input type='hidden' id='answerType391375' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391375[]' id='answer-id-1521877' class='answer   answerof-391375 ' value='1521877'   \/><label for='answer-id-1521877' id='answer-label-1521877' class=' answer'><span>NAND Flash module on the disk drive mid plane<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391375[]' id='answer-id-1521878' class='answer   answerof-391375 ' value='1521878'   \/><label for='answer-id-1521878' id='answer-label-1521878' class=' answer'><span>IDSDM SD card<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391375[]' id='answer-id-1521879' class='answer   answerof-391375 ' value='1521879'   \/><label for='answer-id-1521879' id='answer-label-1521879' class=' answer'><span>vFlash SD card<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391375[]' id='answer-id-1521880' class='answer   answerof-391375 ' value='1521880'   \/><label for='answer-id-1521880' id='answer-label-1521880' class=' answer'><span>Serial Flash storage in the server\u2019s front panel<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-13' style=';'><div id='questionWrap-13'  class='   watupro-question-id-391376'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>13. <\/span>Beginning with which generation Dell EMC PowerEdge server is the NDC available?<\/div><input type='hidden' name='question_id[]' id='qID_13' value='391376' \/><input type='hidden' id='answerType391376' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391376[]' id='answer-id-1521881' class='answer   answerof-391376 ' value='1521881'   \/><label for='answer-id-1521881' id='answer-label-1521881' class=' answer'><span>11G<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391376[]' id='answer-id-1521882' class='answer   answerof-391376 ' value='1521882'   \/><label for='answer-id-1521882' id='answer-label-1521882' class=' answer'><span>12G<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391376[]' id='answer-id-1521883' class='answer   answerof-391376 ' value='1521883'   \/><label for='answer-id-1521883' id='answer-label-1521883' class=' answer'><span>13G<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391376[]' id='answer-id-1521884' class='answer   answerof-391376 ' value='1521884'   \/><label for='answer-id-1521884' id='answer-label-1521884' class=' answer'><span>14G<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-14' style=';'><div id='questionWrap-14'  class='   watupro-question-id-391377'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>14. <\/span>A user installed OME on a PowerEdge R640 server. OME has discovered and is currently monitoring another 30 remote PowerEdge 14G servers. <br \/>\r<br>Each server has the following configuration: <br \/>\r<br>- 2x CPUs <br \/>\r<br>- 384 GB RAM <br \/>\r<br>- 6x 1TB drives in a RAID 6 virtual disk <br \/>\r<br>- No hot spare drive <br \/>\r<br>- PERC <br \/>\r<br>- vFlash <br \/>\r<br>- iDRAC9 Express license <br \/>\r<br>At 9 PM on Monday evening, one of the remote servers has a disk failure but stays operational. The administrator monitoring OME does not find out about the issue until 5 PM in the following Friday. They place a support call to investigate why OME was not informed about the disk failure before then. <br \/>\r<br>What is the reason for this issue not being reported to OME?<\/div><input type='hidden' name='question_id[]' id='qID_14' value='391377' \/><input type='hidden' id='answerType391377' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391377[]' id='answer-id-1521885' class='answer   answerof-391377 ' value='1521885'   \/><label for='answer-id-1521885' id='answer-label-1521885' class=' answer'><span>Remote servers are not configured with OME as the trap destination address. OME discovered the issue during a routing status check which is configured to run at 5 PM every Friday.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391377[]' id='answer-id-1521886' class='answer   answerof-391377 ' value='1521886'   \/><label for='answer-id-1521886' id='answer-label-1521886' class=' answer'><span>OME only updates its alert database at 5 PM every Friday.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391377[]' id='answer-id-1521887' class='answer   answerof-391377 ' value='1521887'   \/><label for='answer-id-1521887' id='answer-label-1521887' class=' answer'><span>Remote servers are not configured with OME as the trap destination address. OME was informed of the issue when remote servers sent alerts at 5 PM Friday.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391377[]' id='answer-id-1521888' class='answer   answerof-391377 ' value='1521888'   \/><label for='answer-id-1521888' id='answer-label-1521888' class=' answer'><span>Remote servers need to have the iDRAC Enterprise license installed to be able to send alerts.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-15' style=';'><div id='questionWrap-15'  class='   watupro-question-id-391378'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>15. <\/span>Which sections are included in the iDRAC Troubleshooting tab?<\/div><input type='hidden' name='question_id[]' id='qID_15' value='391378' \/><input type='hidden' id='answerType391378' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391378[]' id='answer-id-1521889' class='answer   answerof-391378 ' value='1521889'   \/><label for='answer-id-1521889' id='answer-label-1521889' class=' answer'><span>Post Code, Diagnostics, and Video capture<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391378[]' id='answer-id-1521890' class='answer   answerof-391378 ' value='1521890'   \/><label for='answer-id-1521890' id='answer-label-1521890' class=' answer'><span>Diagnostics, Last crash screen, and Post Code<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391378[]' id='answer-id-1521891' class='answer   answerof-391378 ' value='1521891'   \/><label for='answer-id-1521891' id='answer-label-1521891' class=' answer'><span>Video capture, Post Code, and Last crash screen<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391378[]' id='answer-id-1521892' class='answer   answerof-391378 ' value='1521892'   \/><label for='answer-id-1521892' id='answer-label-1521892' class=' answer'><span>Last crash screen, Video capture, and, Diagnostics<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-16' style=';'><div id='questionWrap-16'  class='   watupro-question-id-391379'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>16. <\/span>A technician is creating a virtual disk in the DRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016. They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard. Only the first 2048 GB on the virtual disk can be partitioned. <br \/>\r<br>How should the technician obtain access to the remaining 2 TB (approximately) of storage?<\/div><input type='hidden' name='question_id[]' id='qID_16' value='391379' \/><input type='hidden' id='answerType391379' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391379[]' id='answer-id-1521893' class='answer   answerof-391379 ' value='1521893'   \/><label for='answer-id-1521893' id='answer-label-1521893' class=' answer'><span>Delete the 4 TB virtual disk and create a virtual (boot) disk no longer than 2048 G<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391379[]' id='answer-id-1521894' class='answer   answerof-391379 ' value='1521894'   \/><label for='answer-id-1521894' id='answer-label-1521894' class=' answer'><span>Upgrade to a newer version of the operating system.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391379[]' id='answer-id-1521895' class='answer   answerof-391379 ' value='1521895'   \/><label for='answer-id-1521895' id='answer-label-1521895' class=' answer'><span>Use the lifecycle Controller\u2019s OS Deployment Wizard to deploy the OS on this server.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391379[]' id='answer-id-1521896' class='answer   answerof-391379 ' value='1521896'   \/><label for='answer-id-1521896' id='answer-label-1521896' class=' answer'><span>Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-17' style=';'><div id='questionWrap-17'  class='   watupro-question-id-391380'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>17. <\/span>Refer to the exhibit. <br \/>\r<br><br><img decoding=\"async\" width=470 height=101 id=\"\u56fe\u7247 1\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2025\/04\/image008-7.jpg\"><br><br \/>\r<br>A technician tries to apply a BIOS update through the iDRAC web interface on a server using the Linux Dell Update Package file BIOS_2H4CC_LN_2 0.2.BIN. The error shown occurs. <br \/>\r<br>How should this error be fixed?<\/div><input type='hidden' name='question_id[]' id='qID_17' value='391380' \/><input type='hidden' id='answerType391380' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391380[]' id='answer-id-1521897' class='answer   answerof-391380 ' value='1521897'   \/><label for='answer-id-1521897' id='answer-label-1521897' class=' answer'><span>Download and apply the Windows Dell Update Package file<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391380[]' id='answer-id-1521898' class='answer   answerof-391380 ' value='1521898'   \/><label for='answer-id-1521898' id='answer-label-1521898' class=' answer'><span>Extract the Linux Dell Update Package and apply payload file<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391380[]' id='answer-id-1521899' class='answer   answerof-391380 ' value='1521899'   \/><label for='answer-id-1521899' id='answer-label-1521899' class=' answer'><span>Redownload the file to replace corrupted version and reinstall<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391380[]' id='answer-id-1521900' class='answer   answerof-391380 ' value='1521900'   \/><label for='answer-id-1521900' id='answer-label-1521900' class=' answer'><span>Reset the iDRAC and reapply the update<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-18' style=';'><div id='questionWrap-18'  class='   watupro-question-id-391381'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>18. <\/span>A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights-out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials. <br \/>\r<br>How could the technician change the iDRAC password?<\/div><input type='hidden' name='question_id[]' id='qID_18' value='391381' \/><input type='hidden' id='answerType391381' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391381[]' id='answer-id-1521901' class='answer   answerof-391381 ' value='1521901'   \/><label for='answer-id-1521901' id='answer-label-1521901' class=' answer'><span>SupportAssist Enterprise<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391381[]' id='answer-id-1521902' class='answer   answerof-391381 ' value='1521902'   \/><label for='answer-id-1521902' id='answer-label-1521902' class=' answer'><span>iDRAC Web GUI<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391381[]' id='answer-id-1521903' class='answer   answerof-391381 ' value='1521903'   \/><label for='answer-id-1521903' id='answer-label-1521903' class=' answer'><span>OpenManage Server Administrator<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391381[]' id='answer-id-1521904' class='answer   answerof-391381 ' value='1521904'   \/><label for='answer-id-1521904' id='answer-label-1521904' class=' answer'><span>Virtual Console; press F2 after rebooting system<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-19' style=';'><div id='questionWrap-19'  class='   watupro-question-id-391382'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>19. <\/span>A server is configured in a 1+1 power configuration with both PSUs connected to a single PDU. <br \/>\r<br>Which redundancy options does this configuration supply?<\/div><input type='hidden' name='question_id[]' id='qID_19' value='391382' \/><input type='hidden' id='answerType391382' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391382[]' id='answer-id-1521905' class='answer   answerof-391382 ' value='1521905'   \/><label for='answer-id-1521905' id='answer-label-1521905' class=' answer'><span>PSU redundancy only<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391382[]' id='answer-id-1521906' class='answer   answerof-391382 ' value='1521906'   \/><label for='answer-id-1521906' id='answer-label-1521906' class=' answer'><span>PSU redundancy and PDU redundancy<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391382[]' id='answer-id-1521907' class='answer   answerof-391382 ' value='1521907'   \/><label for='answer-id-1521907' id='answer-label-1521907' class=' answer'><span>No redundancy unless each PSU is connected to a separate PDU<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391382[]' id='answer-id-1521908' class='answer   answerof-391382 ' value='1521908'   \/><label for='answer-id-1521908' id='answer-label-1521908' class=' answer'><span>PSU redundancy and Grid redundancy<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-20' style=';'><div id='questionWrap-20'  class='   watupro-question-id-391383'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>20. <\/span>Which two tools provide a user interface to manage the Boot Optimized Storage Solution (BOSS) cards? (Select 2)<\/div><input type='hidden' name='question_id[]' id='qID_20' value='391383' \/><input type='hidden' id='answerType391383' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391383[]' id='answer-id-1521909' class='answer   answerof-391383 ' value='1521909'   \/><label for='answer-id-1521909' id='answer-label-1521909' class=' answer'><span>OpenManage Mobile (OMM)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391383[]' id='answer-id-1521910' class='answer   answerof-391383 ' value='1521910'   \/><label for='answer-id-1521910' id='answer-label-1521910' class=' answer'><span>Intelligent Platform Management Interface Tool (IPMITool)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391383[]' id='answer-id-1521911' class='answer   answerof-391383 ' value='1521911'   \/><label for='answer-id-1521911' id='answer-label-1521911' class=' answer'><span>Integrated Dell Remote Access Controller (iDRAC)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391383[]' id='answer-id-1521912' class='answer   answerof-391383 ' value='1521912'   \/><label for='answer-id-1521912' id='answer-label-1521912' class=' answer'><span>OpenManage Server Administrator (OMSA)<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391383[]' id='answer-id-1521913' class='answer   answerof-391383 ' value='1521913'   \/><label for='answer-id-1521913' id='answer-label-1521913' class=' answer'><span>Remote Access Controller Admin (RACADM)<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-21' style=';'><div id='questionWrap-21'  class='   watupro-question-id-391384'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>21. <\/span>A technician needs to remotely update the iDRAC with Lifecycle Controller firmware. They have downloaded the latest iDRAC firmware to the management station and connected to the iDRAC GUI. <br \/>\r<br>What step is required to complete the update?<\/div><input type='hidden' name='question_id[]' id='qID_21' value='391384' \/><input type='hidden' id='answerType391384' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391384[]' id='answer-id-1521914' class='answer   answerof-391384 ' value='1521914'   \/><label for='answer-id-1521914' id='answer-label-1521914' class=' answer'><span>Go to the Summary Page and reset the iDRAC<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391384[]' id='answer-id-1521915' class='answer   answerof-391384 ' value='1521915'   \/><label for='answer-id-1521915' id='answer-label-1521915' class=' answer'><span>Boot into the OS via Virtual Console and execute the firmware<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391384[]' id='answer-id-1521916' class='answer   answerof-391384 ' value='1521916'   \/><label for='answer-id-1521916' id='answer-label-1521916' class=' answer'><span>Go to the Firmware Update page and upload the iDRAC firmware<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391384[]' id='answer-id-1521917' class='answer   answerof-391384 ' value='1521917'   \/><label for='answer-id-1521917' id='answer-label-1521917' class=' answer'><span>Boot the server into F10 to start the firmware update<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-22' style=';'><div id='questionWrap-22'  class='   watupro-question-id-391385'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>22. <\/span>Case Study 3 <br \/>\r<br>A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance. <br \/>\r<br>However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features. <br \/>\r<br>The compute and storage environment consists of the following: <br \/>\r<br>- 200 TB of Fibre Channel drives on NetApp ONTAP 7 <br \/>\r<br>- Environment is expected to grow 200 TB over the next three years <br \/>\r<br>Which combined solution addresses the company's requirement for D@RE and U.S.SEC 17a-4(f)?<\/div><input type='hidden' name='question_id[]' id='qID_22' value='391385' \/><input type='hidden' id='answerType391385' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391385[]' id='answer-id-1521918' class='answer   answerof-391385 ' value='1521918'   \/><label for='answer-id-1521918' id='answer-label-1521918' class=' answer'><span>All Flash and SmartLock Compliance mode<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391385[]' id='answer-id-1521919' class='answer   answerof-391385 ' value='1521919'   \/><label for='answer-id-1521919' id='answer-label-1521919' class=' answer'><span>SmartLock Enterprise mode and STIG<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391385[]' id='answer-id-1521920' class='answer   answerof-391385 ' value='1521920'   \/><label for='answer-id-1521920' id='answer-label-1521920' class=' answer'><span>SED and SmartLock Enterprise mode<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391385[]' id='answer-id-1521921' class='answer   answerof-391385 ' value='1521921'   \/><label for='answer-id-1521921' id='answer-label-1521921' class=' answer'><span>SED and SmartLock Compliance mode<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-23' style=';'><div id='questionWrap-23'  class='   watupro-question-id-391386'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>23. <\/span>Which iDRAC menu includes the detailed log files required to troubleshoot a hardware issue on a Dell EMC PowerEdge server?<\/div><input type='hidden' name='question_id[]' id='qID_23' value='391386' \/><input type='hidden' id='answerType391386' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391386[]' id='answer-id-1521922' class='answer   answerof-391386 ' value='1521922'   \/><label for='answer-id-1521922' id='answer-label-1521922' class=' answer'><span>Diagnostics<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391386[]' id='answer-id-1521923' class='answer   answerof-391386 ' value='1521923'   \/><label for='answer-id-1521923' id='answer-label-1521923' class=' answer'><span>Maintenance<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391386[]' id='answer-id-1521924' class='answer   answerof-391386 ' value='1521924'   \/><label for='answer-id-1521924' id='answer-label-1521924' class=' answer'><span>Troubleshooting<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391386[]' id='answer-id-1521925' class='answer   answerof-391386 ' value='1521925'   \/><label for='answer-id-1521925' id='answer-label-1521925' class=' answer'><span>System<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-24' style=';'><div id='questionWrap-24'  class='   watupro-question-id-391387'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>24. <\/span>A technician needs to set a server to always attempt PXE boot before booting to the hard drive. <br \/>\r<br>What two items does the technician need to set to achieve this? (Choose two.)<\/div><input type='hidden' name='question_id[]' id='qID_24' value='391387' \/><input type='hidden' id='answerType391387' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391387[]' id='answer-id-1521926' class='answer   answerof-391387 ' value='1521926'   \/><label for='answer-id-1521926' id='answer-label-1521926' class=' answer'><span>Remove all boot options except network card<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391387[]' id='answer-id-1521927' class='answer   answerof-391387 ' value='1521927'   \/><label for='answer-id-1521927' id='answer-label-1521927' class=' answer'><span>Select PXE Boot from F11 Boot Manager<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391387[]' id='answer-id-1521928' class='answer   answerof-391387 ' value='1521928'   \/><label for='answer-id-1521928' id='answer-label-1521928' class=' answer'><span>Change the Boot Sequence so the network card is first<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391387[]' id='answer-id-1521929' class='answer   answerof-391387 ' value='1521929'   \/><label for='answer-id-1521929' id='answer-label-1521929' class=' answer'><span>Set the Legacy Boot Protocol for the network card to PXE<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-25' style=';'><div id='questionWrap-25'  class='   watupro-question-id-391388'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>25. <\/span>An existing server is transferred to a new location. The technician is directed to change the information displayed on the LCD located on the front bezel to show the ambient temperature. <br \/>\r<br>What is a consideration for the technician?<\/div><input type='hidden' name='question_id[]' id='qID_25' value='391388' \/><input type='hidden' id='answerType391388' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391388[]' id='answer-id-1521930' class='answer   answerof-391388 ' value='1521930'   \/><label for='answer-id-1521930' id='answer-label-1521930' class=' answer'><span>LCD information can be configured for displaying ambient temperature using the iDRAC GU<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391388[]' id='answer-id-1521931' class='answer   answerof-391388 ' value='1521931'   \/><label for='answer-id-1521931' id='answer-label-1521931' class=' answer'><span>iDRAC Enterprise license must be installed to allow the LCD information to be changed.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391388[]' id='answer-id-1521932' class='answer   answerof-391388 ' value='1521932'   \/><label for='answer-id-1521932' id='answer-label-1521932' class=' answer'><span>Ambient temperature information cannot be displayed on the LC<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391388[]' id='answer-id-1521933' class='answer   answerof-391388 ' value='1521933'   \/><label for='answer-id-1521933' id='answer-label-1521933' class=' answer'><span>LCD information can only be configured to display the Service Tag and any errors that occur.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-26' style=';'><div id='questionWrap-26'  class='   watupro-question-id-391389'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>26. <\/span>Refer to the exhibit. <br \/>\r<br><br><img decoding=\"async\" width=428 height=599 id=\"\u56fe\u7247 59\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/uploads\/2025\/04\/image009.gif\"><br><br \/>\r<br>A system administrator wants to monitor information about the system using their smartphone and a Bluetooth connection. LED labeled 3 on the control panel is solid white. <br \/>\r<br>What does the LED indicate?<\/div><input type='hidden' name='question_id[]' id='qID_26' value='391389' \/><input type='hidden' id='answerType391389' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391389[]' id='answer-id-1521934' class='answer   answerof-391389 ' value='1521934'   \/><label for='answer-id-1521934' id='answer-label-1521934' class=' answer'><span>The system is powered on.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391389[]' id='answer-id-1521935' class='answer   answerof-391389 ' value='1521935'   \/><label for='answer-id-1521935' id='answer-label-1521935' class=' answer'><span>Quick SYNC 2 is ready to communicate.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391389[]' id='answer-id-1521936' class='answer   answerof-391389 ' value='1521936'   \/><label for='answer-id-1521936' id='answer-label-1521936' class=' answer'><span>OMM is transferring data.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391389[]' id='answer-id-1521937' class='answer   answerof-391389 ' value='1521937'   \/><label for='answer-id-1521937' id='answer-label-1521937' class=' answer'><span>The system is in failsafe mode.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-27' style=';'><div id='questionWrap-27'  class='   watupro-question-id-391390'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>27. <\/span>What does OBPAR allow on a PowerEdge MX750c?<\/div><input type='hidden' name='question_id[]' id='qID_27' value='391390' \/><input type='hidden' id='answerType391390' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391390[]' id='answer-id-1521938' class='answer   answerof-391390 ' value='1521938'   \/><label for='answer-id-1521938' id='answer-label-1521938' class=' answer'><span>Run a compute sled with memory overclocking.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391390[]' id='answer-id-1521939' class='answer   answerof-391390 ' value='1521939'   \/><label for='answer-id-1521939' id='answer-label-1521939' class=' answer'><span>Boot a compute sled with only one CP<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391390[]' id='answer-id-1521940' class='answer   answerof-391390 ' value='1521940'   \/><label for='answer-id-1521940' id='answer-label-1521940' class=' answer'><span>Run a compute sled with maximum performance.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391390[]' id='answer-id-1521941' class='answer   answerof-391390 ' value='1521941'   \/><label for='answer-id-1521941' id='answer-label-1521941' class=' answer'><span>Boot a compute sled with reduced frequency.<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-28' style=';'><div id='questionWrap-28'  class='   watupro-question-id-391391'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>28. <\/span>A company's servers were ordered with iDRAC Enterprise with vFlash. The server profile was backed up after the first boot. Changes have been made to the server BIOS settings and firmware versions, which have resulted in many performance issues. <br \/>\r<br>What is the most efficient way for the technician to address the performance issues?<\/div><input type='hidden' name='question_id[]' id='qID_28' value='391391' \/><input type='hidden' id='answerType391391' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391391[]' id='answer-id-1521942' class='answer   answerof-391391 ' value='1521942'   \/><label for='answer-id-1521942' id='answer-label-1521942' class=' answer'><span>Upload the approved corporate firmware versions from the file share<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391391[]' id='answer-id-1521943' class='answer   answerof-391391 ' value='1521943'   \/><label for='answer-id-1521943' id='answer-label-1521943' class=' answer'><span>Restore system profile using the iDRAC or Lifecycle Controller<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391391[]' id='answer-id-1521944' class='answer   answerof-391391 ' value='1521944'   \/><label for='answer-id-1521944' id='answer-label-1521944' class=' answer'><span>Run the racadm racresetcfg command to reset all server settings<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391391[]' id='answer-id-1521945' class='answer   answerof-391391 ' value='1521945'   \/><label for='answer-id-1521945' id='answer-label-1521945' class=' answer'><span>Reboot the server to F10 and perform System Repurpose\/Retire<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-29' style=';'><div id='questionWrap-29'  class='   watupro-question-id-391392'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>29. <\/span>A technician resets the iDRAC but when they attempt to log back in to the iDRAC is offline. <br \/>\r<br>Why is the iDRAC offline?<\/div><input type='hidden' name='question_id[]' id='qID_29' value='391392' \/><input type='hidden' id='answerType391392' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391392[]' id='answer-id-1521946' class='answer   answerof-391392 ' value='1521946'   \/><label for='answer-id-1521946' id='answer-label-1521946' class=' answer'><span>DRAC has reset to the default IP address of 192.168.0.120<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391392[]' id='answer-id-1521947' class='answer   answerof-391392 ' value='1521947'   \/><label for='answer-id-1521947' id='answer-label-1521947' class=' answer'><span>Technician must use iDRAC Direct to enable the iDRAC network<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391392[]' id='answer-id-1521948' class='answer   answerof-391392 ' value='1521948'   \/><label for='answer-id-1521948' id='answer-label-1521948' class=' answer'><span>iDRAC is still in the reset process<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391392[]' id='answer-id-1521949' class='answer   answerof-391392 ' value='1521949'   \/><label for='answer-id-1521949' id='answer-label-1521949' class=' answer'><span>Technician must move the iDRAC network cable back to the iDRAC dedicated NIC<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-30' style=';'><div id='questionWrap-30'  class='   watupro-question-id-391393'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>30. <\/span>A technician has the ISO image of an OS that they need to install on a server in a remote location. They are already logged into the iDRAC. <br \/>\r<br>How should the technician install the OS?<\/div><input type='hidden' name='question_id[]' id='qID_30' value='391393' \/><input type='hidden' id='answerType391393' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391393[]' id='answer-id-1521950' class='answer   answerof-391393 ' value='1521950'   \/><label for='answer-id-1521950' id='answer-label-1521950' class=' answer'><span>Click Launch under the Virtual Console Preview, Select Next Boot, and choose Virtual CD\/DVD\/ISO<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391393[]' id='answer-id-1521951' class='answer   answerof-391393 ' value='1521951'   \/><label for='answer-id-1521951' id='answer-label-1521951' class=' answer'><span>Click Launch under the Virtual Console Preview and then connect to Virtual Media<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391393[]' id='answer-id-1521952' class='answer   answerof-391393 ' value='1521952'   \/><label for='answer-id-1521952' id='answer-label-1521952' class=' answer'><span>Click Launch under the Virtual Console Preview, reboot the server into F10, and start the Lifecycle Controller OS Deployment wizard<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391393[]' id='answer-id-1521953' class='answer   answerof-391393 ' value='1521953'   \/><label for='answer-id-1521953' id='answer-label-1521953' class=' answer'><span>Click on Update and Rollback under Quick Launch Tasks<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-31' style=';'><div id='questionWrap-31'  class='   watupro-question-id-391394'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>31. <\/span>From PERC8 to PERC9, the maximum number of individual drives upon which a virtual disk can be created changed. <br \/>\r<br>How did this value change?<\/div><input type='hidden' name='question_id[]' id='qID_31' value='391394' \/><input type='hidden' id='answerType391394' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391394[]' id='answer-id-1521954' class='answer   answerof-391394 ' value='1521954'   \/><label for='answer-id-1521954' id='answer-label-1521954' class=' answer'><span>8 to 32<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391394[]' id='answer-id-1521955' class='answer   answerof-391394 ' value='1521955'   \/><label for='answer-id-1521955' id='answer-label-1521955' class=' answer'><span>16 to 64<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391394[]' id='answer-id-1521956' class='answer   answerof-391394 ' value='1521956'   \/><label for='answer-id-1521956' id='answer-label-1521956' class=' answer'><span>16 to 32<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391394[]' id='answer-id-1521957' class='answer   answerof-391394 ' value='1521957'   \/><label for='answer-id-1521957' id='answer-label-1521957' class=' answer'><span>8 to 16<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-32' style=';'><div id='questionWrap-32'  class='   watupro-question-id-391395'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>32. <\/span>A user has a number of PowerEdge servers and installs OME on a remote system to monitor the servers. When attempting to discover one of the servers, the discovery process is unsuccessful. The user accesses the Troubleshooting tool to establish that the communication pathway is correct. <br \/>\r<br>After entering the server iDRAC IP address, which network protocol should be selected to communicate with the iDRAC?<\/div><input type='hidden' name='question_id[]' id='qID_32' value='391395' \/><input type='hidden' id='answerType391395' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391395[]' id='answer-id-1521958' class='answer   answerof-391395 ' value='1521958'   \/><label for='answer-id-1521958' id='answer-label-1521958' class=' answer'><span>SNMP<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391395[]' id='answer-id-1521959' class='answer   answerof-391395 ' value='1521959'   \/><label for='answer-id-1521959' id='answer-label-1521959' class=' answer'><span>IPMI<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391395[]' id='answer-id-1521960' class='answer   answerof-391395 ' value='1521960'   \/><label for='answer-id-1521960' id='answer-label-1521960' class=' answer'><span>In-Band<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391395[]' id='answer-id-1521961' class='answer   answerof-391395 ' value='1521961'   \/><label for='answer-id-1521961' id='answer-label-1521961' class=' answer'><span>WS-MAN<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-33' style=';'><div id='questionWrap-33'  class='   watupro-question-id-391396'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>33. <\/span>A technician is tasked to perform a RAID Level Migration (RLM) of a RAID 5 array to a RAID 6 array. They back up data and look in iDRAC Storage and find that the current RAID 5 array is sliced into two virtual disks. <br \/>\r<br>What should the technician do to achieve the desired RAID level?<\/div><input type='hidden' name='question_id[]' id='qID_33' value='391396' \/><input type='hidden' id='answerType391396' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391396[]' id='answer-id-1521962' class='answer   answerof-391396 ' value='1521962'   \/><label for='answer-id-1521962' id='answer-label-1521962' class=' answer'><span>Reboot and press Ctrl-R to complete RAID migration<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391396[]' id='answer-id-1521963' class='answer   answerof-391396 ' value='1521963'   \/><label for='answer-id-1521963' id='answer-label-1521963' class=' answer'><span>Use iDRAC GUI under Storage Configuration to delete the arrays and recreate the new RAID 6 array<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391396[]' id='answer-id-1521964' class='answer   answerof-391396 ' value='1521964'   \/><label for='answer-id-1521964' id='answer-label-1521964' class=' answer'><span>Open the OpenManage Enterprise GUI, delete the arrays, and recreate the new RAID 6 array<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391396[]' id='answer-id-1521965' class='answer   answerof-391396 ' value='1521965'   \/><label for='answer-id-1521965' id='answer-label-1521965' class=' answer'><span>Use SupportAssist Enterprise to complete RAID migration<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-34' style=';'><div id='questionWrap-34'  class='   watupro-question-id-391397'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>34. <\/span>A technician needs to initially configure a server from a bare metal condition in the following areas: <br \/>\r<br>- Processor settings <br \/>\r<br>- Disk configuration <br \/>\r<br>- iDRAC network settings <br \/>\r<br>The technician can only reboot once to achieve these tasks. <br \/>\r<br>Where should the technician configure these settings? (Choose three.)<\/div><input type='hidden' name='question_id[]' id='qID_34' value='391397' \/><input type='hidden' id='answerType391397' value='checkbox'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391397[]' id='answer-id-1521966' class='answer   answerof-391397 ' value='1521966'   \/><label for='answer-id-1521966' id='answer-label-1521966' class=' answer'><span>PXE Settings<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391397[]' id='answer-id-1521967' class='answer   answerof-391397 ' value='1521967'   \/><label for='answer-id-1521967' id='answer-label-1521967' class=' answer'><span>System BIOS<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391397[]' id='answer-id-1521968' class='answer   answerof-391397 ' value='1521968'   \/><label for='answer-id-1521968' id='answer-label-1521968' class=' answer'><span>PERC Configuration Utility<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391397[]' id='answer-id-1521969' class='answer   answerof-391397 ' value='1521969'   \/><label for='answer-id-1521969' id='answer-label-1521969' class=' answer'><span>iDRAC Settings<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='checkbox' name='answer-391397[]' id='answer-id-1521970' class='answer   answerof-391397 ' value='1521970'   \/><label for='answer-id-1521970' id='answer-label-1521970' class=' answer'><span>Device Settings<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-35' style=';'><div id='questionWrap-35'  class='   watupro-question-id-391398'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>35. <\/span>Which characteristic of system management enables a company to reduce costs?<\/div><input type='hidden' name='question_id[]' id='qID_35' value='391398' \/><input type='hidden' id='answerType391398' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391398[]' id='answer-id-1521971' class='answer   answerof-391398 ' value='1521971'   \/><label for='answer-id-1521971' id='answer-label-1521971' class=' answer'><span>Integration with third-party tools<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391398[]' id='answer-id-1521972' class='answer   answerof-391398 ' value='1521972'   \/><label for='answer-id-1521972' id='answer-label-1521972' class=' answer'><span>Multi-tenancy support<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391398[]' id='answer-id-1521973' class='answer   answerof-391398 ' value='1521973'   \/><label for='answer-id-1521973' id='answer-label-1521973' class=' answer'><span>Rich management interface<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391398[]' id='answer-id-1521974' class='answer   answerof-391398 ' value='1521974'   \/><label for='answer-id-1521974' id='answer-label-1521974' class=' answer'><span>Automation of routine tasks<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-36' style=';'><div id='questionWrap-36'  class='   watupro-question-id-391399'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>36. <\/span>On a PowerEdge R640 server, the System Lockdown mode has been enabled. Certain features are no longer available in the System BIOS utility or IDRAC GUI. <br \/>\r<br>Which other feature is no longer available?<\/div><input type='hidden' name='question_id[]' id='qID_36' value='391399' \/><input type='hidden' id='answerType391399' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391399[]' id='answer-id-1521975' class='answer   answerof-391399 ' value='1521975'   \/><label for='answer-id-1521975' id='answer-label-1521975' class=' answer'><span>OMSA<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391399[]' id='answer-id-1521976' class='answer   answerof-391399 ' value='1521976'   \/><label for='answer-id-1521976' id='answer-label-1521976' class=' answer'><span>Lifecycle Controller<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391399[]' id='answer-id-1521977' class='answer   answerof-391399 ' value='1521977'   \/><label for='answer-id-1521977' id='answer-label-1521977' class=' answer'><span>iSM<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391399[]' id='answer-id-1521978' class='answer   answerof-391399 ' value='1521978'   \/><label for='answer-id-1521978' id='answer-label-1521978' class=' answer'><span>Booting to a 32-bit OS<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-37' style=';'><div id='questionWrap-37'  class='   watupro-question-id-391400'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>37. <\/span>A system administrator is trying to connect with a mobile device to a Dell PowerEdge 16G server using Quick Sync 2. They failed to make a connection. <br \/>\r<br>What is the reason for the failure?<\/div><input type='hidden' name='question_id[]' id='qID_37' value='391400' \/><input type='hidden' id='answerType391400' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391400[]' id='answer-id-1521979' class='answer   answerof-391400 ' value='1521979'   \/><label for='answer-id-1521979' id='answer-label-1521979' class=' answer'><span>Bluetooth is disabled on the mobile device.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391400[]' id='answer-id-1521980' class='answer   answerof-391400 ' value='1521980'   \/><label for='answer-id-1521980' id='answer-label-1521980' class=' answer'><span>NFC is disabled on the mobile device.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391400[]' id='answer-id-1521981' class='answer   answerof-391400 ' value='1521981'   \/><label for='answer-id-1521981' id='answer-label-1521981' class=' answer'><span>There is no iDRAC IP address configured.<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391400[]' id='answer-id-1521982' class='answer   answerof-391400 ' value='1521982'   \/><label for='answer-id-1521982' id='answer-label-1521982' class=' answer'><span>The mobile device is using iO<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-38' style=';'><div id='questionWrap-38'  class='   watupro-question-id-391401'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>38. <\/span>An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state. <br \/>\r<br>What task should be completed to troubleshoot this issue?<\/div><input type='hidden' name='question_id[]' id='qID_38' value='391401' \/><input type='hidden' id='answerType391401' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391401[]' id='answer-id-1521983' class='answer   answerof-391401 ' value='1521983'   \/><label for='answer-id-1521983' id='answer-label-1521983' class=' answer'><span>Confirm the System Input Power CAP is not set to Low<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391401[]' id='answer-id-1521984' class='answer   answerof-391401 ' value='1521984'   \/><label for='answer-id-1521984' id='answer-label-1521984' class=' answer'><span>Set the PSU AC redundancy to 1+1<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391401[]' id='answer-id-1521985' class='answer   answerof-391401 ' value='1521985'   \/><label for='answer-id-1521985' id='answer-label-1521985' class=' answer'><span>Set the PSU AC redundancy to 1+0<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391401[]' id='answer-id-1521986' class='answer   answerof-391401 ' value='1521986'   \/><label for='answer-id-1521986' id='answer-label-1521986' class=' answer'><span>Verify the new PSU is the same type and wattage rating<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-39' style=';'><div id='questionWrap-39'  class='   watupro-question-id-391402'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>39. <\/span>A new server with default iDRAC network configurations is plugged into a segregated management network configured for 10.0.0.x\/24. The technician cannot connect to the iDRAC. <br \/>\r<br>How can the on-site technician configure the iDRAC for network access?<\/div><input type='hidden' name='question_id[]' id='qID_39' value='391402' \/><input type='hidden' id='answerType391402' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391402[]' id='answer-id-1521987' class='answer   answerof-391402 ' value='1521987'   \/><label for='answer-id-1521987' id='answer-label-1521987' class=' answer'><span>Change iDRAC network settings from a workstation on the management network<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391402[]' id='answer-id-1521988' class='answer   answerof-391402 ' value='1521988'   \/><label for='answer-id-1521988' id='answer-label-1521988' class=' answer'><span>Perform an AC power cycle to reset the iDRAC<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391402[]' id='answer-id-1521989' class='answer   answerof-391402 ' value='1521989'   \/><label for='answer-id-1521989' id='answer-label-1521989' class=' answer'><span>Modify the iDRAC settings using the iDRAC Direct feature<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391402[]' id='answer-id-1521990' class='answer   answerof-391402 ' value='1521990'   \/><label for='answer-id-1521990' id='answer-label-1521990' class=' answer'><span>Configure a DHCP reservation for the iDRAC MAC address<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div class='watu-question ' id='question-40' style=';'><div id='questionWrap-40'  class='   watupro-question-id-391403'>\n\t\t\t<div class='question-content'><div><span class='watupro_num'>40. <\/span>A technician is deploying a server. <br \/>\r<br>What should they do once the server is fully configured and deployed?<\/div><input type='hidden' name='question_id[]' id='qID_40' value='391403' \/><input type='hidden' id='answerType391403' value='radio'><!-- end question-content--><\/div><div class='question-choices watupro-choices-columns '><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391403[]' id='answer-id-1521991' class='answer   answerof-391403 ' value='1521991'   \/><label for='answer-id-1521991' id='answer-label-1521991' class=' answer'><span>Switch on write-protect for the vFlash SD card<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391403[]' id='answer-id-1521992' class='answer   answerof-391403 ' value='1521992'   \/><label for='answer-id-1521992' id='answer-label-1521992' class=' answer'><span>Back up the server profile and reset the iDRAC to Default Settings<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391403[]' id='answer-id-1521993' class='answer   answerof-391403 ' value='1521993'   \/><label for='answer-id-1521993' id='answer-label-1521993' class=' answer'><span>Back up the server profile and configure the Parts Replacement feature<\/span><\/label><\/div><div class='watupro-question-choice  ' dir='auto' ><input type='radio' name='answer-391403[]' id='answer-id-1521994' class='answer   answerof-391403 ' value='1521994'   \/><label for='answer-id-1521994' id='answer-label-1521994' class=' answer'><span>Change the iDRAC secure password based on the users\u2019 company policies<\/span><\/label><\/div><!-- end question-choices--><\/div><!-- end questionWrap--><\/div><\/div><div style='display:none' id='question-41'>\n\t<div class='question-content'>\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/img\/loading.gif\" width=\"16\" height=\"16\" alt=\"Loading...\" title=\"Loading...\" \/>&nbsp;Loading...\t<\/div>\n<\/div>\n\n<br \/>\n\t\n\t\t\t<div class=\"watupro_buttons flex \" id=\"watuPROButtons9812\" >\n\t\t  <div id=\"prev-question\" style=\"display:none;\"><input type=\"button\" value=\"&lt; Previous\" onclick=\"WatuPRO.nextQuestion(event, 'previous');\"\/><\/div>\t\t  \t\t  \t\t   \n\t\t   \t  \t\t<div><input type=\"button\" name=\"action\" class=\"watupro-submit-button\" onclick=\"WatuPRO.submitResult(event)\" id=\"action-button\" value=\"View Results\"  \/>\n\t\t<\/div>\n\t\t<\/div>\n\t\t\n\t<input type=\"hidden\" name=\"quiz_id\" value=\"9812\" id=\"watuPROExamID\"\/>\n\t<input type=\"hidden\" name=\"start_time\" id=\"startTime\" value=\"2026-04-30 00:19:22\" \/>\n\t<input type=\"hidden\" name=\"start_timestamp\" id=\"startTimeStamp\" value=\"1777508362\" \/>\n\t<input type=\"hidden\" name=\"question_ids\" value=\"\" \/>\n\t<input type=\"hidden\" name=\"watupro_questions\" value=\"391364:1521833,1521834,1521835,1521836 | 391365:1521837,1521838,1521839,1521840 | 391366:1521841,1521842,1521843,1521844 | 391367:1521845,1521846,1521847,1521848 | 391368:1521849,1521850,1521851,1521852 | 391369:1521853,1521854,1521855,1521856 | 391370:1521857,1521858,1521859,1521860 | 391371:1521861,1521862,1521863,1521864 | 391372:1521865,1521866,1521867,1521868 | 391373:1521869,1521870,1521871,1521872 | 391374:1521873,1521874,1521875,1521876 | 391375:1521877,1521878,1521879,1521880 | 391376:1521881,1521882,1521883,1521884 | 391377:1521885,1521886,1521887,1521888 | 391378:1521889,1521890,1521891,1521892 | 391379:1521893,1521894,1521895,1521896 | 391380:1521897,1521898,1521899,1521900 | 391381:1521901,1521902,1521903,1521904 | 391382:1521905,1521906,1521907,1521908 | 391383:1521909,1521910,1521911,1521912,1521913 | 391384:1521914,1521915,1521916,1521917 | 391385:1521918,1521919,1521920,1521921 | 391386:1521922,1521923,1521924,1521925 | 391387:1521926,1521927,1521928,1521929 | 391388:1521930,1521931,1521932,1521933 | 391389:1521934,1521935,1521936,1521937 | 391390:1521938,1521939,1521940,1521941 | 391391:1521942,1521943,1521944,1521945 | 391392:1521946,1521947,1521948,1521949 | 391393:1521950,1521951,1521952,1521953 | 391394:1521954,1521955,1521956,1521957 | 391395:1521958,1521959,1521960,1521961 | 391396:1521962,1521963,1521964,1521965 | 391397:1521966,1521967,1521968,1521969,1521970 | 391398:1521971,1521972,1521973,1521974 | 391399:1521975,1521976,1521977,1521978 | 391400:1521979,1521980,1521981,1521982 | 391401:1521983,1521984,1521985,1521986 | 391402:1521987,1521988,1521989,1521990 | 391403:1521991,1521992,1521993,1521994\" \/>\n\t<input type=\"hidden\" name=\"no_ajax\" value=\"0\">\t\t\t<\/form>\n\t<p>&nbsp;<\/p>\n<\/div>\n\n<script type=\"text\/javascript\">\n\/\/jQuery(document).ready(function(){\ndocument.addEventListener(\"DOMContentLoaded\", function(event) { \t\nvar question_ids = \"391364,391365,391366,391367,391368,391369,391370,391371,391372,391373,391374,391375,391376,391377,391378,391379,391380,391381,391382,391383,391384,391385,391386,391387,391388,391389,391390,391391,391392,391393,391394,391395,391396,391397,391398,391399,391400,391401,391402,391403\";\nWatuPROSettings[9812] = {};\nWatuPRO.qArr = question_ids.split(',');\nWatuPRO.exam_id = 9812;\t    \nWatuPRO.post_id = 112389;\nWatuPRO.store_progress = 0;\nWatuPRO.curCatPage = 1;\nWatuPRO.requiredIDs=\"0\".split(\",\");\nWatuPRO.hAppID = \"0.01022900 1777508362\";\nvar url = \"https:\/\/www.dumpsbase.com\/freedumps\/wp-content\/plugins\/watupro\/show_exam.php\";\nWatuPRO.examMode = 1;\nWatuPRO.siteURL=\"https:\/\/www.dumpsbase.com\/freedumps\/wp-admin\/admin-ajax.php\";\nWatuPRO.emailIsNotRequired = 0;\nWatuPROIntel.init(9812);\nWatuPRO.inCategoryPages=1;});    \t \n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>DumpsBase offers Dell D-PE-OE-23 dumps (V9.02) to be your reliable study materials, which help you pass the Dell Technologies PowerEdge Operate 2023 exam on the first attempt. The dumps contain real questions and verified answers with a 100% success guarantee, making your exam pass smoother. If you want to check the quality of the dumps, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[125,16614],"tags":[18782,20135],"class_list":["post-112389","post","type-post","status-publish","format-standard","hentry","category-dell-emc","category-dell-server","tag-d-pe-oe-23-dumps","tag-dell-technologies-poweredge-operate-certification"],"_links":{"self":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/112389","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/comments?post=112389"}],"version-history":[{"count":1,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/112389\/revisions"}],"predecessor-version":[{"id":112390,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/posts\/112389\/revisions\/112390"}],"wp:attachment":[{"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/media?parent=112389"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/categories?post=112389"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dumpsbase.com\/freedumps\/wp-json\/wp\/v2\/tags?post=112389"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}